1835 - 90 Series Telephone Entry System
Telephone Entry & Access Control
The Model 1835 is an ideal telephone entry system suited for apartment and gated community applications as well as office buildings and industrial sites. Each 1830 Series unit allows Voice and Data connection over Cellular, Internet, or a POTS (Plain Old Telephone Service) connection. The single-line LCD display features big 1/2-inch characters for easy viewing and your personalized message scrolls across the screen from right to left when the system is not in use. Our unique ″One Touch″CALL button makes this system one of the easiest to use on the market today! The built-in electronic directory, easy-to-use Remote Account Manager programming software, card reader interface, and expandability options make this unit an ideal choice for those applications with a large number of system users and entry locations. With Tracker Expansion Boards, up to 48 wired card readers (or 24 wirelessly) can be interfaced with the 1835 to provide access control. Additionally, our elevator control module restricts which floors a guest or system users have access to, making it an ideal system for high-rise buildings. For additional security, the 1835 allows you to monitor activity AS IT HAPPENS on your computer display, and with our anti-pass back memory, you can enable a TRUE anti-pass back system in one of three different configurations; passive, active, and trap.
Cloud Account Manager
Log in to the DKS Access System from any device with internet access through your preferred browser. The Cloud Account Manager enables programming and management of Entry Systems from anywhere, you’ll never have to download and upload the database, or inadvertently overwrite another administrator’s changes. It’s designed for administrators and staff of multi-unit and multi-use buildings and is compatible with DKS models 1833, 1834, 1835, 1837 Telephone Entry and Access Control Systems, and model 1838 Multi Door Card Access System.
Accessible from any browser on any internet-connected device.
MOUNTING KITS - 90 SERIES
Flush Mount Kit - Stainless Steel 1814-20
- Use when Flush Mounting a 90 Series System.
- Use with 1834, 1835 and 1837 90 Series Telephone Entry Systems only.
10 Gauge Hood - Black 1814-185
- Provides additional vandalism protection.
- Use with 1834, 1835 and 1837 90 Series Telephone Entry Systems only.
10 Gauge Hood - Stainless Steel 1814-180
- Provides additional vandalism protection.
- Use with 1834, 1835 and 1837 90 Series Telephone Entry Systems only.
3000 Names & Phone Numbers
Program multiple names and numbers per unit. Use a mobile phone number to receive calls for entry from anywhere… and grant access.
8000 Device Codes
Multiple access control device choices - mix or match card readers, keypads, and/or RF controls. • Program multiple devices for each user. • Program multiple users for each unit.
Anti Pass-Back
Prevent multiple people from using a single Access Card as it must but used to enter through the IN point and exit the OUT point before being used at the IN point again.
Elevator Control
Our elevator control module restricts which floors a guest or system users have access to, making it an ideal system for high rise buildings
Enhanced Tamper Resistance
With dual locks and tamper alert switch. Optional hood adds even more protection.
Facility Access Codes
Ensures that duplicate codes from other properties cannot work at your location.
Hold Open
Up to 7 time zones can be created to hold open a door or gate at a controlled access point.
LED Directories
Built-in single-line 20 character LCD directory display.
Specifications
- True Full Duplex Communication.
- Stores up to 3000 telephone numbers and names (names are limited to 15 characters max).
- Stores up to 255 area codes.
- Transaction buffer stores last 8000 events.
- Stores up to 8000 device (card) codes.
- 31 security (permission) levels, 29 programmable with 4 time zones each.
- 8 hold open time zones.
- Three anti-pass back configurations: passive, active and trap.
- Elevator control (note 1) for up to 8 elevators, each serving 64 floors.
- Expandable (note 2) to control up to 48 wired entry points (or 24 wirelessly).
- 4-digit entry codes, one for each telephone number.
- 3 form ″C″ dry contact relays.
- Single-line directory display uses super-twist LCD with 1/2-inch characters.
- EEPROM memory chip.
- Two 16 VAC, 20 VA power transformers supplied.
- FCC (US): DUF6VT-12874-OT-T
- DOC (CAN): 1736 4528 A
- Compliant with UL 294. ETL listed.
Note 1: Requires Elevator Control Board(s).
Note 2: Requires Tracker Expansion Board(s).
Connection Options
The 1835 Telephone Entry & Access Control System can be connected for voice and programming by any of these methods:
- Cellular 4G-LTE service (note 1)
- VoIP (note 2)
- POTS - Plain Old Telephone Service (note 3)
Note 1: Requires DKS Cellular subscription and 1800-080 cellular adapter. 4G-LTE service provided by AT&T where available.
Note 2: Requires 1830-185 (manual setup) or 1830-186 (automatic setup) TCP/IP Adapter for internet connection. 1830-186 requires IM SERVER Client subscription. VoIP requires 1815-568 VoIP adapter and subscription, or use your own provider subscription & hardware.
Note 3: Programming and voice via the telephone line and modem and phone connection at your PC, or program via your existing internet connection - using the IM Server Modem (subscription required). DoorKing does not recommend using a POTS line for programming the telephone entry system. DoorKing can no longer guarantee modem connections as some phone company services and switches no longer support modem communications as these devices are considered to be obsolete.
Mechanical
- Large easy to use A and Z scroll buttons.
- One Touch ″CALL″ button.
- Built-in single-line LCD directory display.
- Programmable directory codes (1-4 digits).
- 10 and 11-digit dialing capability.
- Interfaces with 2 card readers - expandable to 48 with wired tracker expansion boards (or 24 wirelessly).
- Live Streaming.
- Live transactions.
- Anti-pass back.
- 8000 event transaction buffer.
- 31 Security (permission) Levels - 29 Programmable (2 fixed levels).
- Database import/export capability.
- LED Lighting illuminates keypad.
- Built-in clock/calendar.
- Holiday schedule.
- Hold open time zones.
- Entry code time zones.
- Built-in postal lock provision.
Miscellaneous
- Environmental: 10° F to 145° F (-12° C to 62° C)
- Heater Kit (P/N 2600-584) Recommended when temperatures routinely fall below 35° F (1.6° C)
- Optional high-resolution camera kits additional CCV equipment and cabling required
See More
See Less