Berridge Metal Roof and Wall Panels -Curved or Tapered High Seam Standing Seam System

DOWNLOADS

The Berridge High Seam Tee-Panel can be curved or tapered giving it strong aesthetic appeal. This panel is a popular choice for a wide range of project types featuring a curved or tapered application that would benefit from the wide 18 1/4″ coverage and high seams.


Category: conical roofing | integral standing seam roofing | snap-lock metal roofing panels...

MasterFormat: Metal Roof Panels | Flashing and Sheet Metal | Sheet Metal Roofing...



Berridge Metal Roof and Wall Panels
2610 Harry Wurzbach
San Antonio, TX 78209
Tel: (800) 669-0009
Fax: (210) 650-0379

info@berridge.com

https://www.berridge.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Curved or Tapered High Seam Standing Seam System

The Berridge High Seam Tee-Panel can be curved or tapered giving it strong aesthetic appeal. This panel is a popular choice for a wide range of project types featuring a curved or tapered application that would benefit from the wide 18 1/4″ coverage and high seams.

Materials
24 and 22 Gauge Steel
0.032 Aluminum

Specifications
Uses: Roof, Fascia**
Coverage: 18 ¼"
Finishes: Striated, optional smooth
Fasteners: Concealed
Applications: Solid sheathing
Seam: 1" or 1 ½" snap-on with extruded vinyl weatherseal

Installation
High Seam Tee Panels, straight and curved, are formed on-site using the Berridge SS-1421 Roll Former. Snap-on seams are also curved with the SS-1421 Roll Former
1” Seam: Convex at a minimum of 5’, Concave at a minimum of 8’
1 ½” Seam: Convex at a minimum of 8’, Concave is not available
Straight Tapered High Seam Tee-Panels can be formed on site with the Berridge SL-24 Roll Former and can not be curved
High Seam Tee-Panels can not be compound curved
Extruded vinyl weatherseal is an integral part of snap-on seam cap and prevents siphoning or flooding over seam
Extra snap-on seam caps are factory formed to a maximum of 40’
Use Seam Sleeve for splicing snap-on seams
Entire roof area shall be covered with Berridge approved underlayment
Use 1” or 1 1/2” Folding Tee-Clip*
Use 1” or 1 1/2” Stainless Steel Folding Tee-Clip with Aluminum panels*

Note: * Consult the Berridge Technical department or the Curved and/or Tapered High Seam Tee-Panel downloads for clip spacing ** Fascia can not be curved or tapered


See More


Specifications