Photoluminescent Signage – Floor Identification Signs Floor Identification Signs Every floor landing in exit enclosures that connect more than three stories must have signage designating:
ICC-7812-004 A sign shall be provided at each floor landing in exit enclosures connecting more than three stories designating the floor level, the terminus of the top and bottom of the exit enclosure and the identification of the stair or ramp. The signage shall also state the story of, and the direction to, the exit discharge and the availability of roof access from the enclosure for the fire department. The sign shall be located 5 feet (1524 mm) above the floor landing in a position that is readily visible when the doors are in the open and closed positions. Floor level identification signs in tactile characters complying with ICC A117.1 shall be located at each floor level landing adjacent to the door leading from the enclosure into the corridor to identify the floor level. 1022.8.1 Signage Requirements: Stairway identification signs shall comply with all of the following requirements:
1024.5 Illumination: Exit enclosures where photoluminescent exit path markings are installed shall be provided with the minimum means of egress illumination required by Section 1006 for at least 60 minutes prior to periods when the building is occupied. Jessup Manufacturing Company P.O. Box 366/2815 W. Route 120 McHenry, IL 60051 Tel: 800-563-1681 Fax: 815-385-0079 E-mail: sales@jessupmfg.com Web site: www.globritesystem.com |