Weather Barriers - Sikaflex®-11 FC
One part advanced polyurethane, elastomeric sealant/adhesive
Sikaflex®-11 FC is a one-component, gun-grade, adhesive and sealing compound of permanent elasticity. This dual-purpose material is based on a special moisture-cured polyurethane with an accelerated curing time that meets ASTM C920 Type S, Grade NS, Class 12.5, Use NT, I, M, G, A, O. and Federal Specification TT-S-00230C.
- Excellent adhesion on all cement-based materials, brick, ceramics, glass, metals, wood, epoxy, polyester and acrylic resin.
- Fast cure rate.
- Good weathering and water resistance.
- Non-corrosive.
- Can be painted over with water, oil, and rubber-based paints. (Preliminary tests recommended).
- High durability.
- Can be used in tamper resistant joints
Usage
As an elastic adhesive for:
- Cover plates, gaskets and coverings.
- Acoustic ceiling tiles.
- Floor moldings and door sills.
- Light weight construction materials.
- Wood or metal and door frames.
- Roof tiles.
As an elastic joint sealer for:
- Air ducts and high vacuum systems.
- Containers, tanks, and silos.
- Gaskets in openings in walls or floors for ducts, piling, etc.
- Reservoirs or water retaining structures.
- Aluminum fabrication.
- Bolted lap joints.
Advantages
- Excellent adhesion on all cement-based materials, brick, ceramics, glass, metals, wood, epoxy, polyester and acrylic resin.
- Fast cure rate.
- Good weathering and water resistance.
- Non-corrosive.
- Can be painted over with water, oil, and rubber-based paints. (Preliminary tests recommended).
- High durability.
- Can be used in tamper resistant joints
Packaging
10.1 fl.oz. (.300 ml) plastic cartridges, 24/case.
20 fl.oz. (600 ml) uni-pac sausages, 20/case.
Color
White
Product Details
Product Information
Shelf Life12 months in unopened container.
Storage ConditionsStore at 40-95 °F (4-35 °C).
Condition material to 65-75 °F before using.
Volatile organic compound (VOC) content28.5 g/L
Technical Information
Chemical ResistanceGood resistance to water, weak acids, weak alkalis, sewerage, mineral oils, vegetable oils, fats, fuels. (Not resistant to organic solvents, paint thinner, strong acids, strong alkalis). Consult Technical Service for specific data.
Service Temperature-40 °F to 170 °F
Resistance to WeatheringExcellent
Application
Application Information
Ambient Air Temperature40 °F to 100 °F.
Sealant should be installed when joint is at mid-range of its anticipated movement.
Application Steps
SUBSTRATE PREPARATIONClean all surfaces. Joint walls must be sound, clean, dry, frost-free, and free of oil and grease. Curing compound residues and any other foreign matter must be thoroughly removed. A roughened surface will also enhance bond.
Priming
Priming is not usually necessary for anodized aluminum, steel, non-absorbent materials such as glass, ceramics, stoneware and tiles. Most substrates only require priming if testing indicates a need or where sealant will be subjected to water immersion after cure. Consult Technical Service at 1-800-933-SIKA for additional information on priming.