Plasti-Fab -Insulspan® Structural Insulated Panels

DOWNLOADS

The Insulspan Structural Insulated Panel (SIP) system consists of performance rated oriented strand board (OSB) structurally laminated to a core of insulation.


Category: RTA SIP systems | insulated deck panels | insulated decking...

MasterFormat: Rough Carpentry | Structural Panels | Roofing and Siding Panels...



Plasti-Fab
#300, 2891 Sunridge Way NE
Calgary, AB T1Y 7K7
Tel: (888) 446-5377

mailbox@plastifab.com

https://www.plastifab.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Insulspan® Structural Insulated Panels

The Insulspan Structural Insulated Panel (SIP) system consists of performance rated oriented strand board (OSB) structurally laminated to a core of insulation. Insulspan SIP provides building owners with a proven method of constructing walls and roofs resulting in real energy cost savings while adding resale value to the building. Insulspan SIPs use closed-cell rigid EPS insulation cores which helps reduce air leakage and thermal bridging by providing a continuous layer of thermal insulation in both wall and roof assemblies.

The Insulspan SIP System is a versatile building system that can be used in application such as Single-Family Residential, Multi-Family/Multi-Use Residential, Commercial, Community Buildings and ADUs (Accessory Dwelling Units).

Insulspan Structural Insulated Panels with EPS Cores are available in the following thicknesses:

  • 4 ½ - R 15
  • 6 ½ - R 22.6
  • 8 ¼ - R 29.2
  • 10 ¼ - R 36.8
  • 12 ¼ - R 44.4

Insulspan R-Plus Structural Insulated Panels with NEOPOR Cores (GPS) are available in the following thicknesses:

  • 4 ½ - R 18.3
  • 6 ½ - R 27.7
  • 8 ¼ - R 35.9
  • 10 ¼ - R 45.3
  • 12 ¼ - R 54.7

Why Insulspan® Structural Insulated Panels

  • Insulspan® Structural Insulated Panel (SIP) Building System is the industry’s most complete ready-to-assemble system
  • Green building solution that creates high-performance building envelopes to meet or exceed stringent energy codes
  • Build faster with a pre-fabricated shell and reduce on-site construction waste
  • In-house team of design experts (put this bullet third from bottom when adding in new bullets)
  • Structural strength and ability to span large distances offers designers and architects increased flexibility when creating interesting and unique designs
  • Airtight building envelope creates a healthier, more comfortable interior environment for the building’s occupants
  • Advisors and installers available
  • Code Listed in US and Canada

Specs

Material Properties of Insulspan® SIP System

The Insulspan® SIP (Structural Insulated Panel) System is an energy efficient building system consisting of a PlastiSpan® insulation core with oriented strand board (OSB) structurally laminated to the interior and exterior faces. PlastiSpan insulation is an expanded polystyrene (EPS) insulation manufactured to meet ASTM C578, Type I, Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation, and CAN/ULC-S701, Type 1, Standard for Thermal Insulation, Polystyrene, Boards and Pipe Covering.

Note: The thermal resistance (R-value/RSI-value) and thermal transmittance (U-factor) values above are for an Insulspan SIP only at a mean temperature of 75 °F (24 °C) and do not include panel framing or connection material, interior/exterior cladding or finish materials and interior/exterior air films.

Insulspan SIP wall and roof assemblies require fewer framing members than conventional wood frame construction resulting in energy efficient building construction with higher overall thermal resistance (lower overall thermal transmittance). In addition, air leakage is one of the biggest sources of energy loss in most buildings. Air leakage rate and overall thermal resistance (or thermal transmittance) are measures used to determine the energy efficiency of building construction. Significantly lower air leakage rates are achievable for energy efficient buildings constructed using the Insulspan SIP System.

The combined higher overall R-value/RSI-value and lower air leakage characteristic for building assemblies built with the Insulspan SIP System results in significant long-term energy cost savings versus other construction methods such as wood frame construction.

The Insulspan® R-Plus SIP System is an energy efficient structural insulated panel (SIP) system consisting of an EnerSpan® insulation core with oriented strand board (OSB) structurally laminated to the interior and exterior faces. EnerSpan® insulation is an expanded polystyrene (EPS) insulation with a silver-grey colour manufactured using Neopor® F5300 Plus provided by BASF. Neopor F5300 Plus is a graphite-enhanced expandable polystyrene (GPS) raw material that reduces radiation heat transfer resulting in EPS insulation with a higher thermal resistance compared to standard white EPS insulation.

Note: The values for thermal resistance (R/RSI-value) and thermal transmittance (U-factor) in the table above are for the Insulspan R-Plus SIP only at a mean temperature of 75 °F (24 °C). The values do not include panel framing/connection material, exterior cladding, interior finish materials or interior and exterior air films.

Insulspan R-Plus SIP wall and roof assemblies require fewer framing members than conventional wood frame construction resulting in energy efficient building construction with higher overall thermal resistance (lower overall thermal transmittance). In addition, air leakage is one of the biggest sources of energy loss in most buildings. Air leakage rate and overall thermal resistance (or thermal transmittances) are measures used to determine the energy efficiency of building construction. Significantly lower air leakage rates are achievable for energy efficient buildings constructed using the Insulspan R-Plus SIP System.

The combined higher overall R/RSI-value and lower air leakage characteristic for building assemblies built with the Insulspan R-Plus SIP System result in significant long-term energy cost savings versus other construction methods such as wood frame construction.


See More


Specifications

Material Properties of Insulspan® SIP System
SIP Total Thickness Thickness EPS Core & OSB Thermal Resistance Thermal Transmittance SIP Weight
Inches mm Inches mm ft2•h•ºF
BTU
m2ºC
W
BTU
ft2•h•ºF
W
m2ºC
lb/ft2 kg/m2
4 1/21147/16
3 5/8
7/16
11
92
11
15.02.640.0670.3793.215.7
6 1/21657/16
5 5/8
7/16
11
143
11
22.63.980.0440.2513.416.5
8 1/42107/16
7 3/8
7/16
11
187
11
29.25.150.0340.1943.517.2
10 1/42607/16
9 3/8
7/16
11
238
11
36.86.490.0270.1543.718.1
12 1/43117/16
11 3/8
7/16
11
289
11
44.47.830.0220.1283.918.9
SIP Total Thickness Thickness EPS Core & OSB Thermal Resistance Thermal Transmittance SIP Weight
Inches mm Inches mm ft2•h•ºF
BTU
m2ºC
W
BTU
ft2•h•ºF
W
m2ºC
lb/ft2 kg/m2
4 1/21147/16
3 5/8
7/16
11
92
11
18.33.220.0550.3113.316.1
6 1/21657/16
5 5/8
7/16
11
143
11
27.74.870.0360.2053.517.1
8 1/42107/16
7 3/8
7/16
11
187
11
35.96.320.028 0.1583.718.0
10 1/42607/16
9 3/8
7/16
11
238
11
45.37.980.0220.1253.919.0
12 1/43117/16
11 3/8
7/16
11
289
11
54.79.630.0180.1044.120.0