Maxxon® Corporation -Aquafin® Vaportight Coat SG3

DOWNLOADS

Product Description:

Aquafin® Vaportight Coat SG3 is a unique 2-component, moisture tolerant, high density, chemically enhanced epoxy product


Category: dampproofing | efflorescence prevention | fluid-applied vapor barriers...

MasterFormat: Concrete Finishing | Dampproofing and Waterproofing | Thermal Protection...



Maxxon® Corporation
P.O. Box 253
920 Hamel Road
Hamel, MN 55340
Tel: (800) 356-7887
Fax: (763) 478-2431

info@maxxon.com

http://www.maxxon.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Aquafin® Vaportight Coat SG3

Product Description:

Aquafin® Vaportight Coat SG3 is a unique 2-component, moisture tolerant, high density, chemically enhanced epoxy product which prevents the passage of water vapor and moisture through concrete floors and walls on or below grade. Vaportight Coat SG3 eliminates delamination of adhesives, floor coverings and coatings.

Product Advantages:

  • Water/Vapor Barrier Coating

  • Reduces moisture vapor emission

  • 1-coat application

  • Underlayment system installed next day

  • Applied to moist or dry concrete

  • High alkalinity barrier

Code Listings:

  • ESR-2540

  • ESR-1153

  • ESR-1141

  • ESR-1774

  • HUD951i

  • City of Los Angeles


See More


Specifications

Technical Data:
Vaportight Coat SG2Vaportight Coat SG3Vaportight Coat SG4
Material2-component white epoxy2-component clear epoxy2-component clear epoxy
ReductionFor slabs with MVER up to 25 lbs and RH up to 100%For slabs with MVER up to 25 lbs and RH up to 100%For slabs with MVER up to 25 lbs and RH up to 100%
Min. Requirements over New ConcreteConcrete must be a minimum of 5 days old or have reached a minimum of 2500 psi (17 MPa)Concrete must be a minimum of 5 days old or have reached a minimum of 2500 psi (17 MPa)Concrete must be a minimum of 5 days old or have reached a minimum of 2500 psi (17 MPa)
Workability Time
@ 73° F (23° C)
approx. 60 minutesapprox. 35 minutesapprox. 15 minutes
Sand Broadcast RequiredYesNo

No

Open to foot traffic
@ 73° F (23° C)
after 12 hoursafter 12 hoursafter 3.5 hours
Adhesion to Concrete
(ASTM D7234)
>480 psi>480 psi

>580 psi

VOC47 g/L0 g/L0 g/L
Recommended application thickness for 100% RH (per ASTM F 2170) and yield per kit21 mils
Yield: 160 sq. ft.
16 mils
Yield: 240 sq. ft.
16 mils
Yield: 240 sq. ft.
Option to Adjust YieldNoYesYes
Dry time before pourminimum 24 hoursminimum 12 hours
maximum 5 days

INDOOR
minimum 3.5 hours
maximum 5 days

OUTDOOR
minimum 3.5 hours
maximum 24 hours

Typical Applications
  • Indoor and Outdoor
  • New and existing Concrete slabs: on grade above grade, below grade and split slabs
  • Office Buildings
  • Medical Facilities
  • Industrial/Retail Facilities
  • Educational Facilities
  • Indoor and Outdoor
  • New and existing Concrete slabs: on grade above grade, below grade and split slabs
  • Office Buildings
  • Medical Facilities
  • Industrial/Retail Facilities
  • Educational Facilities
  • Indoor and Outdoor
  • New and existing Concrete slabs: on grade above grade, below grade and split slabs
  • Office Buildings
  • Medical Facilities
  • Industrial/Retail Facilities
  • Educational Facilities
Typical Applications
  • Oil and other chemically contaminated slabs
  • Food processing plants
  • Secondary containment slabs, etc.
  • Old cementitious underlayment (no gypsum) and ceramic tiles with missing or damaged under-slab vapor barriers
  • Supermarkets
  • Food processing plants
  • Airplane hangars
  • For capillary infiltration of oil or other chemicals from the ground or to treat oil-contaminated slabs or radon infiltration
  • Old cementitious underlayment (no gypsum) and ceramic tiles with missing or damaged under-slab vapor barriers
  • Supermarkets
  • Food processing plants
  • Airplane hangars
  • For capillary infiltration of oil or other chemicals from the ground or to treat oil-contaminated slabs or radon infiltration