Sika Corporation -Sika Sarnafil Insulation/Roof Boards - Sarnatherm® EPS Tapered

DOWNLOADS

Rigid expanded polystyrene insulation board

Sarnatherm EPS is a sloped, rigid expanded polystyrene insulation board.


Category: cover board | cover board insulation | insulation cover board...

MasterFormat: Thermal Protection | Thermal Insulation | Board Insulation...


Related Products

Overview


Sika Sarnafil Insulation/Roof Boards - Sarnatherm® EPS Tapered

Rigid expanded polystyrene insulation board

Sarnatherm EPS is a sloped, rigid expanded polystyrene insulation board. Sarnatherm EPS is installed directly on the substrate (depending on local code or FM requirements), over an approved thermal barrier, or directly on the existing roof surface prior to the application of the Sarnafil® membrane or Sikaplan® membrane.

  • Manufactured with no CFCs or HCFCs
  • Virtually no GWP (Global Warming Potential)
  • Zero ODP (Ozone Depletion Potential)
  • Recognized as resistant to mold growth

Usage

Wherever insulation is required within a conventional roof assembly. AREAS OF APPLICATION
  • New Roofs
  • Recover Roofs
  • Mechanically Attached Systems
  • Adhered Systems

Advantages

  • Manufactured with no CFCs or HCFCs
  • Virtually no GWP (Global Warming Potential)
  • Zero ODP (Ozone Depletion Potential)
  • Recognized as resistant to mold growth

Packaging

  • 4 ft x 4 ft (1.2 m x 1.2 m)
  • Various Thicknesses

Product Details

Sustainability / Certifications / Approvals

APPROVALS / STANDARDS
  • ASTM C 578 Type II (20 psi)
  • UL 1256, 790, 263
  • FM 4450, 4470
  • Miami‐Dade County
  • State of Florida

Product Information

Chemical Base

Polystyrene Foam Core

Shelf Life

N/A

Storage Conditions

When stored outdoors, the insulation should be stacked on pallets at least 4” (102 mm) above the surface level and protected from exposure to direct sunlight and weather using an opaque, light-colored tarpaulin. Do not use a dark colored tarpaulin. The factory applied packaging is intended only for protection during transit and should only be slit enough to prevent accumulation of condensation then removed prior to immediate use. Insulation that becomes wet or damaged should be removed and replaced with dry insulation.

Technical Information

Application

Application Steps

APPLICATION INSTRUCTIONS

Sarnatherm EPS is installed by a Sarnafil Authorized Applicator. Sarnatherm EPS may be installed either by mechanical‐attachment to the roof deck with Sarnafasteners and Sarnaplates, by full attachment with low rise sprayed urethane foam or partial attachment with foam adhesive (options depend on deck type and Sarnafil system to be installed). Contact Sika Corporation - Roofing Technical Department regarding alternative methods of attachment.


See More


Specifications

Compressive Strength
Type VIIIType IIType IX
13.0 psi (90 kPa)15.0 psi (104 kPa)25.0 psi (173 kPa)

Minimum values at yield or 10 % deformation, whichever occurs first.

Density
Type VIIIType IIType IX

Nominal

1.25 psf

1.5 psf2.0 psf

Minimum

1.15 psf1.35 psf1.8 psf
Dimensional Stability
Type VIIIType IIType IX
2%2%2%

Maximum values

Flexural Strength
Type VIIIType IIType IX
30 psi (208 kPa)35 psi (240 kPa)50 psi (345 kPa)

Minimum values

Permeability to Water Vapor
Type VIIIType IIType IX
3.5 perm3.5 perm2.5 perm

Maximum values, 1" thickness

Reaction to Fire

Oxygen index:

Type VIII
Type IIType IX
24.024.024.0

(ASTM D-2863)

Type VIIIType IIType IX
252525
Type VIIIType IIType IX
450450450
Service Temperature

Type VIII

Type II

Type IX

165°F (74°C)

165°F (74°C)165°F (74°C)

Thermal Conductivity
C-value per inch, BTU/hr.ft2.°F
@25°F (-4°C)@40°F (5°C)@75°F (24°C)

0.22

0.24

0.26

@25°F (-4°C)@40°F (5°C)@75°F (24°C)

0.21

0.22

0.24

@25°F (-4°C)@40°F (5°C)@75°F (24°C)

0.20

0.21

0.23

Thermal resistance
R-value per inch, hr.ft2.°F/BTU

Type VIII

@25°F (-4°C)
@40°F (5°C)@75°F (24°C)

4.5

4.3

3.9
@25°F (-4°C)@40°F (5°C)@75°F (24°C)

4.8

4.6

4.2

@25°F (-4°C)@40°F (5°C)@75°F (24°C)

5.0

4.8

4.4

Water Absorption
Type VIIIType IIType IX
332

Maximum values,% by volume