Mitsubishi Electric HVAC-Proposed - K-Generation R2-Series H2i® - CITY MULTI VRF - Air Source-0_PURY-HP192TSKMU-A-H

K-Generation R2-Series H2i® - CITY MULTI VRF - Air Source-0_PURY-HP192TSKMU-A-H


Category: air source energy recovery | air source energy recovery equipment | air-source energy recovery...

MasterFormat: Decentralized Unitary HVAC Equipment | Room Air-Conditioners | Air-Source Unitary Heat Pumps...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



K-Generation R2-Series H2i® - CITY MULTI VRF - Air Source - 0_PURY-HP192TSKMU-A-H

K-Generation R2-Series H2i® - CITY MULTI VRF - Air Source


Model Number: 0_PURY-HP192TSKMU-A-H



Power Source Voltage, Phase, Cycle 208 / 230V, 3-Phase, 60Hz
Cooling Capacity (Nominal) 144000 Btu/h (42.2 kW) 1
Cooling Power Input (Nominal) 10.85 kW 3
Cooling Current Input (Nominal) 33.4 / 30.2 Ampere
Heating Capacity (Nominal) 160000 Btu/h (46.9 kW) 1
Heating Power Input (Nominal) 13.16 kW 3
Heating Current Input (Nominal) 40.5 / 36.7
Minimum Circuit Ampacity MCA 44 / 40 Ampere
Maximum fuse size (time delay) 60 Ampere
Recommended Fuse/Breaker Size 50 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1 oz (11.8 kg)
Compressor Type x Quantity Inverter scroll hermetic compressor x 1
Fan Airflow Rate 6200 CFM (175 m³/min) / 6200 CFM (175 m³/min)
Sound Pressure Level (measured in anechoic room) 61 dB(A)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~36
Refrigerant Pipe Size O.D. Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Size O.D. Gas Side (R22) 1-1/8 Inched (28.58 mm) Brazed
Operating Temperature Range Cooling (Outdoor) 23 ~ 115° F (-5 ~ +46° C) **
Operating Temperature Range Heating (Outdoor) -13~60° F(-25~15.5° C)

Power Source Voltage, Phase, Cycle 208 / 230V, 3-Phase, 60Hz
Cooling Capacity (Nominal) 144000 Btu/h (42.2 kW) 1
Cooling Power Input (Nominal) 10.85 kW 3
Heating Capacity (Nominal) 160000 Btu/h (46.9 kW) 1
Heating Power Input (Nominal) 13.16 kW 3
Minimum Circuit Ampacity MCA 26 Ampere
Maximum fuse size (time delay) 30 Ampere
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1 oz (11.8 kg)
Compressor Type x Quantity Inverter scroll hermetic compressor x 1
Fan Airflow Rate 6200 CFM (175 m³/min) / 6200 CFM (175 m³/min)
Sound Pressure Level (measured in anechoic room) 61 dB(A)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~36
Refrigerant Pipe Size O.D. Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Size O.D. Gas Side (R22) 1-1/8 Inches (28.58 mm) Brazed
Operating Inlet Water Temp. Range Cooling 23 ~ 115° F (-5 ~ +46° C) **
Operating Inlet Water Temp. Range Heating -13~60° F(-25~15.5° C)

Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 192000 Btu/h (56.3 kW) 1
Cooling Power Input (Nominal) 15.86 kW 3
Heating Capacity (Nominal) 215000 Btu/h (63 kW) 1
Heating Power Input (Nominal) 18.52 kW 3
Heating Current Input (Nominal) 55.9 / 50.5 Ampere
Minimum Circuit Ampacity MCA 60 / 54 Ampere
Maximum fuse size (time delay) 80 Ampere
Recommended Fuse/Breaker Size 65 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1oz (11.8kg)
Fan Airflow Rate 6200 CFM (175 m³/min) / 6200 CFM (175 m³/min)
Sound Pressure Level (measured in anechoic room) 61 dB(A)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~36
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Refrigerant Pipe Size O.D. Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Operating Temperature Range Cooling (Outdoor) 23 ~ 115° F (-5 ~ +46° C) **
Operating Temperature Range Heating (Outdoor) -13~60° F(-25~15.5° C)

Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 192000 Btu/h (56.3 kW) 1
Cooling Power Input (Nominal) 15.86 kW 3
Heating Capacity (Nominal) 215000 Btu/h (63 kW) 1
Heating Power Input (Nominal) 18.52 kW 3
Minimum Circuit Ampacity MCA 32 Ampere
Maximum fuse size (time delay) 35 Ampere
Recommended Fuse/Breaker Size 35 Ampere
Refrigerant Type R410A x 26 lbs + 1oz (11.8kg)
Fan Airflow Rate 6200 CFM (175 m³/min) / 6200 CFM (175 m³/min)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~36
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Refrigerant Pipe Size O.D. Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Operating Temperature Range Cooling (Outdoor) 23 ~ 115° F (-5 ~ +46° C) **
Operating Temperature Range Heating (Outdoor) -13~60° F(-25~15.5° C)

Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 72000 Btu/h (21.1 kW) 1
Cooling Power Input (Nominal) 5.08 kW 3
Heating Capacity (Nominal) 80000 Btu/h (23.4 kW) 1
Heating Power Input (Nominal) 6.26 kW 3
Minimum Circuit Ampacity MCA 44 / 40 Ampere
Maximum fuse size (time delay) 60 Ampere
Recommended Fuse/Breaker Size 50 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1 oz (11.8 kg)
Compressor Type x Quantity Inverter scroll hermetic compressor x 1
Fan Airflow Rate 6200 CFM (175 m³/min)
Sound Pressure Level (measured in anechoic room) 58 dB(A)
Dimensions H x W x D Height 64-31/32 Inches (1650 mm)
Dimensions H x W x D Width 48-1/16 Inches (1220 mm)
Dimensions H x W x D Depth 29-15/16 Inches (760 mm)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06 - P96 / 1 to 18
Operating Inlet Water Temp. Range Cooling 23~109° F (-5~43° C) D.B. **
Operating Inlet Water Temp. Range Heating -13~60° F (-25~15.5° C) W.B.

Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 72000 Btu/h (21.1 kW) 1
Cooling Power Input (Nominal) 5.08 kW 3
Heating Capacity (Nominal) 80000 Btu/h (23.4 kW) 1
Heating Power Input (Nominal) 6.26 kW 3
Minimum Circuit Ampacity MCA 20 Ampere
Maximum fuse size (time delay) 30 Ampere
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1 oz (11.8 kg)
Compressor Type x Quantity Inverter scroll hermetic compressor x 1
Fan Airflow Rate 6200 CFM (175 m³/min)
Sound Pressure Level (measured in anechoic room) 58 dB(A)
Dimensions H x W x D Height 64-31/32 Inches (1650 mm)
Dimensions H x W x D Width 48-1/16 Inches (1220 mm)
Dimensions H x W x D Depth 29-15/16 Inches (760 mm)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06 - P96 / 1 to 18
Operating Temperature Range Cooling (Outdoor) 23~109° F (-5~43° C) D.B. **
Operating Temperature Range Heating (Outdoor) -13~60° F (-25~15.5° C) W.B.

Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 96000 Btu/h (28.1 kW) *1
Cooling Power Input (Nominal) 7.66 kW *3
Heating Capacity (Nominal) 108000 Btu/h (31.7 kW) *1
Heating Power Input (Nominal) 8.8 kW *3
Minimum Circuit Ampacity MCA 60 / 54 Ampere
Maximum fuse size (time delay) 65 Ampere
Recommended Fuse/Breaker Size 80 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1 oz (11.8 kg)
Fan Airflow Rate 6200 CFM (175 m³/min)
Sound Pressure Level (measured in anechoic room) 58 dB(A)
Dimensions H x W x D Height 64-31/32 Inches (1650 mm)
Dimensions H x W x D Width 48-1/16 Inches (1220 mm)
Dimensions H x W x D Depth 29-15/16 Inches (760 mm)
Indoor unit connectable Total capacity 50~150 % of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06 - P96 / 1 to 24
Operating Temperature Range Cooling (Outdoor) 23~109° F (-5~43° C) D.B. **
Operating Temperature Range Heating (Outdoor) -13~60° F (-25~15.5° C) W.B.

Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 96000 Btu/h (28.1 kW) *1
Cooling Power Input (Nominal) 7.66 kW *3
Heating Capacity (Nominal) 108000 Btu/h (31.7 kW) *1
Heating Power Input (Nominal) 8.8 kW *3
Minimum Circuit Ampacity MCA 32 Ampere
Maximum fuse size (time delay) 35 Ampere
Recommended Fuse/Breaker Size 35 Ampere
Refrigerant Type R410A
Refrigerant Charge R410A x 26 lbs + 1 oz (11.8 kg)
Sound Pressure Level (measured in anechoic room) 58 dB(A)
Dimensions H x W x D Height 64-31/32 Inches (1650 mm)
Dimensions H x W x D Width 48-1/16 Inches (1220 mm)
Dimensions H x W x D Depth 29-15/16 Inches (760 mm)
Operating Temperature Range Cooling (Outdoor) 50~150 % of outdoor unit capacity **
Operating Temperature Range Heating (Outdoor) -13~60° F (-25~15.5° C) W.B.

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com

Sweets app for Revit – Learn More