Trench Covers and Grates – Heavy and Extra Heavy Duty

Trench Covers and Grates in the following series are STANDARD in Iron - furnished in Aluminum when specified.

TCMB and TGMB series are designed for roadway traffic and provide for an H20 wheel loading (32,000 pounds per axle).

TCHB or TGHB series are designed for extra heavy traffic, such as airport aprons and hangers, large forklifts, and extra heavy roadway traffic.

The standard slot openings for these series are 1”.  The water flow calculations for these standard openings are shown below.  Optional 3/8” slot openings can be specified, with lower water flows, for conditions where safe pedestrian pathways are required.


On all series, Covers and Grates are bolted to their Frames for installation in concrete to insure a proper fit after the concrete is placed. The Sheet Metal Form Pan is an optional feature to save the high cost of wood forming in the field. When the Form Pan is specified, it is welded to the Trench Frame. Standard depths for Form Pans are 2” less than the Trench widths (C-2”).



 

Trench Covers and Grates – Heavy and Extra Heavy Duty
Heavy Duty
H20 Wheel Load
Extra Heavy Duty
Loading Specification on Request
C COVER GRATE W D COVER GRATE W D

6
8
10
12
14
16
18
20
22
24
26
28
30
36
42
48

TCMB-6
TCMB-8
TCMB-10
TCMB-12
TCMB-14
TCMB-16
TCMB-18
TCMB-20
TCMB-22
TCMB-24
TCMB-26
TCMB-28
TCMB-30
TCMB-36
TCMB-42
TCMB-48
TGMB-6
TGMB-8
TGMB-10
TGMB-12
TGMB-14
TGMB-16
TGMB-18
TGMB-20
TGMB-22
TGMB-24
TGMB-26
TGMB-28
TGMB-30
TGMB-36
TGMB-42
TGMB-48
8-1/2
10-1/2
12-1/2
14-1/2
16-1/2
18-1/2
20-1/2
22-1/2
24-1/2
27
29
31
33
39
45
51

1-1/2
1-1/2
2
2
2
2
2-1/2
2-1/2
2-1/2
3
3
3
3
3-1/2
3-1/2
3-1/2

TCHB-6
TCHB-8
TCHB-10
TCHB-12
TCHB-14
TCHB-16
TCHB-18
TCHB-20
TCHB-22
TCHB-24
TCHB-26
TCHB-28
TCHB-30
TCHB-36
TCHB-42
TCHB-48
TGHB-6
TGHB-8
TGHB-10
TGHB-12
TGHB-14
TGHB-16
TGHB-18
TGHB-20
TGHB-22
TGHB-24
TGHB-26
TGHB-28
TGHB-30
TGHB-36
TGHB-42
TGHB-48
9
11
13
15
17
19
21
23
25
27
29
31
33-1/2
39-1/2
45-1/2
51-1/2

2
2
2-1/2
2-1/2
3
3
3-1/2
3-1/2
3-1/2
4
4
4
4
5
5-1/2
6

DIMENSIONS IN INCHES. FOR MM, MULTIPLY BY 25.4

Water Flow Table
TRENCH
GRATING
TYPE-TGMB
TRENCH WIDTH
TRENCH
GRATING
TYPE-TGHB
TRENCH WIDTH
"C"
WIDTH
G.P.M.
P.L.FT.
"C"
WIDTH
G.P.M.
P.L.FT.

6
8
10
12
14
16
18
20
22
24
26
28
30
36
42
48

120
133
152
173
229
185
225
248
278
308
374
407
440
424
563
607

6
8
10
12
14
16
18
20
22
24
30
36
42
48

122
164
185
223
181
207
163
274
289
*696
403
444
504
592


Flow Tables are for one inch (1”) if water head.  For two inch (2”) head multiply table figure by 1.25, for three inch (3”) head multiply table figure by 1.5625

Water flow through grates by actual test and by empirical computation.

Where the architect or engineer has a special situation – tell us about it we may be able to work it out for you.