GAF - EnergyGuard™ Perlite Cant Strip Insulation Board

DOWNLOADS
Description Uses Benefits Limitations Code Compliance EnergyGuard ™ Perlite Cant Strip complies with the requirements of ASTM Standard C728 (which supersedes Federal Specifications HH-I-529). UL Flame Spread Rating 25. Cant Strips have at least 25% post-consumer recycled content and comply with...

MasterFormat: Thermal Protection | Thermal Insulation | Board Insulation...



GAF
1 Campus Drive
Parsippany, NJ 07054
Tel: (800) 766-3411

http://www.gaf.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview



EnergyGuard Perlite Cant Strip Insulation Board

Description

  • Factory fabricated from rigid EnergyGuard Perlite insulation board.
  • Cut at angles that provide a true 45° angle between horizontal and vertical surfaces.
  • UL, ULC Flame Spread Rating 25.
  • Easy to fabricate for installation with most types of roof systems.
  • Strips are available in 3", 4", 5" and 5 3/4" (76, 102, 127 and 146mm) nominal sizes.

Uses

  • To provide a smooth transition from horizontal to vertical surfaces.
  • Properly installed, EnergyGuard Perlite Cant Strip is suitable for use under built-up, modified bitumen and some single ply roofing systems.
  • Refer to the application specifications in the current membrane manufacturer’s application and specifications manual for proper installation procedures for EnergyGuard Perlite Cant Strip.

Benefits

  • Strong and dimensionally stable.
  • Available in 5 standard sizes.
  • Can be shipped in mixed loads with roof insulation and tapered systems.
  • Multiple shipping locations.
  • Easily identifiable bundles.

Limitations

  • EnergyGuard Perlite Cant Strips are a non-structural, non-load bearing material.
  • EnergyGuard Perlite Cant Strips should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp.
  • No more Cant Strip should be applied than can be completely covered with finished roofing on the same day.
  • Do NOT use under fully adhered single ply systems or with direct torch application of modified bitumen.
  • If torch grade modified bitumen roofing is to be installed over EnergyGuard Perlite Cant Strips, a fiberglass base sheet MUST first be installed.

Code Compliance
EnergyGuard Perlite Cant Strip complies with the requirements of ASTM Standard C728 (which supersedes Federal Specifications HH-I-529).
UL Flame Spread Rating 25.
Cant Strips have at least 25% post-consumer recycled content and comply with the Environmental Protection Agency Regulation 40 CFR Part 248, “Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials,” as a recycled product approved for use on any project using federal funds.


Cant Sizes*
1" (25 mm)X    4" (102 mm)X    48" (1220 mm)
1" (25 mm)X    3" (76 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    4" (102 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    5" (127 mm)X    48" (1220 mm)
1 1/2" (38 mm)X    5 3/4" (146 mm)X    48" (1220 mm)
* All sizes shown are nominal and subject to nominal manufacturing tolerances.