SEMINAR TABLES

Product Description:

Floor mounted cantilevered pedestals support continuous table tops with optional PowerUp for surface access to power and data outlets.

Product Benefits:

  • Novoply construction in the table tops prevents warping
  • K&V Tite Joint fasteners, hardwood spline, and steel splice plates provide for a virtually "seamless" top
  • PowerUp power and data distribution systems provides surface mounted power and data access for lap top users
  • Powder-coating on steel pedestals provides maximum durability
  • Custom table sizes, shapes, and edge details create a unique look
Specifications:

Table Tops
Seminar table tops shall be nominal 1-1/4" thick, warp-resistant construction. To have a center core of 1-1/8" thick Novoply of minimum 45 PCF density. The top surface shall be .040" high-pressure laminate meeting NEMA standards, and the bottom surface, .020" thick backing sheet. Laminate and backing sheet shall be permanently bonded to the particleboard core using a cross-linking Poly Vinyl Acetate (PVA) adhesive under continuous pressure in a hot press. Edges shall be slotted to receive extruded-vinyl bullnose with molding 1-1/4" wide with barbed "T" inserted into a routed groove in the solid Novoply core and held in place with nails spaced approximately 12" apart, driven into the "T" from the underside. The table top ends shall have corners with minimum 1-1/2" radius. Continuous table top joints shall be secured with a minimum of two mechanical fasteners equal to Knape & Voight #516, hardwood spline, and heavy-gauge steel plate under joint. Standard depth shall be 18". Available in choice of straight, truncated or radiused configurations in custom lengths to match the room layout. Tops shall have cutouts to accept PowerUp modules when PowerUp is specified.

End Panels
Seminar table end panels shall be nominal .810" thick warp-resistant construction. Center core shall be .75" thick Novoply particleboard, minimum of 45 PCF density. The front surface shall be minimum of .040" thick high-pressure laminate meeting NEMA standards, and the back surface, .020" thick backing sheet. Edges shall be slotted to receive extruded-vinyl bullnose molding 7/8" wide with barbed "T" inserted into a routed groove in the solid Novoply core, and held in place with nails spaced approximately 8" apart, driven into the "T" from the back. The ends shall have corners with minimum 1-1/2" radius. End panels shall be secured to the table top with L-shaped brackets and screws (furnished). Standard height is 14". Full length end panels shall be 1-1/4" thick, warp-resistant construction. To have a center core of 1-1/8" thick Novoply of minimum 45 PCF density. Outer surface shall be .040" high-pressure laminate meeting NEMA standards, and the inner surface, .020" thick backing sheet. Laminate and backing sheet shall be permanently bonded to the particleboard core using a cross-linking Poly Vinyl Acetate (PVA) adhesive under continuous pressure in a hot press. Edges shall be slotted to receive extruded-vinyl bullnose on all four sides with molding 1-1/4" wide with barbed "T" inserted into a routed groove in the solid Novoply core and held in place with nails spaced approximately 12" apart, driven into the "T" from the underside. Other standard table edges inlude PVC, self edge, tread edge, impact edge, and various wood edge styles. Full-length end panels shall be secured to the table top with L-shaped brackets and screws (furnished) and shall have adjustable floor glides.

Modesty Panels
Seminar table modesty panels shall be nominal .810" thick warp-resistant construction in straight or curved configurations. Center core shall be .75" thick Novoply particleboard, minimum of 45 PCF density. The front surface shall be minimum of .040" thick high-pressure laminate meeting NEMA standards, and the back surface, .020" thick backing sheet. Edges shall be slotted to receive extruded-vinyl bullnose molding 7/8" wide with barbed "T" inserted into a routed groove in the solid Novoply core, and held in place with nails spaced approximately 8" apart, driven into the "T" from the back. The modesty panel ends shall have corners with minimum 1-1/2" radius. Modesty panels are segmented with 1/2" space between panels in conjunction with table joints. Modesty panels shall be secured to the table top with L-shaped brackets and screws (furnished). Optional continuous modesty panels are available. Optional Perforated Dteel or Dimpled Steel Modesty panels shall be constructed of 14-gauge steel with .75" hems on horizontal edges. Straight or curved configurations are available in non-continuous panels. Perforated steel panels shall have .25" holes on .75" spacing. Dimpled steel panels shall have .08" deep dimples recessed on 1.5" spacing. Finish shall be clear coat or powdercoat in 5 standard colors.

Optional Perforated Wood Veneer Modesty Panels shall be available as continuous panels in straight or curved configurations. Finish shall be Clear Oak, Clear Maple, Cherry stain on Maple, Mahogany Stain on Maple, or Walnut stain on Maple.

Fixed Bases For Seminar Tables
Fixed pedestal bases for Seminar tables are furnished in a standard 27-3/4" height to be used with 1-1/4" thick tops for a 29" overall table height. Bases shall be cantilever-type pedestal, rectangular-fabricated steel column, 11-gauge, 2" x 4" tubular steel, welded to an 11-gauge, 6" x 8" stamped-steel floor flange and topped with a support arm, 11-gauge, 13-3/4" x 1-1/2" to support the top. Each arm shall have four tabs pierced with holes to secure the top to the base with four screws (furnished) and shall have a notched section on both sides to allow for electrical components and data wires to pass through. Bases shall be specified with a 2" x 4" cutout on the back side of the base at the bottom to allow for power or communication/data cable access. Clear opening space within base is 1-13/16" x 3-13/16" to allow for power or communication/data cables. Cutout shall have a metal cover painted to match the base. Four 7/16" holes are provided in the floor plate for anchoring to the floor.

Escutcheon plates are furnished on all table pedestals. Nonstandard table base heights are available (contact factory). Sloped floor from 0-8 degrees can be accommodated. Floor mounting anchors are not included.

PowerUp
PowerUp Module - The PowerUp module shall be 6-1/4" long x 3" wide x 2-1/2" high. The module shall be constructed of polycarbonate with a textured finish, meeting UL-VO minimum requirements. The module shall have one duplex receptacle (110 volts) and two ports for data connectors (not furnished). The standard module will accommodate various connectors. The data connectors and wires shall be provided by the customer. The module shall have a positive-locking device in the open position to allow the unit to remain open when in use and shall be able to close when not in use. The power receptacles shall be located on a vertical plane when in use to avoid accidental spills into the receptacle. The data connectors shall remain in a stationary position in the module. A cord with a three-prong plug, 22" long, shall plug into the 8-wire harness.

8-Wire Harness - The 8-wire harness of flexible conduit shall distribute power between the power/data modules and the power infeed. The harness shall be enclosed in a plastic trough with a metal divider to separate power and communication or data cables. The trough shall be constructed of rigid PVC approximately .06" thick. The trough shall be attached to the underside of the surface (by the installer) with wood screws provided. The trough shall measure 1.34" deep x 6.2" wide overall with an interior dimension of 5.5 cubic inches. The trough shall include a 24-gauge L-shaped metal divider measuring 1-1/4" x 1-1/4" and shall be attached to a groove in the trough. The trough shall be available in black only.

Receptacle Shroud Cover - The receptacle shroud cover shall be made of PVC meeting UL 94-HB, 12" x 14" x 2" vacuum-formed to house the connection of the 8-wire harnesses and the cord from the PowerUp module. A 1-13/16" x 3" opening in the shroud shall allow access to the duplex receptacle. A 1¼" radiused slot shall allow access for removal of the PowerUp module. Black only.

All electrical components shall be installed on site with hardware provided. A licensed electrician is required to connect the power infeed to the building power source.

All PowerUp components are UL Listed for use on Seminar tables.
Colors
Frame finishes - Powder-coated finish is standard on all frames in a choice of black, sand, warm grey, and blue grey. Plastic trim components match the four standard powder-coated colors unless otherwise specified. Vinyl bullnose edge on tops and modesty panels is available in black, sand, blue grey, and warm grey.

Optional Top Features - Accent strips, name card slots, bookrails, wire management, PowerUp power/data electrical system, multi-level continuous tops and PVC, self-edge or wood edge with square or radius corners are available at additional costs. Contrasting colors between table tops and modesty panel can be specified.

Optional Top Depth and Modesty Panels depth - Minimum top depth is 18". Maximum top depth 24" (without additional support). Minimum modesty panel depth 9", maximum full height with additional bracketry.

Note: Floor-mounting anchors are not provided.
 

INSTALLATION SECTION

FLOOR MOUNTING REQUIREMENTS

Minimum Construction Required for Upright Installation

Wood Floors
� Minimum two layers of 3/4" thickness tongue & groove
� APA rated grade plywood
� Allow minimum embedment 1-1/2" with lag screws
� Use toggle bolt if less than 1-1/2" embedment

Concrete Floors
� 3000 psi Concrete compressive strength
� 3" thick free of obstructions for 1-1/2"
� 4" thick for riser mount free of obstructions for 2-1/2"
� Riser to be plumb within 1/8 degree
� Minimum anchor embedment 1-1/2"

Note: Warranty null and void if KI product is installed on flooring not meeting minimum structural requirements stated above.

Floor Fastener Requirements

Wood Floors
� 5/16" x 1-3/4" lag bolts; grade 5
� 5/16" flat washers
� 3/8" toggle bolts
� All hardware to be plated
� Four bolt assemblies required per base

Concrete Floors
� 5/16"-18 or 3/8"-16 grade 5 expansion anchors
� Standard flat washers, plated
� LockTite (red) thread lock or equal
� Four screw assemblies required per base

Note: Floor mounting fasteners are not provided.