Sika Corporation -Anchoring Adhesives - Sika AnchorFix®-2

DOWNLOADS

Super strength, two component adhesive anchoring system

Sika® AnchorFix-2 adhesive anchor system is solvent/styrene free, epoxy acrylate based, and has been specifically formulated as a high performance, two component adhesive anchor system for threaded bars in uncracked concrete.


Category: anchoring compounds | concrete adhesives | masonry adhesives...

MasterFormat: Common Work Results for Concrete | Cast-In-Place Concrete


Related Products

Overview


Anchoring Adhesives - Sika AnchorFix®-2

Super strength, two component adhesive anchoring system

Sika® AnchorFix-2 adhesive anchor system is solvent/styrene free, epoxy acrylate based, and has been specifically formulated as a high performance, two component adhesive anchor system for threaded bars in uncracked concrete.

  • Fast curing
  • Standard guns can be used
  • High load capacity
  • Drinking Water certified
  • Non-sag, even overhead
  • Styrene-free epoxy acrylate
  • Low wastage
  • Fixing close to free edges.
  • Versatile range of embedment depths.
  • Anchoring without expansion forces.

Usage

As a fast curing anchoring adhesive for all grades of:
  • Rebars / reinforcing steel
  • Threaded rods
  • Bolts and special fastening systems
In the following substrates:
  • Concrete
  • Solid masonry
  • Steel
  • Hard natural stone*
  • Solid rock*
* These substrates may vary greatly, in particular with regard to strength, composition and porosity. Therefore, for each application the suitability of Sika AnchorFix®-2 Adhesive must be tested by first applying the Product only to a sample area. Check in particular bond strength, surface staining and discoloration.

Advantages

  • Fast curing
  • Standard guns can be used
  • High load capacity
  • Drinking Water certified
  • Non-sag, even overhead
  • Styrene-free epoxy acrylate
  • Low wastage
  • Fixing close to free edges.
  • Versatile range of embedment depths.
  • Anchoring without expansion forces.

Packaging

10 fl.oz. (299 ml) cartridge

Color

uniform gray

Product Details

Sustainability / Certifications / Approvals

APPROVALS / STANDARDS
  • EESR to AC308 by ICC-ES PENDING.
  • ESR to AC308 by IAPMO-UES.
  • Certified to ANSI / NSF - 61 by UL.

Product Information

Shelf Life

12 months from date of production

All Sika AnchorFix®-2 cartridges have the expiry date printed on the label.

Storage Conditions

Cartridges should be stored in their original packaging, the correct way up, in cool conditions 41 °F to 77 °F (5 °C to 25 °C) out of direct sunlight.

System Information

Application

Application Information

Mixing Ratio

Component A : component B = 10 : 1 by volume

Sag Flow

Non-sag, even overhead

Product Temperature

Sika AnchorFix®-2 must be at a temperature of between 41 °F (5 °C) to 68 °F (20 °C) for application.

Dew Point
  • Beware of condensation.
  • Beware of frost.

Consumption

Application Steps

SUBSTRATE QUALITY

Mortar and concrete must be older than 28 days. Substrate strength (concrete, masonry, natural stone) must be verified. Pull-out tests must be carried out if the substrate strength is unknown. The anchor hole must always be clean, dry, free from oil and grease etc. Loose particles must be removed from the holes.
Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or any other substances and particles such as dirt etc.

CLEANING OF TOOLS

Tools must be cleaned as soon as possible with a clean rag.


See More


Specifications

MIXING

1. Unscrew the cap

2. Cut the film

3. Screw on the static mixer

4. Place the cartridge into the gun and start application

Open Time

Cartridge

Temperature

T Work (minutes)Base Material TemperatureT Load (hours)
Minimum 41°F-14 °F to 32 °F*24 hours
Minimum 41 °F-32 °F to 41°F180 minutes
41 °F to 50 °F841 °F to 50 °F100 minutes
50 °F to 68 °F450 °F to 68 °F70 minutes
68 °F to 77 °F368 °F to 77 °F40 minutes
77 °F to 86 °F277 °F to 86 °F40 minutes
86 °F186 °F40 minutes

T Work is the typical time to gel at the highest temperature in the range
T Load is the typical time to reach full capacity
* The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Service Temperature

Long term

40 °F (4 °C) min. / 122 °F (50 °C) max.

Short term (1-2 hours)

176 °F (80 °C)

System Structure

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Tensile Adhesion Strength
  1. The above values represent mean ultimate values and allowable working loads. The allowable working loads have been reduced using a safety factor of 4.0 for tension and 3.0 for shear, however, in some cases, such as life safety, safety factors of 10.0 or higher may be necessary.
  2. Allowable loads must be checked against steel capacity. The lowest value controls.
  3. Tabulated data is applicable to single anchors in normal weight concrete unaffected by edge or spacing reduction factors. Values are valid for anchors installed into dry concrete in holes drilled with a hammer drill and ANSI carbide drill bit.
  4. Service temperatures should remain approximately constant. The maximum long term temperature being 122 °F and the maximum short term temperature being 176 °F. Short term temperatures are those that occur over brief intervals, for example, diurnal cycling.
  5. Linear interpolation is allowed.

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Design Considerations

Allowable Tension, Nall = 0.33 x fu x nominal cross sectional area
Allowable Shear, Vall = 0.17 x fu x nominal cross section area
*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Tension = 0.33 x fu x nominal cross sectional area
Shear = 0.17 x fu x nominal cross section area

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Coverage

*Number of fixings assumes 30ml wastage in initial extrusion and holes filled to 3/4 full