GAF -EnergyGuard™ Perlite Tapered Edge Strip

DOWNLOADS
Description Uses Specification Benefits Limitations GAF 1 Campus Drive Parsippany, NJ 07054 Tollfree: (800) 766-3411 Web site: http://www.gaf.com

MasterFormat: Thermal Protection | Thermal Insulation | Board Insulation...



GAF
1 Campus Drive
Parsippany, NJ 07054
Tel: (800) 766-3411

http://www.gaf.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview



EnergyGuard Perlite Tapered Edge Strip

Description

  • Factory fabricated from EnergyGuard rigid perlite insulation board.
  • Cut on angles that slope from zero on one edge to 1/2" to 2" on the opposite edge.
  • Designed for smooth transition from lower to higher elevations.
  • Easy to fabricate for installation with most types of roof systems.
  • Available in bundles 48" (1220 mm) in length.
  • Available in different heights and widths for all types of job requirements.

Uses

  • To provide smooth transition from lower to higher elevations around roof edges, drains or wherever slope to 0" is required.
  • Properly installed, EnergyGuard Perlite roof insulation is suitable for use under built-up, modified bitumen and some single ply roofing systems.
  • Refer to the application specifications in the current Membrane Manufacturer’s Application and Specifications manual for proper installation procedures for EnergyGuard Perlite roof insulation.

Specification Benefits

  • UL, ULC Flame Spread Rating 25.
  • Strong and dimensionally stable.
  • Available in standard heights and widths.
  • Can be shipped in mixed loads with roof insulation and tapered systems.
  • Multiple shipping locations.
  • Easily identifiable bundles.
  • Edge strips have at least 25% post-consumer recycled content and comply with the Environmental Protection Agency Regulation 40 CFR Part 248, “Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials,” as a recycled product approved for use on any project using federal funds.

Limitations

  • EnergyGuard Perlite roof insulation is a non-structural, non-load bearing material.
  • EnergyGuard Perlite roof insulation should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp.
  • No more insulation should be applied than can be completely covered with finished roofing on the same day.
  • It is NOT designed for use under fully adhered single ply systems nor for direct torch application of modified bitumen.
  • If torch grade modified bitumen roofing is to be installed over EnergyGuard Perlite, a fiberglass base sheet MUST first be installed.


Edge Strip Sizes*
1/2" (13 mm)X    6" (152 mm)X    48" (1220 mm)
1/2" (13 mm)X    12" (305 mm)X    48" (1220 mm)
1" (25 mm)X    6" (152 mm)X    48" (1220 mm)
1" (25 mm)X    12" (305 mm)X    48" (1220 mm)
1" (25 mm)X    18" (457 mm)X    48" (1220 mm)
1" (25 mm)X    24" (610 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    6" (152 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    12" (305 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    18" (457 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    24" (610 mm)X    48" (1220 mm)
2" (51 mm)X    12" (305 mm)X    48" (1220 mm)
2" (51 mm)X    18" (457 mm)X    48" (1220 mm)
2" (51 mm)X    24" (610 mm)X    48" (1220 mm)
* All sizes shown are nominal and subject to nominal manufacturing tolerances.


GAF
1 Campus Drive
Parsippany, NJ 07054
Tollfree: (800) 766-3411
Web site: http://www.gaf.com