Sika Corporation -Hydrophilic Swelling Waterstop - Hydrotite Adhesive

DOWNLOADS

Neoprene High Performance Contact Adhesive

Hydrotite Adhesive can be used to bond Sika® Hydrotite® swellable rubber waterstop profiles to hardened, cured concrete, steel, and many other smooth surfaces.

  • Long bonding range

Category: seals | waterstops

MasterFormat: Concrete Forming and Accessories | Concrete Accessories | Waterstops


Related Products

Overview


Hydrophilic Swelling Waterstop - Hydrotite Adhesive

Neoprene High Performance Contact Adhesive

Hydrotite Adhesive can be used to bond Sika® Hydrotite® swellable rubber waterstop profiles to hardened, cured concrete, steel, and many other smooth surfaces.

  • Long bonding range
  • Excellent initial strength
  • High heat resistance
  • Hydrotite Adhesive meets the specification requirements of MMM-A-121 and MIL-A-21366A

Usage

For use in adhering Hydrotite Adhesive to smooth and dry surfaces.

Advantages

  • Long bonding range
  • Excellent initial strength
  • High heat resistance
  • Hydrotite Adhesive meets the specification requirements of MMM-A-121 and MIL-A-21366A

Packaging

4 gal./carton; 12 qts./carton

Color

Gray/Green, Light Yellow

Base: Polychloroprene

Product Details

Product Information

Shelf Life

When stored at the recommended conditions in the original, unopened container, Hydrotite Adhesive has a shelf life of 15 months.

Storage Conditions

Store product at 60-80°F (16-27°C) for maximum storage life. Higher temperatures can reduce normal storage life. Lower temperatures can cause increased viscosity of a temporary nature. Rotate stock on a “first in-first out” basis.

Conditioning:

For best results the temperature of the adhesive and surfaces to be bonded should be at least 65°F (18°C). If stored below 30°F (-1°C), warm-up to room temperature in a warm room only (do not exceed 120°F (49°C) followed by thorough agitation).

Density

Solilds content (by wt.): 23-27%

Net weight (approx.): 6.6-7.0 lbs./gal.

Dimensions

Brookfield Viscometer: RVF #2 Sp. @ 20 rpm @ 80oF (27oF)

Thickness

200-450 cps

Application

Application Information

Curing Rate

Adhesive dries to a tacky condition in about 10 minutes. High humidity will slow drying while high temperatures will speed drying.

Consumption

Coverage

Coverage (approx.) @ 2.5 gms (dry wt.)/ft2: 308 ft2 per gallon

Application Steps

SUBSTRATE PREPARATION

Remove all dust, dirt, oil, grease, wax, loose paint, etc. When applying to surfaces other than concrete, wiping with solvent such as Methyl Ethyl Ketone (MEK) will aid in preparing the surface for bonding*.

*When using solvents, extinguish all ignition sources, including pilot lights, and follow the manufacturer’s precautions and directions for use. Strictly follow solvent manufacturer’s warnings and instructions for use.

Mixing: Stir or agitate well before using for optimum results.


See More