Sika Corporation -Polyurethane Sealants - Sikaflex®-15 LM

DOWNLOADS

High Performance, low-modulus elastomeric sealant

Sikaflex®-15 LM is a low-modulus, high-performance, 1-component, polyurethane-based, non-sag elastomeric
sealant. Meets Federal Specification TT-S-00230C, Type II, Class A; ASTM C-920, Type S, Grade


Category: door sealants | elastomeric sealants | elastomeric sealants...

MasterFormat: Joint Protection | Joint Sealants


Related Products

Overview


Polyurethane Sealants - Sikaflex®-15 LM

High Performance, low-modulus elastomeric sealant

Sikaflex®-15 LM is a low-modulus, high-performance, 1-component, polyurethane-based, non-sag elastomeric
sealant. Meets Federal Specification TT-S-00230C, Type II, Class A; ASTM C-920, Type S, Grade
NS, Class 100/50, use T, NT, G, A, O, M; Federal Specification for silicones - TT-S-001543 A, Type non-sag.
Tested in accordance with ASTM C-1382 for use in EIFS systems.

  • Low modulus of elasticity
  • Easy and ready to use
  • Eliminates time, effort, waste, and equipment clean-up
  • High elasticity - cures to a tough, durable, flexible consistency with exceptional cut and tear resistance
  • Stress relaxation
  • Very good adhesion - bonds to most construction materials without a primer
  • Very good resistance to weathering
  • Proven in tough climates around the world
  • Urethane-based, suggested by EPA for radon reduction
  • Can be painted
  • Jet fuel resistant
  • Proven in tough climates around the world
  • Non-leaching
  • Movement capability of +100/-50% (ASTM C 719)

Usage

  • Excellent for moving joints in vertical applications.
  • Suitable for use between similar as well as dissimilar materials.
  • Typical applications include joints in concrete panel and wall systems, around window and door frames, reglets, flashing, common roofing detail applications, etc.
  • Exceptional sealant choice for high-rise and facade applications where high movement capability is required.
  • 2- and 3-hour UL Fire Rated Joint System Nos. FF-S-0007, FF-S-0037, FW-S-0015, FW-S-0018, HW-S-0076, HW-S-0095, WW-S-0011 and WW-S-0060.
  • An effective sealant for use in Exterior Insulation Finish Systems (EIFS).

Advantages

  • Low modulus of elasticity
  • Easy and ready to use
  • Eliminates time, effort, waste, and equipment clean-up
  • High elasticity - cures to a tough, durable, flexible consistency with exceptional cut and tear resistance
  • Stress relaxation
  • Very good adhesion - bonds to most construction materials without a primer
  • Very good resistance to weathering
  • Proven in tough climates around the world
  • Urethane-based, suggested by EPA for radon reduction
  • Can be painted
  • Jet fuel resistant
  • Proven in tough climates around the world
  • Non-leaching
  • Movement capability of +100/-50% (ASTM C 719)

Packaging

10 fl. oz. cartridge, 12 cartridges per box

20 fl oz. foil pack, 20 foil packs per box

5 gallon pail

55 gallon drum

Color

White, Colonial White, Aluminum Gray, Limestone, Black, Dark Bronze, Capitol Tan, Off-White, Beige, Almond, Coping Stone, Aluminum Stone, Medium Bronze, Redwood Tan, Hartford Green and Stone. Special colors on request (min. volume).

Product Details

Product Information

Shelf Life

Sikaflex®-15 LM has a shelf life of 12 months for cartridges and foil packs and 6 months for pails and drums from the date of production, if it is stored in undamaged, original, sealed packaging, and if the storage conditions are met.

Storage Conditions

Sikaflex®-15 LM shall be stored in dry conditions, where it is protected from direct sunlight and at temperatures between +40 °F and +95 °F (+4 °C and +35 °C). Condition material to 65°-75°F before using.

Technical Information

Elastic Recovery

>80%

Chemical Resistance

Good resistance to water, diluted acids, and diluted alkalines. Not normally for fully immersed conditions. Consult Technical Service for specific data.

Service Temperature

−40 °F min. / +170 °F max. (−40 °C to +77 °C)

Application

Application Information

Ambient Air Temperature

+40 °C min. / +100 °F max. (+4 °C to +38 °C), min. 5 °F (3 °C) above dew point temperature

Sealants should be installed when substrates are at mid-range of their anticipated movement.

Substrate Temperature

+40 °C to +100 °F (+4 °C to +38 °C)
Sealants should be installed when substrates are at mid-range of their anticipated movement.

Cure Time

Tack-free time 2 to 6 hours (TT-S-00230C)
Tack-free to touch 3 hours
Final cure 7 to 10 days

Application Steps

SUBSTRATE PREPARATION

Clean all surfaces. Joint walls must be sound, clean, dry, frost-free, and free of oil and grease. Curing compound residues and any other foreign matters must be thoroughly removed. A roughened surface will also enhance bond. Install bond breaker tape or backer rod to prevent bond at base of joint.


See More


Specifications

Adhesion in Peel

Substrate

Peel Strength

Adhesion loss

Aluminium

25 lbs.

0%

Concrete30 lbs.0%

Glass

25 lbs.

0%

Coverage

10.1 oz Cartridge: Yield in Linear Feet

Width

Depth

Depth

Depth

¼"3/8"½"
¼"24.3
3/8"16.210.8
½"12.18.16.1
¾"8.15.44.0
1"3.0
1¼"2.4
1½"2.0

20 oz Cartridge: Yield in Linear Feet

Width

Depth

Depth

Depth

¼"

3/8"

½"

¼"

48.1

3/8"

32.1

21.4

½"24.116.012.0
¾"16.010.78.0
1"6.0
1¼"4.8
1½"4.0

1 Gallon: Yield in Linear Feet

Width

Depth

Depth

Depth

¼"

3/8"

½"

¼"307.9
3/8"205.3136.8
½"153.9102.677.0
¾"102.668.451.3
1"38.5
1¼"30.8
1½"25.7
Movement Capability

+100/-50%

(ASTM C 719)

Resistance to Weathering

0 (no cracks)

(ASTM C 793)

Shore A Hardness

~25 (after 21 days)

(ASTM C 661)

~25(after 28 days)(ISO 868)
Tensile Stress at Specified Elongation

~50psi at 100% elongation

(ASTM D 412)

Approvals / Standards