SAFTI FIRST -SuperLite® II-XLM 60 - 60 Minute Fire Resistive Multilaminate Glazing

DOWNLOADS

60 Minute Fire Resistive Multilaminate Glazing


Category: 088100 | insulated glass | insulating glass...

MasterFormat: Door Louvers and Vision Lights | Fire-Rated Glass and Glazing Systems | Fire-Resistant Glazing...



SAFTI FIRST
100 N Hill Drive
Suite 12
Brisbane, CA 94005
Tel: (888) 653-3333
Fax: (415) 824-5900

info@safti.com

https://safti.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


SuperLite® II-XLM 60 - 60 Minute Fire Resistive Multilaminate Glazing

Product Advantages

  • Fire resistive multilaminate glazing offering maximum fire and safety with hose stream for 60 minute wall and door applications.
  • Meets ASTM E119 for full radiant heat protection and CPSC Cat. II (400 ft. lbs.) impact safety requirements.
  • Can be used in interior and exterior applications, including clear butt-glazed walls for maximum vision and transparency.
  • Optically clear glazing without wires or tints.
  • Can be easily incorporated in GPX® Architectural Series Fire Resistive framing, GPX® SNAPCAP or GPX® Builders Series Temperature Rise framing for a complete fire resistive assembly.
  • Standard 5 year limited warranty.

Product Specifications

Thickness

1 in. (25 mm)

Weight

12.3 lbs. / sq. ft. (60 kg/m²)

Fire Rating

60 minutes with hose stream

Impact Safety Rating

CPSC 16 CFR 1201 Cat. I and II, ANSI Z97.1

Sound Reduction

Rw=42 dB

Light Transmission

81%

R-value

1.14

U-value

0.881

Application

Doors, Walls

Listings and Standards

SuperLite® II-XLM 60 is listed and labeled by Underwriters Laboratories and Intertek, nationally recognized testing laboratories approved by OSHA.

Listings

  • Intertek: 38267; 41816
  • UL: KCMZ.R14212; KCMZ7.R14212; U550; U553

Standards

  • UL 9, UL 10B, UL 10C, UL 263
  • NFPA 80, NFPA 251, NFPA 252, NFPA 257
  • ASTM E119, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01
  • CPSC 16 CFR 1201 Cat. II
  • ANSI Z97.1
  • CAN/ULC S101, CAN/ULC S104, CAN/ULC S106

Framing Options

GPX® Architectural Series Fire Resistive

GPX® SnapCap

GPX® Builders Series Temperature Rise


See More


Specifications

MAXIMUM SIZES
Fire RatingApplicationMax. CV AreaMax. CV Width Max. CV HeightStops
60 MinutesDoors3,855 in.²
(2.49 m²)
87-5/8 in.
(2.23 m)
87-5/8 in.
(2.23 m)
5/8 in.
(16 mm)
60 MinutesWalls*3,855 in.²
(2.49 m²)
87-5/8 in.
(2.23 m)
87-5/8 in.
(2.23 m)
1 in.
(25.4 mm)
*With framing and butt-glazed.