Monoglass® Spray-On Insulation -Monoglass Spray-On Insulation

DOWNLOADS
The Solution for Hard-to-Insulate Areas

Monoglass® combines soft glass fibers and polymer adhesive to create a non-combustible, non-toxic, insulation that can be quickly spray applied to virtually any surface or configuration.


Category: 095100 | acoustic control products | fire-resistant acoustic insulation...

MasterFormat: Thermal Protection | Thermal Insulation | Sprayed Insulation...



Monoglass® Spray-On Insulation
922 - 1200 West 73rd Avenue
Vancouver, BC V6P 6G5
Tel: (888) 777-2966
Fax: (604) 261-1342

sales@monoglass.com

https://monoglass.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Monoglass Spray-On Insulation

The Solution for Hard-to-Insulate Areas

Monoglass® combines soft glass fibers and polymer adhesive to create a non-combustible, non-toxic, insulation that can be quickly spray applied to virtually any surface or configuration. With an R-value of 4.00/inch, installations of R-20 overhead, or R-28 on vertical surfaces can be applied quickly and easily in one pass without costly, slow layering or mechanical support.

Monoglass is applied by trained applicators using approved equipment, ensuring quality control and consistency.

  • Non-combustible Class 1 building material
  • 0 Flame Spread / 0 Smoke Development
  • Can be applied over fireproofing materials to add thermal/acoustic insulation
  • Inorganic fiberglass insulation won’t support mold growth
  • Minimum 58% re-cycled content add to LEED credits
  • Provides R-4.00 / inch thermal resistance
  • Can also be used as an effective acoustic insulation, providing NRC .95 with just 2 inches
  • Reduces sound transmission between spaces
  • Can be applied on horizontal surfaces up to 5″ thick without mechanical support, providing R-20
  • Can be applied on vertical surfaces up to 7″ thick without mechanical support, providing R-28
  • Quick, one pass application with no layering required.

Acoustic Treatment - Noise control within a space

Monoglass® Spray-On provides aesthetics and excellent reverberation control in:

  • Night clubs
  • Television and film studios
  • Auditoriums
  • Gymnasiums & sport facilities
  • Theaters
  • Factories and machine shops
  • Restaurants
  • Offices and retail shops

Safe For Use Over Fireproofing

Monoglass Spray-On is approved for use over fireproofing materials because it is non-combustible and will not affect the fire ratings of the fireproofing materials it is applied to. Because it is sprayed right over the fireproofing, it helps solve normally difficult design problems such as how to insulate the underside of corrugated steel decking.

Structural fireproofing and Monoglass thermal/acoustic insulation combine to achieve required fire ratings, thermal values and acoustic properties on steel or concrete structures.

APPROVALS

Monoglass has undergone numerous tests over the past 35 years and meets the following standards for Non-Combustibility:

  • ASTM E-136-82
  • CAN 4-S114-78
  • ISO 1182-90 / Part 1 of IMO FTP Code
  • SABS 0177 Part V
  • IMO Resolution A 472

Monoglass® does not support mold growth.

Unfortunately, mold has become a substantial problem in almost all areas of building construction. When a product is being chosen, the specification writer must have confidence that the product utilized will not support mold growth at any time during the life of the building. The health of the people using a building as well as liability considerations must be taken into account for the projected life span of any new project.

Monoglass helps eliminate mold concerns.

In order for mold to grow, there needs to be a food source. Organic, paper based products provide an abundant source of food. The only way for these products to reduce the risk of mold is through the addition of chemicals, which over time may lose their effectiveness.

As a fiberglass based product, Monoglass is inorganic and therefore incapable of supporting mold growth. Simply put, the mold has no food source. There is no need for the addition of any chemical products to retard mold growth. Therefore, there is never a need to reapply any chemicals in order to maintain mold resistance.

Monoglass Spray-On Acoustic treatment

Sound control between spaces

Sound control in the environment has become absolutely necessary in a complex society, be it where we work, live or play. Cotton-like Monoglass® Spray-On is non-combustible and exceeds older, inefficient, non-permanent systems without increasing construction costs. In addition to having high STC and NRC ratings, Monoglass is pneumatically applied, which helps seal cracks and holes in drywall, fills voids normally left by batt insulations, and seals around plumbing and electrical outlets to prevent sound ‘leaks’.


See More


Specifications

Monoglass Test Standards
Test StandardTestRequirementResult
Thermal ResistanceASTM C-518Report ValueRSI = 28.12 m*K/W
R = 4.00 F*ft2*hr/BTU inch
Thermal ConductanceASTM C-518Report ValueKSI = 0.036 W/(m*k)
K = 0.25 BTU*inch/(ft*hr*F)
Noise Reduction
Coefficient
ASTM C-423/ISO 354Report ValueNRC 0.55 @ 0.7”/17mm
NRC 0.75 @ 1”/25mm
NRC 0.80 @ 1.4”/35mm
NRC 0.95 @ 2”/50mm
Non-CombustibilityCAN S114, ASTM E-136Non-CombustibleNon-Combustible
Surface Burning CharacteristicsASTM E-84
CAN S102
Flame Spread < 25
Smoke Developed < 50
Flame Spread = 0
Smoke Developed = 0
Smolder ResistanceULC-C723(S)Mass Loss < 5.0%Mass Loss 0.37%
Low VOC EmissionsCDPH V1.2 - 2017<0.5 mg/m3Passed
Air ErosionASTM E-859Report ValueNo Weight Loss
Wind Tunnel Test*ASTM D3161No Detectable DamageASTM D3161
Fungal Bacterial ResistanceASTM G-21 & MIL STD810FNo Growth of FungiNo Growth of Fungi or Bacteria
*Wind Tunnel test data to a modified, non-standard application of Monoglass. Contact Monoglass Inc. for complete information.