Sarnatherm® XPS tapered is a sloped, rigid extruded polystyrene insulation board that can be used in either a Sika roofing or waterproofing application.

  • Low water absorption

Category: cover board | cover board insulation | insulation cover board...

MasterFormat: Thermal Protection | Thermal Insulation | Board Insulation...


Related Products

Overview


Sika Sarnafil Insulation/Roof Boards - Sarnatherm® XPS Tapered

Rigid extruded polystyrene insulation board

Sarnatherm® XPS tapered is a sloped, rigid extruded polystyrene insulation board that can be used in either a Sika roofing or waterproofing application.

  • Low water absorption

Usage

Wherever insulation is required within a conventional roof assembly and waterproofing systems. Areas of Application
  • New Roofs
  • Recover Roofs
  • Mechanically Attached Systems
  • Adhered Systems
  • Waterproofing Systems

Advantages

  • Low water absorption

Packaging

  • Various Thicknesses
  • Sarnatherm per bundle depends on thickness

Product Details

Sustainability / Certifications / Approvals

APPROVALS / STANDARDS
  • ASTM C 578, Type XII, X, XIII, IV, VI, VII, V
  • CAN/ULC S701, Type 4

Product Information

Chemical Base

Polystyrene foam core with a smooth skin surface on the face and back surfaces

Shelf Life

N/A

Storage Conditions

When stored outdoors, the insulation should be stacked on pallets at least 4” (102 mm) above the surface level and protected from exposure to direct sunlight and weather using an opaque, light-colored tarpaulin. Do not use a dark colored tarpaulin. The factory applied packaging is intended only for protection during transit and should only be slit enough to prevent accumulation of condensation then removed prior to immediate use. Insulation that becomes wet or damaged should be removed and replaced with dry insulation

Technical Information

Application

Application Steps

APPLICATION INSTRUCTIONS

Sarnatherm® XPS tapered is installed either under or over the Sika roofing/waterproofing membrane depending on the system design. Overburden is utilized to hold the insulation in place in a waterproofing application. Polystyrene should not come in contact with PVC. Always place a separation layer such as Sarnafelt NWP between the Sarnatherm® XPS tapered and the membrane in both roofing and waterproofing applications. During installation in hot, sunny weather, protect the insulation with a white covering to prevent excessive heat build‐up and potential warping of the insulation boards.


See More


Specifications

Compressive Strength
Type VIType VIIType V
40.0 psi (276 kPa)60.0 psi (414 kPa)100 psi (690 kPa)

Minimum values at yield or 10 % deformation, whichever occurs first.

Dimensional Stability
Type VIType VIIType V
2%2%2%
Flexural Strength
Type VIType VIIType V
60.0 psi (414 kPa)75.0 psi (517 kPa)100 psi (690 kPa)

Minimum values

Permeability to Water Vapor
Type VIType VIIType V
1.5 perm1.5 perm1.5 perm

*Water vapor permeance varies with product type and thickness. Values are based on the desiccant method and they apply to insulation 1" (25 mm) or greater in thickness

Reaction to Fire
Type VIType VIIType V
Oxygen IndexOxygen IndexOxygen Index
24.024.024.0

% by volume

Type VI
Type VIIType V
Flame spreadFlame spreadFlame spread
555
Type VIType VIIType V
Smoke DevelopedSmoke DevelopedSmoke Developed
165165165
Service Temperature

Type VI

Type VII

Type V

165°F (74°C)

165°F (74°C)165°F (74°C)
Thermal resistance
Type VIType VIIType V
5.05.05.0
Thickness

Thickness

R-Value

C-Value

1.0" (25 mm)5.00.200
1.5" (38 mm)7.50.133
2.0" (51 mm)10.00.100
2.5" (64 mm)12.50.080
3.0" (76 mm)15.00.067
4.0" (102 mm)20.00.050

*Not all available thicknesses are listed.

Water Absorption
Type VIType VIIType V
0.30.30.3