ThermoCon
12315 Robin Blvd.
Houston, TX 77045
Phone: (713) 433-6701
Fax: (713) 433-2029
E-mail: icc@spray-on.com
Web site: http://www.spray-on.com
Industrial/Commercial Insulation for Thermal & Acoustic
Control
ThermoCon gives you temperature, sound and condensation control in one
application!
ThermoCon is a two component insulation consisting of a dry treated
fire-resistive cellulose fiber combined with a special adhesive. It is
designed to be spray applied to most any surface that can be painted with
latex paint, including wood, metal, concrete, brick, glass and
polyurethane foam. ThermoCon Industrial/Commercial insulation products are
made from specially prepared long-fibered cellulose pulps, not to be
confused with short-fibered cellulose or newspaper pulps. ThermoCon
insulation is a proven, superior product that can be used wherever
temperature, sound or condensation control is needed on interior ceilings
or walls.
ThermoCon creates a pleasing and highly productive work environment. Aesthetically
appealing, ThermoCon follows the contour of the architects design. The
product is available in five colors: White, Beige, Light Grey, Tan, Black and
"TEX-CEIL" available in White. Custom colors also available.
ThermoCon has been tested by accredited laboratories and found to be
suitable as a thermal barrier over polyurethane foam and plastic
insulation materials.
ThermoCon has been tested under the following ASTM Standard Tests and other
laboratory tests listed in this electronic program.
ASTM E 605
Thickness and Density of Sprayed Fire-Resistive Materials
ASTM E 736
Cohesion/Adhesion of Sprayed Fire-Resistive Materials
ASTM E 759
Effect of Deflection of Sprayed Fire-Resistive Materials
ASTM E 90
Laboratory Measurements of Airborne Sound Transmission Loss of Building
Partitions
ASTM C 1149-90
Self-Supported Spray Applied Cellulose Thermal/Acoustic Insulation, Type
I
ASTM C 739
Cellulose Fiber Loose Fill Thermal Insulation
ASTM E 119
Fire Test of Building Construction and Materials
ASTM E 423
Sound Absorption Coefficients
ASTM E 413
Classification for Rating Sound Insulation
ASTM C 523
Light Reflectance of Acoustical Materials
ASTM E 1042
Classification for Acoustically Absorbent Materials
ASTM C 518
Thermal Transmission Properties
ASTM E 84
Surface Burning Characteristics of Building Materials
ASTM E 859
Air Erosion of Sprayed Fire-Resistive Materials
Temperature Control
Because of its monolithic seal and the superior thermal quality created
by hollow, interlaced fibers, ThermoCon provides an outstanding barrier to
heat and cold transfer. It can be successfully applied across the entire
temperature spectrum for comfort in both hot and cold climates or to rooms
requiring rigid environmental control. ThermoCon can reduce heating and
cooling bills.
Properties: R-Value of 3.7 per inch, K-Factor of 0.27 per inch. The FTC
requires that R-Value claims be based on ASTM test methods and laboratory
tests no older than 1985. Any similar materials claiming an R-Value in
excess of 4.0 per inch cannot back this claim with valid repeatable
current testing.
Sound Control
ThermoCon, correctly applied, will absorb up to 75% of the sound caused
by the reverberations from hard surfaces such as walls, ceilings and
floors. Tests reveal these superior sound absorption qualities over a
broad range of frequencies. Manufacturing efficiencies and productivity
rates increase as sound pollution is controlled.
Flame/Smoke Test
ThermoCon Industrial/Commercial Insulation is Underwriters Laboratories,
Inc. classified and is subject to follow-up inspection. Each package of
product carries the Underwriters Classification marking as shown in the
Building Materials Directory.
TEX-CEIL
When you require a tough, fine textured seamless interior finish.
Choose ThermoCons TEX-CEIL when you require a tough, fine textured
seamless finish for interior applications in new and existing buildings
such as: schools, churches, hotels, offices, shopping malls and more.
TEX-CEILs white, fire-resistive cellulose fiber, along with the
adhesive binder, gives you a most attractive noise reduction installation.
TEX-CEIL provides the owner, architect, or designer with a unique
spray-applied finish that will provide beauty and durability, while hiding
many minor surface imperfections present in new construction and
renovation projects. It is an effective and economical alternative to such
materials as acoustical plaster, suspended ceilings, tile, paint, and
other unidimensional products. It is the ideal material for ceilings and
walls where asbestos containing materials have been removed. The product
is unaffected by normal temperature and humidity levels, will withstand
minor abuse, and is a Class 1 building material.
If a tougher, more durable surface is required, Thermo-Tuff Protective Overspray
Coating can be applied to the surface for more resilience.
Features
- Aesthetically pleasing seamless texture spray finish
- Applicable to virtually any substrate
- Provides superior acoustical values
- Durable surface
- Pleasing, consistent, fine texture surface
- High level light reflectivity
- Provides improved envelope thermal performance
- Provides thermal and acoustical improvement in one fast, easy seamless
economical installation
- Suitable for new and existing projects
Acoustical Rating: .70 NRC at 5/8 inches
on solid backing.
Light Reflectivity: Average 85%
Fire Rating: Flame Spread 5, Smoke Developed
0
Approvals and Specifications:
UNDERWRITERS LABORATORIES
Ref #9408
Flame Spread 5
Smoke Developed 0
Applied at a maximum thickness of 5". Must
be applied with ThermoBond adhesive
FEDERAL SPEC. SS-S-111C
HUD/FHA USE MATERIALS BULLETIN #80
MEETS CALIFORNIA BUREAU OF HOME FURNISHING STANDARDS
CA-T-282 (LA)
TOXICITY TEST:
UNIVERSITY OF PITTSBURGH TEST "No more toxic than wood"
Complete Testing
ThermoCon has been tested by independent laboratories in accordance with ASTM
C 1149-90 Self Supported Spray Applied Cellulosic Thermal-Acoustical Insulation,
Type I. The following was determined:
Physical Properties
Density/2.7 lb. cu. ft.
Thermal Conductivity K-Value 0.27 = R-Value
3.7
Surface Burning Characteristics
Flame Spread 5, Smoke Developed 0
Adhesive/Cohesive Strength 37 times
the weight
Smoldering Combustion Less than
1% weight loss
Fungi Resistance No fungi growth
Corrosion No corrosion on copper,
aluminum or steel
Moisture Vapor Absorption 1.43%
Odor No offensive odor
Substrate Deflection No cracking or delamination
occurred
Air Erosion Pass (0.14 g/sq.ft. pick up)
BASED ON THE ABOVE PHYSICAL PROPERTIES, THERMOCON IS IN COMPLIANCE WITH THE
REQUIREMENTS OF THE INSULATION SECTION OF CABO Model Energy Code, BOCA, ICBO
AND SBCCI BUILDING CODES.
PRODUCT WARNINGS/LIMITATIONS
ThermoCon insulation products should not be used in areas where there is prolonged
exposure to water or heat in excess of 150°F (85°C). Nor should it
be applied in areas requiring a washable surface, or where contaminants such
as dust, oil, paint vapors, fumes or mist exist. Accumulations of these contaminants
may become hazards to the insulation. These contaminants will provide a fuel
source and will burn when ignited and fire may spread. If a fire has occurred,
the fire retardant chemicals are greatly reduced. Removal of the damaged insulation
must be completed before reapplication. In high humidity applications, swimming
pools, ice rinks, etc., ThermoCon will consider application approval on an individual
job basis.
ThermoCon cannot be held responsible for misapplication of the product. Appearance
and workmanship depend on proper application according to ThermoCon specifications.
ThermoCon warrants ThermoCon’s insulation against defects in material
for a period of one year from the date of purchase of the material from ThermoCon
if stored, handled and installed in accordance with ThermoCon instructions.
ThermoCon makes no expressed warranties except in writing. All implied warranties
of fitness and/or merchantability are expressly excluded. No sales agent, representative
or employee is empowered to change, alter or amend this provision.
Product/information contained in this electronic program is intended for interior
commercial/industrial use. For more information on residential products, contact
ThermoCon.
PLEASE READ INSULATION PACKAGE AND SEPARATE INSTRUCTIONS BEFORE INSTALLATION.
PAY PARTICULAR ATTENTION TO CAUTION LABEL REGARDING SAFE INSTALLATION OF PRODUCT.
|