TRACO Bevel Casement
Thermal Aluminum Windows

TRACO TR-410 Casement Outswing
Heavy Commercial C-HC65

TRACO TR-420 Casement Inswing
Heavy Commercial C-HC65

The following items are provided below:
[A] TRACO TR-410 Product Description
[B] TRACO TR-410 C-HC65 Specification
[C] TRACO TR-420 Product Description
[D] TRACO TR-420 C-HC65 Specification

For half scale details and information on other TRACO products, please contact your TRACO Architectural Consultant via phone (1-800-837-7002), fax (724-776-7014), or e-mail (archservices@traco.com).

[A] TRACO TR-410 Product Description

Bevel Casement Outswing Thermal Aluminum Window

TR-410 Outswing

Heavy Commercial C-HC65

BENEFITS

Strength
  • Frame and vent members are double tubular extrusions.
  • Corners are reinforced with gussets before crimping.
  • Hardware is fastened with screws through .125” walls.
Durability
  • Glazing leg is tubular to maintain glazing pressure for water resistance.
  • Vent-to-frame gaskets are concealed to resist weathering.
  • Hinges are white bronze for corrosion resistance.

STANDARDS

  • 1” insulating glass glazed in vents with exterior bevel.
  • White bronze exposed hinges.
  • White bronze cam handles and strikes.

OPTIONS

  • Dual glazed (split vent) - maximum 1/4” exterior and interior.
  • Triple glazed (split vent) - 3/4” exterior and maximum 1/4” interior.
  • Roto operator; butt hinge/multi-point lock. (TR-410)
  • Two finishes: one on exterior and one on interior. (TR-412)
  • Integral mullions. (specify sill/left jamb-to-CMR dimension)
  • Insect screens: interior with wickets.
  • Exterior, internal, or true muntins.
  • Internal blinds.
APPLICATION RECOMMENDATIONS
(Fixed)
TR-410 TR-480
Maximum vent size: 36” x 60”* 72” x 72”
Minimum vent size: 21” x 17” 17” x 17”
Maximum vent weight: 90 lbs. 234 lbs.
Maximum glazing depth: 1” 1-1/2”
Minimum glazing depth: 1/4” 1/4”
Matching fixed window: TR-480 - -
* 72” with butt hinges

[B] TRACO TR-410 C-HC65 Specification

*TO FINISH SPECIFICATION:1. Read then delete comments in *stars*. 2. Add or delete options in (parentheses). 3. Replace preceding standards with options in [brackets] or delete options in [brackets]. 4. Revise paragraph numbers and/or letters, as necessary.*

SECTION 08520 - ALUMINUM WINDOWS

PART 1 - GENERAL

1.01 SECTION INCLUDES

A. Material: aluminum windows as on the drawings and specified in this section.

B. Installation: labor, tools, and material needed to install aluminum windows.

C. Glass and glazing.

(1.02 PRODUCTS FURNISHED BUT NOT INSTALLED)
*Enter description, e.g., extra sash sets to be supplied and stored for the future*

(1.03 PRODUCTS INSTALLED BUT NOT FURNISHED)
*Enter description, e.g., louver supplied by others to be installed in new window*

1.04 RELATED SECTIONS - Section 07900 - Sealants

1.05 REFERENCES

A. AAMA - American Architectural Manufacturers Association

  1. AAMA/NWWDA 101/I.S.2-97 “Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors”
  2. AAMA 502-90 "Voluntary Specification for Field Testing of Windows and Sliding Glass Doors"
  3. AAMA 611-98 "Voluntary Specification for Anodized Architectural Aluminum"
  4. AAMA 800-92 "Voluntary Specifications and Test Methods for Sealants"
  5. AAMA 901-96 “Voluntary Specification for Rotary Operators in Window Applications”
  6. AAMA 904-96 “Voluntary Specification for Friction Hinges in Window Applications”
  7. AAMA 1503-98 "Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall Sections"
  8. AAMA 2603-98 “Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels”
  9. AMA 2604-98 “Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels”
  10. AAMA 2605-98 “Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels”
  11. AAMA CW-10-97 "Care and Handling of Architectural Aluminum from Shop to Site"

B. ASCA - Architectural Spray Coaters Association - ASCA 96 “Voluntary Specification for Superior Performance of Organic Coatings on Architectural Aluminum Curtainwall, Extrusions and Miscellaneous Aluminum Components”

C. ASTM - American Society for Testing and Materials

  1. ASTM E 283-91 "Standard Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors"
  2. ASTM E 330-96 "Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference"
  3. ASTM E 331-96 "Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference"
  4. ASTM E 547-96 "Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential"
  5. ASTM E 774-92 "Specification for Sealed Insulating Glass Units"

1.06 SYSTEM DESCRIPTION

A. AAMA Designation: C-HC65.

B. Windows: 3-1/4" frame depth; extruded aluminum with integral structural polyurethane thermal break; vent flush with frame; vent with exterior bevel; equal-leg standard [narrow] frame; one finish type and color [one exterior finish type and color, and one interior finish type and color] factory-applied; factory-assembled.

C. Configuration: casement outswing; single vent [single vent and fixed] [multiple vents] [multiple vents and fixed] per frame.

D. Vent glazing: exterior tape; 1" insulating glass [or single lites]; EPDM gasket; interior aluminum glazing bead; glass description in paragraph 2.04; factory-glazed.

[D. Vent dual glazing: exterior tape; maximum 1/4" exterior lite; internal EPDM gasket; (blinds;) maximum 1/4" interior lite in PVC gasket in panel removable with 1/8" hex pin key; glass description in paragraph 2.04; factory-glazed.]

(E. Fixed glazing: exterior tape; 1" insulating glass [or single lites]; EPDM gasket; interior aluminum glazing bead; glass description in paragraph 2.04; factory-glazed.)

1.07 PERFORMANCE REQUIREMENTS

A. Conformance to C-HC65 specifications in AAMA/NWWDA 101/I.S.2-97 when tests are performed on a 2'0" x 4'0" minimum frame size with the following test results:

  1. Air Infiltration: maximum .05 cfm/square foot when tested per ASTM E 283-91 at a static air pressure difference of 6.24 psf.
  2. Water Penetration: no uncontrolled water leakage when tested per ASTM E 331-96 at a static air pressure difference of 10 psf.
  3. Uniform Structural: window to be operable, and maximum .4% permanent deformation per member when tested per ASTM E 330-96 at a static air pressure difference of 97.5 psf.

B. Thermal testing per AAMA 1503-98, at the prescribed 4'0" x 6'0" test size glazed with 1” insulating glass made with 1/8” clear and 1/8” Low E lites and argon gas, with the following test results:

  1. Condensation Resistance Factor: minimum 61 frame and 65 glass CRF.
  2. Thermal Transmittance: maximum .47 BTU/HR/SQ.FT/F U value.

1.08 SUBMITTALS

A. Shop drawings: window location chart; typical window elevations; details of assemblies, hardware, and glazing details for factory-glazed units.

B. Product data: manufacturer's specifications and test reports from an AAMA-accredited laboratory.

C. Samples: each specified finish for aluminum; other samples as requested.

1.09 QUALITY ASSURANCE

A. Submit for prebid approval ten days prior to bid opening a sample window representing the bid window except for color and valid test reports from an AAMA-accredited laboratory conforming to test results in Paragraph 1.07.

B. Acceptance will be by addendum only as no verbal approvals will be allowed.

C. Submit bid on prequalified products in prebid written addendum. Bidder must identify manufacturer and model of product on which the bid is based.

D. Furnish a valid AAMA “Notice of Product Certification” indicating that the windows for the project conform to AAMA/NWWDA 101/I.S.2-97.

E. Furnish visible, permanent IGCC certification labels for the CBA rating level on dual-seal double insulating glass units.

F. Manufacturer's warranties:

  1. Windows: warrant for one year against defects in material or workmanship under normal use.
  2. Dual-seal insulating glass units: warrant seal for five years *Contact TRACO for other time frames* against visual obstruction from film formation or moisture collection between internal glass surfaces, excluding that caused by glass breakage or abuse.
  3. Paint finish: PPG…
*Enter the following for an ASCA 96/AAMA 2605 fluoropolymer paint finish*

...DURANAR organic finish conforming to ASCA 96 and AAMA 2605-98: warrant for fifteen years against chipping, peeling, cracking, chalking, or fading.

*Or enter the following for an AAMA 2604 durable acrylic paint finish*

...ACRYNAR organic finish conforming to AAMA 2604-98: warrant for ten years against chipping, peeling, cracking, chalking, or fading.

*Or enter the following for an AAMA 2603 acrylic paint finish*

...DURACRON organic finish conforming to AAMA 2603-98: warrant for five years against chipping, peeling, or cracking.

(G. Project Survey: *Contact TRACO to register before project bid date* by installer and manufacturer’s representatives; one year after date of completion; to recommend maintenance procedures.)

1.10 DELIVERY, STORAGE, AND HANDLING - Handle and protect windows and accessories in accordance with AAMA CW-10-97 until project completion.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. TRACO TR-410 Casement Outswing Thermal Aluminum Window

B. Other acceptable manufacturers who have demonstrated a successful history of manufacturing for *Enter number* years equivalent products:

  1. *Enter appropriate information as required*
  2. *Enter appropriate information as required*

2.02 MATERIALS

A. Aluminum extrusions: produced from commercial quality 6063-T5 alloy; free from defects impairing strength and durability.

B. Hardware: exposed white bronze butt hinges to rotate vent outward on vertical axis; white bronze cam handles and strikes; roto operator conforming to AAMA 901.1-90; (stainless steel limit arm with release key).

C. Weatherstrip: secured in extruded ports; double rows on vent perimeter of offset bulb gasket utilizing a Neoprene foam rod for dimensional stability, a Santoprene cover for weather resistance, and a polycarbonate base for shrinkage resistance; continuous around vent corners with butt joint bonded with silicone sealant.

(D. Blinds: 1" x .008" aluminum slats; slat color chosen from manufacturer's standards; tilt adjusted with interior tilt control knob.)

(E. Screens: full; field-mounted on interior with swivel clips; handle-access wickets; 3/4" x 1 1/8" x .050" extruded tubular aluminum frame with finish to match window in color and performance; corners mitered, gusset reinforced, and crimped; 18 x 16 dark fiberglass [aluminum] mesh; PVC spline.)

2.03 FABRICATION

A. Frame: tubular members; corners mitered, gusset reinforced, and crimped.

B. Vent: tubular members; corners mitered, gusset reinforced, and crimped.

C. Frame and vent joints: factory-sealed with sealant conforming to AAMA 800-92.

D. Water control: compression gasket on vent interior to utilize pressure equalization and to allow water to drain by gravity.

2.04 DOUBLE INSULATING GLASS UNITS

A. Construction

  • Dual perimeter sealants: polyisobutylene and silicone.
  • Air space: continuous aluminum; no corner keys; desiccant (; argon-filled).

B. Exterior glass lite

  1. Thickness: 1/8" [3/16"] [1/4"].
  2. Tint: clear [bronze] [gray].
  3. Type: annealed [tempered] [laminated *Enter interlayer and lite descriptions*] [heat-strengthened].
  4. (Coating: solar-reflective.)

C. Interior glass lite

  1. Thickness: 1/8" [3/16"] [1/4"].
  2. Tint: clear [pattern #62 obscure].
  3. Type: annealed [tempered] [laminated *Enter interlayer and lite descriptions*] [heat-strengthened].
  4. (Coating: pyrolitic Low E on #3 surface.)

D. Performance

  1. Seal durability: conformance to ASTM E 774-92; visible, permanent IGCC certification label for CBA rating level.
  2. (Other: *Enter U value, etc., information as required*)

[2.04 TRIPLE INSULATING GLASS UNITS]

A. Construction

  1. Dual perimeter sealants: polyisobutylene and polyurethane.
  2. Air spaces: two continuous galvanized steel spacers; no corner keys; desiccant.

B. Exterior glass lite

  1. Thickness: 1/8" [3/16"].
  2. Tint: clear [bronze] [gray].
  3. Type: annealed [tempered] [heat-strengthened].

C. Internal film: Southwall Heat Mirror #SC75.

D. Interior glass lite

  1. Thickness: 1/8" [3/16"].
  2. Tint: clear [pattern #62 obscure].
  3. Type: annealed [tempered] [heat-strengthened].

(E. Performance: *Enter U value, etc., information as required*)

[2.04 MONOLITHIC VISION LITES]

A. Thickness: 1/8" [3/16"] [1/4"].

B. Tint: clear [bronze] [gray] [pattern #62 obscure].

C. Type: annealed [tempered] [laminated *Enter interlayer and lite description*] [heat-strengthened] [1/4 " clear wired *Enter pattern*] [polycarbonate *Enter description*].

(D. Coating: solar-reflective [pyrolitic Low E on #2 surface].)

(E. Performance: *Enter transmittance information as required*)

2.05 FINISH ON ALUMINUM EXTRUSIONS

*Enter Para. 2.05 twice if “different finishes on exterior and interior” option is desired*

A. Application: on clean extrusions free from serious surface blemishes; on exposed surfaces visible when installed product's operating sash are closed.

*Enter the following for an ASCA 96/AAMA 2605 fluoropolymer paint finish*

B. Coating: PPG DURANAR with resin containing 70% fluoropolymer; thermosetting; alternative finishes will not be acceptable.

C. Quality standard: conforming to ASCA 96 and AAMA 2605-98, including 10 years Florida exposure and 4000 hours humidity tests.

D. Pretreatment: five-stage; zinc chromate conversion coating.

E. Application: electrostatic spray and oven bake by approved applicator.

F. Coating quantity: minimum one primer coat and one color coat.

G. Dry film thickness: minimum 1.2 mils on exposed surfaces, except inside corners and channels.

H. Color: chosen from manufacturer's standards.

*Or enter the following for an AAMA 2604 durable acrylic paint finish*

B. Coating: PPG ACRYNAR with durable acrylic resin; thermosetting; alternative finishes will not be acceptable.

C. Quality standard: conforming to AAMA 2604-98, including 5 years Florida exposure and 3000 hours humidity tests.

D. Pretreatment: five-stage; zinc chromate conversion coating.

E. Application: electrostatic spray and oven bake by approved applicator.

F. Coating quantity: minimum one primer coat and one color coat.

G. Dry film thickness: minimum 1.4 mils on exposed surfaces, except inside corners and channels.

H. Color: chosen from manufacturer's standards.

*Or enter the following for an AAMA 2603 acrylic paint finish*

B. Coating: PPG DURACRON with acrylic resin; thermosetting.

C. Quality standard: conforming to AAMA 2603-98, including 1 year Florida exposure and 1500 hours humidity tests.

D. Pretreatment: five-stage; zinc chromate conversion coating.

E. Application: electrostatic spray and oven bake by approved applicator.

F. Coating quantity: one color coat.

G. Dry film thickness: minimum .8 mils on exposed surfaces, except inside corners and channels.

H. Color: chosen from manufacturer's standards.

*Or enter the following for an AAMA 611 clear anodize finish*

B. Coating: clear anodize.

C. Quality standard: conforming to AAMA 611-98.

D. Thickness: AAM10C22A41 Class I - .7 mils #215 [AAM10C22A31 Class II - .4 mils #204].

*Or enter the following for an AAMA 611 color anodize finish*

B. Coating: color anodize.

C. Quality standard: conforming to AAMA 611-98.

D. Thickness: AAM10C22A44 Class I - .7 mils.

E. Color: #313 dark bronze [#311 light bronze] [#312 medium bronze] [#315 black].

(2.06 INSTALLATION ACCESSORIES)

*Enter the following only when the standard TR-410 frame is used**

B. Material: extruded aluminum; nominal .062” wall; with exposed surfaces finished to match window color and finish performance; concealed fasteners; required weatherseals; designed for unrestricted expansion and contraction.

C. Exterior: (two-piece mullion cover;) (two-piece head and jamb receptor with thermal break;) (subsill with thermal break and end dams;) (sill cover;) (slip-on expanders).

D. Interior: (two-piece snap trim;) (stool cover).

E. Mullions: with thermal break; (stack;) (offset stack;) (three-piece).

PART 3 - EXECUTION

3.01 PREPARATION - Prepare openings to be in tolerance, plumb, level, provide for secure anchoring, and in accordance with approved shop drawings.

3.02 INSTALLATION

A. Install windows in accordance with manufacturer's recommendations and approved shop drawings with skilled craftspeople who have demonstrated a successful history of installing windows for *Enter number* years.

B. Provide required support and securely fasten and set windows plumb, square, and level without twist or bow.

C. Apply sealant per sealant manufacturer's recommendations at joints, wipe off excess, and leave exposed sealant surfaces clean and smooth.

(3.03 FIELD TESTING)

A. Test installed units in conformance with AAMA 502-90 for air and water infiltration with the window manufacturer, contractor, and owner present.

B. Select test units as directed by the owner's representative and use an AAMA-accredited laboratory provided by the owner or contractor.

3.04 ADJUSTING AND CLEANING - Adjust windows as necessary for smooth and weathertight operation, and leave windows clean and free of construction debris.

END OF SECTION

[C] TRACO TR-420 Product Description

Bevel Casement Inswing Thermal Aluminum Window

TR-420 Inswing

Heavy Commercial C-HC65

BENEFITS

Strength
  • Frame and vent members are double tubular extrusions.
  • Corners are reinforced with gussets before crimping.
  • Hardware is fastened with screws through .125” walls.
Durability
  • Glazing leg is tubular to maintain glazing pressure for water resistance.
  • Vent-to-frame gaskets are concealed to resist weathering.
  • Hinges are white bronze for corrosion resistance.

STANDARDS

  • 1” insulating glass glazed in vents with exterior bevel.
  • White bronze exposed hinges.
  • White bronze cam handles and strikes.

OPTIONS

  • Dual glazed (split vent) - maximum 1/4” exterior and interior.
  • Triple glazed (split vent) - 3/4” exterior and maximum 1/4” interior.
  • Roto operator; butt hinge/multi-point lock. (TR-410)
  • Two finishes: one on exterior and one on interior. (TR-422)
  • Integral mullions. (specify sill/left jamb-to-CMR dimension)
  • Insect screens: exterior.
  • Exterior, internal, or true muntins.
  • Internal blinds.
APPLICATION RECOMMENDATIONS
(Fixed)
TR-420 TR-480
Maximum vent size: 36” x 60”* 72” x 72”
Minimum vent size: 21” x 17” 17” x 17”
Maximum vent weight: 90 lbs. 234 lbs.
Maximum glazing depth: 1” 1-1/2”
Minimum glazing depth: 1/4” 1/4”
Matching fixed window: TR-480 - -
* 72” with butt hinges

[D] TRACO TR-420 C-HC65 Specification

*TO FINISH SPECIFICATION:1. Read then delete comments in *stars*. 2. Add or delete options in (parentheses). 3. Replace preceding standards with options in [brackets] or delete options in [brackets]. 4. Revise paragraph numbers and/or letters, as necessary.*

SECTION 08520 - ALUMINUM WINDOWS

PART 1 - GENERAL

1.01 SECTION INCLUDES

A. Material: aluminum windows as on the drawings and specified in this section.

B. Installation: labor, tools, and material needed to install aluminum windows.

C. Glass and glazing.

(1.02 PRODUCTS FURNISHED BUT NOT INSTALLED)
*Enter description, e.g., extra sash sets to be supplied and stored for the future*

(1.03 PRODUCTS INSTALLED BUT NOT FURNISHED)
*Enter description, e.g., louver supplied by others to be installed in new window*

1.04 RELATED SECTIONS - Section 07900 - Sealants

1.05 REFERENCES

A. AAMA - American Architectural Manufacturers Association

  1. AAMA/NWWDA 101/I.S.2-97 “Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors”
  2. AAMA 502-90 "Voluntary Specification for Field Testing of Windows and Sliding Glass Doors"
  3. AAMA 611-98 "Voluntary Specification for Anodized Architectural Aluminum"
  4. AAMA 800-92 "Voluntary Specifications and Test Methods for Sealants"
  5. AAMA 904-96 “Voluntary Specification for Friction Hinges in Window Applications”
  6. AAMA 1503-98 "Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall Sections"
  7. AAMA 2603-98 “Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels”
  8. AAMA 2604-98 “Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels”
  9. AAMA 2605-98 “Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels”
  10. AAMA CW-10-97 "Care and Handling of Architectural Aluminum from Shop to Site"

B. ASCA - Architectural Spray Coaters Association - ASCA 96 “Voluntary Specification for Superior Performance of Organic Coatings on Architectural Aluminum Curtainwall, Extrusions and Miscellaneous Aluminum Components”

C. ASTM - American Society for Testing and Materials

  1. ASTM E 283-91 "Standard Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors"
  2. ASTM E 330-96 "Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference"
  3. ASTM E 331-96 "Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference"
  4. ASTM E 547-96 "Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential"
  5. ASTM E 774-92 "Specification for Sealed Insulating Glass Units"

1.06 SYSTEM DESCRIPTION

A .AAMA Designation: C-HC65.

B. Windows: 3-1/4" frame depth; extruded aluminum with integral structural polyurethane thermal break; vent flush with frame; vent with exterior bevel; equal-leg standard [narrow] frame; one finish type and color [one exterior finish type and color, and one interior finish type and color] factory-applied; factory-assembled.

C. Configuration: casement inswing; single vent [single vent & fixed] [multiple vents] [multiple vents & fixed] per frame.

D. Vent glazing: exterior tape; 1" insulating glass [or single lites]; EPDM gasket; interior aluminum glazing bead; glass description in paragraph 2.04; factory-glazed.

[D. Vent dual glazing: exterior tape; maximum 1/4" exterior lite; internal EPDM gasket; (blinds;) maximum 1/4" interior lite in PVC gasket in panel removable with 1/8" hex pin key; glass description in paragraph 2.04; factory-glazed.]

(E. Fixed glazing: exterior tape; 1" insulating glass [or single lites]; EPDM gasket; interior aluminum glazing bead; glass description in paragraph 2.04; factory-glazed.)

1.07 PERFORMANCE REQUIREMENTS

A. Conformance to C-HC65 specifications in AAMA/NWWDA 101/I.S.2-97 when tests are performed on a 2’0” x 4'0" minimum frame size with the following test results:

  1. Air Infiltration: maximum .17 cfm/square foot when tested per ASTM E 283-91 at a static air pressure difference of 6.24 psf.
  2. Water Penetration: no uncontrolled water leakage when tested per ASTM E 331-96 at a static air pressure difference of 12 psf.
  3. Uniform Structural: window to be operable, and maximum .4% permanent deformation per member when tested per ASTM E 330-96 at a static air pressure difference of 97.5 psf.

B. Thermal testing per AAMA 1503-98, at the prescribed 4'0" x 6'0" test size glazed with 1” insulating glass made with 1/8” clear and 1/8” Low E lites and argon gas, with the following test results:

  1. Condensation Resistance Factor: minimum 61 frame and 65 glass CRF.
  2. Thermal Transmittance: maximum .47 BTU/HR/SQ.FT/F U value.

1.08 SUBMITTALS

A. Shop drawings: window location chart; typical window elevations; details of assemblies, hardware, and glazing details for factory-glazed units.

B. Product data: manufacturer's specifications and test reports from an AAMA-accredited laboratory.

C. Samples: each specified finish for aluminum; other samples as requested.

1.09 QUALITY ASSURANCE

A. Submit for prebid approval ten days prior to bid opening a sample window representing the bid window except for color and valid test reports from an AAMA-accredited laboratory conforming to test results in Paragraph 1.07.

B. Acceptance will be by addendum only as no verbal approvals will be allowed.

C. Submit bid on prequalified products in prebid written addendum. Bidder must identify manufacturer and model of product on which the bid is based.

D. Furnish a valid AAMA “Notice of Product Certification” indicating that the windows for the project conform to AAMA/NWWDA 101/I.S.2-97.

E. Furnish visible, permanent IGCC certification labels for the CBA rating level on dual-seal double insulating glass units.

F. Manufacturer's warranties:

  1. Windows: warrant for one year against defects in material or workmanship under normal use.
  2. Dual-seal insulating glass units: warrant seal for five years *Contact TRACO for other time frames* against visual obstruction from film formation or moisture collection between internal glass surfaces, excluding that caused by glass breakage or abuse.
  3. Paint finish: PPG…

*Enter the following for an ASCA 96/AAMA 2605 fluoropolymer paint finish*

...DURANAR organic finish conforming to ASCA 96 and AAMA 2605-98: warrant for fifteen years against chipping, peeling, cracking, chalking, or fading.

*Or enter the following for an AAMA 2604 durable acrylic paint finish*

...ACRYNAR organic finish conforming to AAMA 2604-98: warrant for ten years against chipping, peeling, cracking, chalking, or fading.

*Or enter the following for an AAMA 2603 acrylic paint finish*

...DURACRON organic finish conforming to AAMA 2603-98: warrant for five years against chipping, peeling, or cracking.

(G. Project Survey: *Contact TRACO to register before project bid date* by installer and manufacturer’s representatives; one year after date of completion; to recommend maintenance procedures.)

1.10 DELIVERY, STORAGE, AND HANDLING - Handle and protect windows and accessories in accordance with AAMA CW-10-97 until project completion.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. TRACO TR-420 Casement Inswing Thermal Aluminum Window

B. Other acceptable manufacturers who have demonstrated a successful history of manufacturing for *Enter number* years equivalent products:

  1. *Enter appropriate information as required*
  2. *Enter appropriate information as required*

2.02 MATERIALS

A. Aluminum extrusions: produced from commercial quality 6063-T5 alloy; free from defects impairing strength and durability.

B. Hardware: exposed white bronze butt hinges to rotate vent inward on vertical axis; white bronze cam handles and strikes (; stainless steel limit arm with release key).

C. Weatherstrip: secured in extruded ports; double rows on vent perimeter of offset bulb gasket utilizing a Neoprene foam rod for dimensional stability, a Santoprene cover for weather resistance, and a polycarbonate base for shrinkage resistance; continuous around vent corners with butt joint bonded with silicone sealant.

(D. Blinds: 1" x .008" aluminum slats; slat color chosen from manufacturer's standards; interior tilt control knob.)

(E. Screens: full; field-mounted exterior tracks; two stainless steel leaf springs; 5/16" x 1 1/2" x .050" extruded tubular aluminum frame with finish to match window in color and performance; corners mitered, gusset reinforced, and crimped; 18 x 16 dark fiberglass [aluminum] mesh; PVC spline.)

2.03 FABRICATION

A. Frame: tubular members; corners mitered, gusset reinforced, and crimped.

B. Vent: tubular members; corners mitered, gusset reinforced, and crimped.

C. Frame and vent joints: factory-sealed with sealant conforming to AAMA 800-92.

D. Water control: pressure equalization gasket on vent interior; tubular sill with weeps, foam baffles, and flap covers to allow water to drain by gravity and resist wind-driven water.

2.04 DOUBLE INSULATING GLASS UNITS

A. Construction

  1. Dual perimeter sealants: polyisobutylene and silicone.
  2. Air space: continuous aluminum; no corner keys; desiccant (; argon-filled).

B. Exterior glass lite

  1. Thickness: 1/8" [3/16"] [1/4"].
  2. Tint: clear [bronze] [gray].
  3. Type: annealed [tempered] [laminated *Enter interlayer and lite descriptions*] [heat-strengthened].
  4. (Coating: solar-reflective.)

C. Interior glass lite

  1. Thickness: 1/8" [3/16"] [1/4"].
  2. Tint: clear [pattern #62 obscure].Type: annealed [tempered] [laminated *Enter interlayer and lite descriptions*]
  3. [heat-strengthened].
  4. (Coating: pyrolitic Low E on #3 surface.)

D. Performance

  1. Seal durability: conformance to ASTM E 774-92; visible, permanent IGCC certification label for CBA rating level.
  2. (Other: *Enter U value, etc., information as required*)

[2.04 TRIPLE INSULATING GLASS UNITS]

A. Construction

  1. Dual perimeter sealants: polyisobutylene and polyurethane.
  2. Air spaces: two continuous galvanized steel spacers; no corner keys; desiccant.

B. Exterior glass lite

  1. Thickness: 1/8" [3/16"].
  2. Tint: clear [bronze] [gray].
  3. Type: annealed [tempered] [heat-strengthened].

C. Internal film: Southwall Heat Mirror #SC75.

D. Interior glass lite

  1. Thickness: 1/8" [3/16"].
  2. Tint: clear [pattern #62 obscure].
  3. Type: annealed [tempered] [heat-strengthened].

(E. Performance: *Enter U value, etc., information as required*)

[2.04 MONOLITHIC VISION LITES]

A. Thickness: 1/8" [3/16"] [1/4"].

B. Tint: clear [bronze] [gray] [pattern #62 obscure].

C. Type: annealed [tempered] [laminated *Enter interlayer and lite description*] [heat-strengthened] [1/4 " clear wired *Enter pattern*] [polycarbonate *Enter description*].

(D. Coating: solar-reflective [pyrolitic Low E on #2 surface].)

(E. Performance: *Enter transmittance information as required*)

2.05 FINISH ON ALUMINUM EXTRUSIONS

*Enter Para. 2.05 twice if “different finishes on exterior and interior” option is desired*

A. Application: on clean extrusions free from serious surface blemishes; on exposed surfaces visible when installed product's operating sash are closed.

*Enter the following for an ASCA 96/AAMA 2605 fluoropolymer paint finish*

B. Coating: PPG DURANAR with resin containing 70% fluoropolymer; thermosetting; alternative finishes will not be acceptable.

C. Quality standard: conforming to ASCA 96 and AAMA 2605-98, including 10 years Florida exposure and 4000 hours humidity tests.

D. Pretreatment: five-stage; zinc chromate conversion coating.

E. Application: electrostatic spray and oven bake by approved applicator.

F. Coating quantity: minimum one primer coat and one color coat.

G. Dry film thickness: minimum 1.2 mils on exposed surfaces, except inside corners and channels.

H. Color: chosen from manufacturer's standards.

*Or enter the following for an AAMA 2604 durable acrylic paint finish*

B. Coating: PPG ACRYNAR with durable acrylic resin; thermosetting; alternative finishes will not be acceptable.

C. Quality standard: conforming to AAMA 2604-98, including 5 years Florida exposure and 3000 hours humidity tests.

D. Pretreatment: five-stage; zinc chromate conversion coating.

E. Application: electrostatic spray and oven bake by approved applicator.

F. Coating quantity: minimum one primer coat and one color coat.

G. Dry film thickness: minimum 1.4 mils on exposed surfaces, except inside corners and channels.

H. Color: chosen from manufacturer's standards.

*Or enter the following for an AAMA 2603 acrylic paint finish*

B. Coating: PPG DURACRON with acrylic resin; thermosetting.

C. Quality standard: conforming to AAMA 2603-98, including 1 year Florida exposure and 1500 hours humidity tests.

D. Pretreatment: five-stage; zinc chromate conversion coating.

E. Application: electrostatic spray and oven bake by approved applicator.

F. Coating quantity: one color coat.

G. Dry film thickness: minimum .8 mils on exposed surfaces, except inside corners and channels.

H. Color: chosen from manufacturer's standards.

*Or enter the following for an AAMA 611 clear anodize finish*

B. Coating: clear anodize.

C. Quality standard: conforming to AAMA 611-98.

D. Thickness: AAM10C22A41 Class I - .7 mils #215 [AAM10C22A31 Class II - .4 mils #204].

*Or enter the following for an AAMA 611 color anodize finish*

B. Coating: color anodize.

C. Quality standard: conforming to AAMA 611-98.

D. Thickness: AAM10C22A44 Class I - .7 mils.

E. Color: #313 dark bronze [#311 light bronze] [#312 medium bronze] [#315 black].

(2.06 INSTALLATION ACCESSORIES)

*Enter the following only when the standard TR-420 frame is used*

A. Material: extruded aluminum; nominal .062” wall; with exposed surfaces finished to match window color and finish performance; concealed fasteners; required weatherseals; designed for unrestricted expansion and contraction.

B. Exterior: (two-piece mullion cover;) (two-piece head and jamb receptor with thermal break;) (subsill with thermal break and end dams;) (sill cover;) (slip-on expanders).

C. Interior: (two-piece snap trim;) (stool cover).

D. Mullions: with thermal break; (stack;) (offset stack;) (three-piece).

PART 3 - EXECUTION

3.01 PREPARATION - Prepare openings to be in tolerance, plumb, level, provide for secure anchoring, and in accordance with approved shop drawings.

3.02 INSTALLATION

A. Install windows in accordance with manufacturer's recommendations and approved shop drawings with skilled craftspeople who have demonstrated a successful history of installing windows for *Enter number* years.

B. Provide required support and securely fasten and set windows plumb, square, and level without twist or bow.

C. Apply sealant per sealant manufacturer's recommendations at joints, wipe off excess, and leave exposed sealant surfaces clean and smooth.

(3.03 FIELD TESTING)

A. Test installed units in conformance with AAMA 502-90 for air and water infiltration with the window manufacturer, contractor, and owner present.

B. Select test units as directed by the owner's representative and use an AAMA-accredited laboratory provided by the owner or contractor.

3.04 ADJUSTING AND CLEANING - Adjust windows as necessary for smooth and weathertight operation, and leave windows clean and free of construction debris.

END OF SECTION