Sarnatherm Roof Board H is a high‐density polyisocyanurate roof board
Sarnatherm® Roof Board H is a lightweight, high‐density polyisocyanurate roof board with coated glass facers. Sarnatherm® Roof Board H is suitable for use in new construction and recover roof applications with Sarnafil® or Sikaplan® roof membranes. The coated glass facers provide strong, smooth surfaces suitable for mechanically attached or adhered applications.
- Achieves a UL 790 Class A combustible deck assembly rating without the use of a fire-rated slip sheet or the presence of a fire barrier
- Lightweight for easy hoisting, staging and maneuvering
- High impact and flexural strength
- Easy scoring, cutting and snapping
- Improved coverage rates in adhered systems
- Contains no CFC’s, HCFCs
- Zero Ozone Depletion Potential (ODP)
- Virtually no Global Warming Potential (GWP)
- Recognized as resistant to mold growth
Usage
Used as a lightweight roof board in conventional roof assemblies
AREAS OF APPLICATION - New Roofs
- Recover Roofs
- Mechanically Attached Systems
- Adhered Systems
Advantages
- Achieves a UL 790 Class A combustible deck assembly rating without the use of a fire-rated slip sheet or the presence of a fire barrier
- Lightweight for easy hoisting, staging and maneuvering
- High impact and flexural strength
- Easy scoring, cutting and snapping
- Improved coverage rates in adhered systems
- Contains no CFC’s, HCFCs
- Zero Ozone Depletion Potential (ODP)
- Virtually no Global Warming Potential (GWP)
- Recognized as resistant to mold growth
Packaging
- 4 ft x 4 ft (1.2 m x 1.2 m), 5.5 lbs (2.5 kg) per board, 48 boards per bundle
- 4 ft x 8 ft (1.2 m x 2.4 m), 11 lbs (5 kg) per board, 45 boards per bundle (½ stack)
- 0.5" (12.7 mm) thickness
Colour
Off‐white core with off‐white/light tan facers
Product Details
Sustainability / Certifications / Approvals
APPROVALS / STANDARDS- ASTM C 1289, Type II, Class 4, Grade 1
- FM Approved
- UL Classified 790
- UL Certified for Canada
- Miami‐Dade County
- State of Florida
Product Information
Chemical BasePolyisocyanurate foam core with coated glass facers
Recycled Content9% Pre-consumer
Shelf LifeN/A
Storage ConditionsFactory‐applied packaging is intended only for protection during transit. When stored outdoors or on the job site, the insulation should be stacked on pallets at least 4" (102 mm) above ground level and completely covered with a weatherproof covering such as a tarpaulin.
The temporary factory‐applied packaging should be slit or removed to prevent accumulation of condensation. Refer to PIMA Technical Bulletin
#109: Storage and Handling Recommendations for Polyiso Roof Insulation.
Technical Information
Service Temperature260°F (126°C) or less
Application
Application Steps
APPLICATION INSTRUCTIONSSarnatherm® Roof Board H is installed by a Sika Authorized Applicator. Sarnatherm® Roof Board H may be installed by mechanical attachment to the roof deck with approved fasteners and insulation plates or by attachment with Sarnacol board adhesive depending on project requirements and specifications. Roof boards that have become wet or damaged should be removed and replaced with solid, dry roof boards.
Contact Sika Corporation - Roofing Technical Department regarding alternative methods of attachment.
See More
See Less