Englert Series 2000 1-3/4" High Structural Snap Lock Standing Seam
is a variable width (12" - 18") integral panel design, with
optional pencil ribs. The variable width feature allows you to specify
whatever width works with your design parameters and exterior aesthetics
(12", 15", 16" & 18" or any infinite width between
12" - 18").
The panel design secures the male interlock hem into the female leg
continuously, lending structural characteristics when applied over purlins
(Cees or Zees). The panel is secured to the purlins or substrate by clips
allowing for unrestricted thermal movement. The clip design provides 1/4"
ventilation clearance between the flat surface of the panel and the
substrate. All fasteners are concealed. Optional sealant ensures greater
watertightness. Installation is fast and simple. No labor intensive
mechanical seaming. Just secure the male leg with clips and snap the
panels in place.
Englert Series 2000 Structural Snap Lock Standing Seam Panel System can
be easily adapted for snap-on-batten applications. With Englert Series
2000 Snap Lock Standing Seam Profile, a 2" high x 1-1/2" wide
continuous batten can simply be snapped in place giving it the snap-on
batten look.
MATERIALS & FINISHES
24 ga. Galvalume conforming to ASTM A-792, AZ-55, 50 KSI yield point or
22 ga. Galvalume, 50 KSI or .032" and .040" aluminum alloy
3105-H14, or equal with baked on PermaColor 2000 in Kynar 500®/Hylar
5000® in all standard
colors or PermaMetallic 2000 metallic coatings in a smooth finish. (See
manufacturer for Color Card and Coating & Finish Processes.)
FLASHING & FLAT STOCK
All exposed flashing to be field formed in the same gauge, finish, color
and texture as the panels. Protective strippable film should be removed at
the time of the installation.
USES & APPLICATIONS
As an integrated roofing system, Englert Series 2000 1-3/4" High
Structural Snap Lock Panels require a pitch of 3"/12" or greater
(check with manufacturer for other slopes). Panels may be installed over
purlins or solid deck with 2 layers of 15# felt. Englert Series 2000
panels may also be installed over metal deck and rigid insulation, with 1
layer of 30# felt, using clips and bearing plates without any purlins. Do
not install panels directly over chemically treated wood.
Extended use of the Englert Series 2000 Panel System can be made for
mansard/equipment screen applications over subgirts or as fascia and
siding/wall system.
Panels should be continuous from ridge to eave and with no end laps.
Horizontal purlins, 2 x 4s or plywood and other decking under the
panel system should be true, plumb and straight. Any deflection may cause
panels to oil can. Such oil canning is not a cause for product refusal.
UL-90 RATINGS
Englert Series 2000 Structural Snap Lock System (12" - 18" wide
panels) meets UL-90 rating in 24 and 22 ga. when applied over 16 gauge
purlins, 4' o.c., with UL-90 clips.
Englert Series 2000 Structural Snap Lock System (12" - 18" wide
panels) meets UL-90 rating in 24 and 22 ga. when applied over 22 ga. metal
deck. Rigid insulation and a layer of 30# felt secured by bearing plates
at 4' o.c. Clips fastened to the deck through the insulation. Horizontal
purlins are not required. Check with Englert for details.
ASTM E-330-84: Englert Series 2000 Panel System meets the test criteria
in accordance with pleated air bag testing (modified ASTM E-330) methods
and the pertinent requirements of the South Florida Building Code 1988
Edition Section 2309.2 (a) Table 23-C for roofing applications. ASTM
E-331-84 water penetration. ASTM E-283-84 air infiltration.
SPECIFICATIONS
NOTE TO SPECIFIER: Englert Series 2000 Panel System serves the
structural needs of roofing/fascia, mansard, siding and soffit systems.
The Series 2000 may be specified for application over solid deck or over
purlins or over metal deck with rigid insulation. The Series 2000 Panel
System can also be secured with bearing plates and clips through the
insulation to the metal deck. Minimum Pitch: 3"/12". Specify as
required.
A. Panel System shall be the Englert Series 2000, 1-3/4" high, 18"
wide, Structural Standing Seam Snap-Lock System (with pencil ribs,
optional), with sealant applied at the panel interlock; specify "with
battens" if you wish a batten appearance. The panels shall have baked
on finish as specified in "Materials & Finishes," in
manufacturers standard colors. Manufacturer shall offer a minimum of
23 standard colors from which to choose.
B. Substrate
- 24 gauge baked on finish over Galvalume ASTM A-792-83, AZ-55, 40
KSI yield point, 52 KSI tensile strength.
- * 22 gauge baked on finish over Galvalume per ASTM A-792-83,
AZ-55, 40 KSI yield point, 52 KSI tensile strength.
- * .032" or .040" Aluminum Alloy 3105-H14 approved
equal.
* NOTE TO SPECIFIER: 22 gauge steel and .032" and
.040" aluminum are available subject to minimum order requirements.
Call Englert for details.
C. Performance
1. Panel shall meet the requirements of Underwriters Laboratories, Inc.
for Class 90 wind uplift resistance.
2. Air infiltration: No greater than 0.014 CFM/Ft² at a test
pressure of 1.57 PSF and 0.009 CFM/Ft² at a test pressure of 6.24 PSF
per ASTM E-283-73.
3. Water resistance: When tested for 5 gallons per minute spray for 15
minutes duration at each test pressure of 1.57 PSF, 6.24 PSF, 12.5 PSF and
15.1 PSF, there shall be no evidence of water penetration, per ASTM
E-331-70.
4. Panel shall display a flame spread classification of a Class 1, when
tested in accordance with ASTM E-84-87.
5. Panel shall be tested and conform to the requirements of the
modified ASTM E-330 static pressure differential test.
6. Panel shall be tested and conform to the requirements of the Dade
County Florida non-structural roofing system criteria; product approval
number must be supplied for record.
Englert, Inc.
1200 Amboy Avenue
P.O. Box 149
Perth Amboy, NJ 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
Email: englert.inc@prodigy.net
Web site: http://www.englertinc.net
Englert, Inc.
Colorado
Phone: (303) 288-8070
Connecticut
Phone: (203) 265-6704
Florida
Phone: (813) 248-2296
Massachusetts
Phone: (508) 774-0006
New Jersey
Phone: (732) 826-8610
New York
Phone: (516) 491-7700
Pennsylvania
Phone: (412) 461-1355
Tennessee
Phone: (423) 970-0090
Virginia
Phone:
(703) 922-9666
(757) 363-0622