Flooring Primers & Moisture Barriers - Sika® Level-01 Primer Plus
Acrylic primer for porous substrates
Sika® Level-01 Primer Plus is a one-part, water-dispersed and solvent-free, acrylic-based solution used to prime and seal floor surfaces prior to the application of Sika® Level products.
- Water-based and solvent-free
- Penetrates substrate to reduce outgassing and formation of bubbles in the underlayment
- Prevents water loss from the underlayment into the substrate
- 10 minutes on concrete
- Effectively seals concrete surfaces in a single, economic operation
- Low VOC and low odor
- Interior and exterior use
Usage
- For absorbent substrates
- Concrete and cement screeds.
- Suitable on OSB and plywood
- Particularly suitable as an adhesion promoter and surface sealer beneath Sika Level products, enhancing the bond and integrity of the underlayment when applied onto porous substrates.
Advantages
- Water-based and solvent-free
- Penetrates substrate to reduce outgassing and formation of bubbles in the underlayment
- Prevents water loss from the underlayment into the substrate
- 10 minutes on concrete
- Effectively seals concrete surfaces in a single, economic operation
- Low VOC and low odor
- Interior and exterior use
Packaging
1 gal. (3.8 L) and 5 gal. (18.9 L) jugs
Color
White liquid
Product Details
Product Information
Shelf Life12 months in original, unopened container. Protect from high heat and freezing; if frozen, discard
Storage ConditionsStore dry at 41-77 °F (5-25 °C), if frozen, discard.
Condition material should be 65-75 °F (18-24 °C) before using.
Density62 lb./ft3
Solid content by weight30 %
Application
Application Information
Ambient Air Temperature50-95 °F (10-35 °C)
Relative Air HumidityMax 75 %
Substrate Temperature50-95 °F (10-35 °C)
Application Steps
MIXINGAPPLICATION- Apply with a stiff bristle, exploded tip push broom.
- Sika® does not recommend the use of paint rollers or spray equipment.
- When first applied, Sika® Level-01 Primer Plus appears white; once dry, it is clear. This facilitates quality control in terms of complete coverage and clearly confirms when the underlay can be installed
- Where temperatures exceed 86 °F (30 °C), refer to and follow ACI hot weather application and protection guidelines.
See More
See Less