Mitsubishi Electric HVAC-Proposed - MSZ - M-Series Heat Pumps - Indoor Units (Multi Zone)-0_MSZ-GE06NA-8 (Old Model)

MSZ - M-Series Heat Pumps - Indoor Units (Multi Zone)-0_MSZ-GE06NA-8 (Old Model)


MasterFormat: Central HVAC Equipment | Decentralized Unitary HVAC Equipment | Air-Source Unitary Heat Pumps...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



MSZ - M-Series Heat Pumps - Indoor Units (Multi Zone) - 0_MSZ-GE06NA-8 (Old Model)

MSZ - M-Series Heat Pumps - Indoor Units (Multi Zone)


Model Number: 0_MSZ-GE06NA-8 (Old Model)

Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEV's provide higher efficiency with controlled power usage. The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restored when power returns.


Sleek, flat panel design
Hot-start technology
Quiet operation
i-see Sensor technology available
Enhanced filtration system available
Hand-held wireless remote; optional MHK1 backlit wall-mounted wireless remote controller




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 9000 Btu/h (2.64 kW) *1
Cooling Capacity Range 2800 - 9000 BTU/h (0.8 - 2.6 kW)
Cooling Total Input 580 W (0.6 kW)
Cooling Energy Efficiency SEER 26
Cooling Sensible Heat Factor 0.76
Cooling Moisture Removal Pints/H 2.1
Cooling EER 15.5
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 3000 - 18000 Btu/h (0.9 - 5.3 kW)
Heating at 47° F Total Input 710 (150 - 2250) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 4.5
Heating at 17° F Maximum Capacity 12500 Btu/h (3.7 kW)
Heating at 17° F COP 3.02 Btu/Btu
Heating at 17° F Total Input 650 W
Heating at 17° F Rated Capacity 6700 Btu/h (2 kW) *3
Heating at 5° F Maximum Capacity 10900 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 162-226-339-381 CFM (4-6-9-10 m³/min)
Airflow Cooling : WET 144-202-307-343 CFM (4-6-9-10 m³/min)
Airflow Heating : WET 166-240-367-381 CFM (5-7-10-11 m³/min)
Sound Pressure Level Cooling 22-31-39-42 dB(A)
Sound Pressure Level Heating 22-31-40-42 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 10-1/8 Inches (257 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB, -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -13°F (-25°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Munsell 1.0Y 9.2 / 0.2

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 12000 Btu/h (3.52 kW) *1
Cooling Capacity Range 2800 - 12000 Btu/h (0.8 - 3.5 kW)
Cooling Total Input 930 W (0.9 kW)
Cooling Energy Efficiency SEER 23
Cooling Sensible Heat Factor 0.73
Cooling Moisture Removal Pints/H 2.9
Cooling EER 12.9
Heating at 47° F Rated Capacity 13600 Btu/h (4 kW) *2
Heating at 47° F Capacity Range 3000 - 21000 Btu/h (0.9 - 6.2 kW)
Heating at 47° F Total Input 950 (150 - 2250) W
Heating at 47° F HSPF (Region IV) 8.2
Heating at 47° F COP 4.2
Heating at 17° F Maximum Capacity 13600 Btu/h (4 kW)
Heating at 17° F COP 3.04 Btu/Btu
Heating at 17° F Rated Capacity 7900 Btu/h (2.3 kW) *3
Heating at 17° F Total Input 750 W
Heating at 5° F Maximum Capacity 13600 Btu/h (4 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 162-226-339-381 CFM (4-6-9-10 m³/min)
Airflow Cooling : WET 144-202-307-343 CFM (4-6-9 m³/min)
Airflow Heating : WET 166-240-367-381 CFM (5-7-10-11 m³/min)
Sound Pressure Level Heating 22-31-40-42 dB(A)
Sound Pressure Level Cooling 22-31-39-42 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 10-1/8 Inches (257 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 5/8 Inch (15.88 mm)
Field Drainpipe Size O.D. 5/8 Inch (16 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB, -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -13°F (-25°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 18000 Btu/h (5.28 kW) *1
Cooling Capacity Range 8200 - 25200 Btu/h (2.4 - 7.4 kW)
Cooling Total Input 1270 W (1.3 kW)
Cooling Energy Efficiency SEER 20.2
Cooling Sensible Heat Factor 0.84
Cooling Moisture Removal Pints/H 2.7
Cooling EER 14.2
Heating at 47° F Rated Capacity 21600 Btu/h (6.3 kW) *2
Heating at 47° F Capacity Range 7500 - 29700 Btu/h (2.2 - 8.7 kW)
Heating at 47° F Total Input 1540 (520 - 2240) W
Heating at 47° F HSPF (Region IV) 10.5
Heating at 47° F COP 4.11
Heating at 17° F Maximum Capacity 21600 Btu/h (6.3 kW)
Heating at 17° F COP 2.76 Btu/Btu
Heating at 17° F Rated Capacity 11700 Btu/h (3.4 kW) *3
Heating at 17° F Total Input 1240 W
Heating at 5° F Maximum Capacity 21600 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 162-226-381-410 CFM (4-6-10-11 m³/min)
Airflow Cooling : WET 144-202-350-367CFM (4-6-10-10 m³/min)
Airflow Heating : WET 166-240-399-420 CFM (5-7-11-12 m³/min)
Sound Pressure Level Cooling 22-33-43-45 dB(A)
Sound Pressure Level Heating 22-33-43-44 dB(A)
Dimensions H x W x D Height 12-13/16 Inches (325 mm)
Dimensions H x W x D Width 43-5/16 Inches (1,116 mm)
Dimensions H x W x D Depth 9-3/8 Inches (238 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (16 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB, -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -13°F (-25°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Defrost Method Reverse Cycle
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 6000 Btu/h (1.76 kW) *1
Heating at 47° F Rated Capacity 7200 Btu/h (2.1 kW) *2
Heating at 47° F HSPF (Region IV) 10
Maximum fuse size (time delay) MOCP 1 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 145-170-237-321-399 CFM (4-5-7-9 m³/min)
Airflow Cooling : WET 109-134-201-286-364CFM (3-4-6-8-10 m³/min)
Airflow Heating : WET 145-170-237-321-406 CFM (4-5-7-9-11 m³/min)
Sound Pressure Level Heating 19-22-30-37-43 dB(A)
Sound Pressure Level Cooling 19-22-30-37-43 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-7/16 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
External Finish Munsell 1.0Y 9.2 / 0.2


Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 9000 Btu/h (2.64 kW) *1
Cooling Capacity Range 3800 - 12200 Btu/h (1.1 - 3.6 kW)
Cooling Total Input 660 W (0.7 kW)
Cooling Energy Efficiency SEER 21
Cooling Sensible Heat Factor 0.82
Cooling Moisture Removal Pints/H 1.5
Cooling EER 13.6 1
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 4500 - 14100 Btu/h (1.3 - 4.1 kW)
Heating at 47° F Total Input 760 (255 - 1200) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 4.2
Heating at 17° F Maximum Capacity 8700 Btu/h (2.5 kW)
Heating at 17° F COP 2.76 Btu/Btu
Heating at 17° F Total Input 700 W
Heating at 17° F Rated Capacity 6600 Btu/h (1.9 kW) *3
Heating at 5° F Maximum Capacity 7061 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 145-170-237-321-399 CFM (4-5-7-9 m³/min)
Airflow Cooling : WET 109-134-201-286-364CFM (3-4-6-8-10 m³/min)
Airflow Heating : WET 145-170-233-321-406 CFM (4-5-7-9-11 m³/min)
Sound Pressure Level Cooling 19-22-30-37-43 dB(A)
Sound Pressure Level Heating 19-22-30-37-43 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Munsell 1.0Y 9.2 / 0.2

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 6000 Btu/h (1.76 kW) *1
Heating at 47° F Rated Capacity 7200 Btu/h (2.1 kW) *2
Heating at 47° F HSPF (Region IV) 10
Maximum fuse size (time delay) MOCP 1 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 145-170-237-321-399 CFM (4-5-7-9 m³/min)
Airflow Cooling : WET 109-134-201-286-364CFM (3-4-6-8-10 m³/min)
Airflow Heating : WET 145-170-237-321-406 CFM (4-5-7-9-11 m³/min)
Sound Pressure Level Heating 19-22-30-37-43 dB(A)
Sound Pressure Level Cooling 19-22-30-37-43 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-7/16 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
External Finish Munsell 1.0Y 9.2 / 0.2

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 12000 Btu/h (3.52 kW) *1
Cooling Capacity Range 3800 - 13600 Btu/h (1.1 - 4 kW)
Cooling Total Input 960 W (1 kW)
Cooling Energy Efficiency SEER 20.5
Cooling Sensible Heat Factor 0.74
Cooling EER 12.5
Cooling Moisture Removal Pints/H 2.5
Heating at 47° F Rated Capacity 14400 Btu/h (4.2 kW) *2
Heating at 47° F Capacity Range 5500 - 18100 Btu/h (1.6 - 5.3 kW)
Heating at 47° F Total Input 1170 (340 - 1660) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.6
Heating at 17° F Maximum Capacity 11200 Btu/h (3.3 kW)
Heating at 17° F COP 2.86 Btu/Btu
Heating at 17° F Rated Capacity 8800 Btu/h (2.6 kW) *3
Heating at 17° F Total Input 900 W
Heating at 5° F Maximum Capacity 9194 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 145-170-237-321-399 CFM (4-5-7-9 m³/min)
Airflow Cooling : WET 109-134-201-286-364CFM (3-4-6-8-10 m³/min)
Airflow Heating : WET 145-170-237-321-406 CFM (4-5-7-9-11 m³/min)
Sound Pressure Level Heating 19-22-30-37-43 dB(A)
Sound Pressure Level Cooling 19-22-30-37-45 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Energy Star System X
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 9000 Btu/h (2.64 kW) *1
Cooling Capacity Range 3800 - 12200 Btu/h (1.1 - 3.6 kW)
Cooling Total Input 660 W (0.7 kW)
Cooling Energy Efficiency SEER 21
Cooling Sensible Heat Factor 0.82
Cooling Moisture Removal Pints/H 1.5
Cooling EER 13.6
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 4500 - 14100 Btu/h (1.3 - 4.1 kW)
Heating at 47° F Total Input 760 (255 - 1200) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 4.2
Heating at 17° F Maximum Capacity 8700 Btu/h (2.5 kW)
Heating at 17° F COP 2.76 Btu/Btu
Heating at 17° F Rated Capacity 6600 Btu/h (1.9 kW) *3
Heating at 17° F Total Input 700 W
Heating at 5° F Maximum Capacity 7061 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 145-170-237-321-399 CFM (4-5-7-9 m³/min)
Airflow Cooling : WET 109-134-201-286-364 CFM (3-4-6-8-10 m³/min)
Airflow Heating : WET 145-170-233-321-406 CFM (4-5-7-9-11 m³/min)
Sound Pressure Level Cooling 19-22-30-37-43 dB(A)
Sound Pressure Level Heating 19-22-30-37-43 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 14000 Btu/h (4.1 kW) *1
Cooling Capacity Range 3100 - 18200 Btu/h (0.9 - 5.3 kW)
Cooling Total Input 1080 W (1.1 kW)
Cooling Energy Efficiency SEER 21
Cooling Sensible Heat Factor 0.8
Cooling Moisture Removal Pints/H 2.7
Cooling EER 13
Heating at 47° F Rated Capacity 18000 Btu/h (5.3 kW) *2
Heating at 47° F Capacity Range 4800 - 20900 Btu/h (1.4 - 6.1 kW)
Heating at 47° F Total Input 1600 (270 - 2010) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.3
Heating at 17° F Maximum Capacity 15900 Btu/h (4.7 kW)
Heating at 17° F COP 2.88 Btu/Btu
Heating at 17° F Total Input 1150 W
Heating at 17° F Rated Capacity 11300 Btu/h (3.3 kW) *3
Heating at 5° F Maximum Capacity 13022 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 205-272-335-420-533 CFM (6-7-9-12 m³/min)
Airflow Cooling : WET 170-237-300-385-498CFM (5-7-8-11-14 m³/min)
Airflow Heating : WET 205-247-304-367-463 CFM (6-7-9-10-13 m³/min)
Sound Pressure Level Cooling 26-32-38-44-49 dB(A)
Sound Pressure Level Heating 26-30-35-40-46 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Energy Star System X
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 14000 Btu/h (4.1 kW) *1
Cooling Capacity Range 3100 - 18200 Btu/h (0.9 - 5.3 kW)
Cooling Total Input 1080 W (1.1 kW)
Cooling Energy Efficiency SEER 21
Cooling Sensible Heat Factor 0.8
Cooling Moisture Removal Pints/H 2.7
Cooling EER 13
Heating at 47° F Rated Capacity 18000 Btu/h (5.3 kW) *2
Heating at 47° F Capacity Range 4800 - 20900 Btu/h (1.4 - 6.1 kW)
Heating at 47° F Total Input 1600 (270 - 2010) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.3
Heating at 17° F Maximum Capacity 15900 Btu/h (4.7 kW)
Heating at 17° F COP 2.88 Btu/Btu
Heating at 17° F Rated Capacity 11300 Btu/h (3.3 kW) *3
Heating at 17° F Total Input 1150 W
Heating at 5° F Maximum Capacity 13022 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 205-272-335-420-533 CFM (6-7-9-12 m³/min)
Airflow Cooling : WET 170-237-300-385-498 CFM (5-7-8-11-14 m³/min)
Airflow Heating : WET 205-247-304-367-463 CFM (6-7-9-10-13 m³/min)
Sound Pressure Level Cooling 26-32-38-44-49 dB(A)
Sound Pressure Level Heating 26-30-35-40-46 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 17200 Btu/h (5.04 kW) *1
Cooling Capacity Range 3700 - 18700 Btu/h (1.1 - 5.5 kW)
Cooling Total Input 1640 W (1.6 kW)
Cooling Energy Efficiency SEER 19.2
Cooling Sensible Heat Factor 0.71
Cooling Moisture Removal Pints/H 4.6
Cooling EER 10.5
Heating at 47° F Rated Capacity 21600 Btu/h (6.3 kW) *2
Heating at 47° F Capacity Range 3500 - 25200 Btu/h (1 - 7.4 kW)
Heating at 47° F Total Input 1900 (230 - 2680) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.32
Heating at 17° F Maximum Capacity 17200 Btu/h (5 kW)
Heating at 17° F COP 2.7 Btu/Btu
Heating at 17° F Rated Capacity 13400 Btu/h (3.9 kW) *3
Heating at 17° F Total Input 1450 W
Heating at 5° F Maximum Capacity 13562 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 230-275-339-420-533 CFM (6-8-9-12 m³/min)
Airflow Cooling : WET 194-240-304-385-498 CFM (5-7-8-11-14 m³/min)
Airflow Heating : WET 230-275-339-431-512 CFM (7-8-10-12-15 m³/min)
Sound Pressure Level Cooling 28-33-38-44-49 dB(A)
Sound Pressure Level Heating 28-33-38-44-49 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 9-1/8 Inches (232 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
External Finish Munsell 1.0Y 9.2 / 0.2

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 22500 Btu/h (6.59 kW) *1
Cooling Capacity Range 8200 - 31400 Btu/h (2.4 - 9.2 kW)
Cooling Total Input 1800 W (1.8 kW)
Cooling Energy Efficiency SEER 19
Cooling Sensible Heat Factor 0.75
Cooling Moisture Removal Pints/H 5.1
Cooling EER 12.5
Heating at 47° F Rated Capacity 27600 Btu/h (8.1 kW) *2
Heating at 47° F Capacity Range 7500 - 36900 Btu/h (2.2 - 10.8 kW)
Heating at 47° F Total Input 2340 (520 - 3650) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.46
Heating at 17° F Maximum Capacity 24600 Btu/h (7.2 kW)
Heating at 17° F COP 2.64 Btu/Btu
Heating at 17° F Rated Capacity 16000 Btu/h (4.7 kW) *3
Heating at 17° F Total Input 1770 W
Heating at 5° F Maximum Capacity 21160 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 388-469-628-738 CFM (11-13-17-20 m³/min)
Airflow Cooling : WET 347-420-562-661CFM (10-12-16 m³/min)
Airflow Heating : WET 388-469-628-738 CFM (11-13-18-21 m³/min)
Sound Pressure Level Cooling 34-41-49-53 dB(A)
Sound Pressure Level Heating 32-41-49-52 dB(A)
Dimensions H x W x D Height 12-13/16 Inches (325 mm)
Dimensions H x W x D Width 43-5/16 Inches (1,116 mm)
Dimensions H x W x D Depth 9-3/8 Inches (238 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (16 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com