Camden Door Controls -CX-12 Switching Network

DOWNLOADS

Camden‘s CX-12 switching network has been designed for high reliability, improved security and easy installation. The controller operates as a make/break relay and as a bi-directional door sequencer, for control of two automatic door operators, with 3 adjustable time/delays.


Category: low-voltage controls | relay controls | relay logic controllers...

MasterFormat: Special Function Hardware | Instrumentation and Control for Electrical Systems | Electrical Controls and Relays...



Camden Door Controls
6-5151 Everest Drive
Mississauga, ON L4W 2Z3
Tel: (877) 226-3369

csr@camdencontrols.com

https://www.camdencontrols.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


CX-12 Switching Network

Camden‘s CX-12 switching network has been designed for high reliability, improved security and easy installation. The controller operates as a make/break relay and as a bi-directional door sequencer, for control of two automatic door operators, with 3 adjustable time/delays. Applications: Ideal for automatic door applications with momentary or maintained inputs, with an input for connection to telephone entry systems and fire alarm systems.

The CX-12 Performs two functions:

Switching Network

(De) energize electric locks (including magnetic locks or electric strikes) and activate automatic door operator with adjustable time delays. Extend trigger to maintain signal to door operators in EVAC door applications. Simplify wiring in telephone entry applications by eliminating the need for an isolating relay (to switch)

Bi-Directional Door Sequencer

Sequence two automatic doors in both directions. A typical application is controlling two vestibule doors, with sequential (time delayed) opening upon activation of both an exterior and interior door control switch.

Features
  • Bi-directional sequencing Mode

  • 3 adjustable delays, up to 30 seconds max.

  • LED's for visual display

  • Accepts wet or dry inputs

  • 12/24 V AC/DC operation

  • SPDT contacts rated 3 AMPS @ 30V DC

  • Input for connection to telephone entry system

  • One shot design for security

  • Maintained output for smoke EVAC

  • Easily mounted with double side tape or fasteners

  • 3 year warranty


See More


Specifications

Specifications
Voltage:12 - 24V AC/DC
Current Draw:20mA Idle, 60mA Operating
Response Time:.3 Seconds
Input:2 Wet + 2 Dry, N/O
Operation:One Shot, Maintained, or Sequencing
Output:2 x Form 'C' (SPDT)
Contact Rating:3A@30V DC
Electrical Life:100,000 @ Rated Capacity
Time Delay:D.O.R. #1: 1-30 Seconds
D.O.O. #2: 1-30 Seconds
D.O.R. #2: 1-30 Seconds
Dimensions:3 1/4"L x 2 1/4"W x 3/4"H
(83mm x 57mm x 19mm)
MODELS
ModelDescription
CX-12Switching Network

Dimensions: 9.00"L x 5.00"W x 1.00"H

Weight: 0.22lbs.

UPC:670454160522