KI
1330 Bellevue Street
Green Bay, WI 54302
Tel: (920) 468-8100
Fax: (920) 468-0280
E-mail: consultki@ki.com
Web site: www.ki.com
SEMINAR TABLES
Product Description:
Floor mounted cantilevered pedestals
support continuous table tops with optional PowerUp for surface access
to power and data outlets.
Product Benefits:
-
Novoply construction in the table tops
prevents warping
-
K&V Tite Joint fasteners, hardwood
spline, and steel splice plates provide for a virtually "seamless" top
-
PowerUp power and data distribution
systems provides surface mounted power and data access for lap top users
-
Powder-coating on steel pedestals provides
maximum durability
-
Custom table sizes, shapes, and edge
details create a unique look
Specifications:
Table Tops
Seminar table tops shall be nominal
1-1/4" thick, warp-resistant construction. To have a center core of 1-1/8"
thick Novoply of minimum 45 PCF density. The top surface shall be .040"
high-pressure laminate meeting NEMA standards, and the bottom surface,
.020" thick backing sheet. Laminate and backing sheet shall be permanently
bonded to the particleboard core using a cross-linking Poly Vinyl Acetate
(PVA) adhesive under continuous pressure in a hot press. Edges shall be
slotted to receive extruded-vinyl bullnose with molding 1-1/4" wide with
barbed "T" inserted into a routed groove in the solid Novoply core and
held in place with nails spaced approximately 12" apart, driven into the
"T" from the underside. The table top ends shall have corners with minimum
1-1/2" radius. Continuous table top joints shall be secured with a minimum
of two mechanical fasteners equal to Knape & Voight #516, hardwood
spline, and heavy-gauge steel plate under joint. Standard depth shall be
18". Available in choice of straight, truncated or radiused configurations
in custom lengths to match the room layout. Tops shall have cutouts to
accept PowerUp modules when PowerUp is specified.
End Panels
Seminar table end panels shall be nominal .810"
thick warp-resistant construction. Center core shall be .75" thick Novoply particleboard,
minimum of 45 PCF density. The front surface shall be minimum of .040" thick
high-pressure laminate meeting NEMA standards, and the back surface, .020" thick
backing sheet. Edges shall be slotted to receive extruded-vinyl bullnose molding
7/8" wide with barbed "T" inserted into a routed groove in the solid Novoply
core, and held in place with nails spaced approximately 8" apart, driven into
the "T" from the back. The ends shall have corners with minimum 1-1/2" radius.
End panels shall be secured to the table top with L-shaped brackets and screws
(furnished). Standard height is 14". Full length end panels shall be 1-1/4"
thick, warp-resistant construction. To have a center core of 1-1/8" thick Novoply
of minimum 45 PCF density. Outer surface shall be .040" high-pressure laminate
meeting NEMA standards, and the inner surface, .020" thick backing sheet. Laminate
and backing sheet shall be permanently bonded to the particleboard core using
a cross-linking Poly Vinyl Acetate (PVA) adhesive under continuous pressure
in a hot press. Edges shall be slotted to receive extruded-vinyl bullnose on
all four sides with molding 1-1/4" wide with barbed "T" inserted into a routed
groove in the solid Novoply core and held in place with nails spaced approximately
12" apart, driven into the "T" from the underside. Other standard table edges
inlude PVC, self edge, tread edge, impact edge, and various wood edge styles.
Full-length end panels shall be secured to the table top with L-shaped brackets
and screws (furnished) and shall have adjustable floor glides.
Modesty Panels
Seminar table modesty panels shall be nominal .810"
thick warp-resistant construction in straight or curved configurations. Center
core shall be .75" thick Novoply particleboard, minimum of 45 PCF density. The
front surface shall be minimum of .040" thick high-pressure laminate meeting
NEMA standards, and the back surface, .020" thick backing sheet. Edges shall
be slotted to receive extruded-vinyl bullnose molding 7/8" wide with barbed
"T" inserted into a routed groove in the solid Novoply core, and held in place
with nails spaced approximately 8" apart, driven into the "T" from the back.
The modesty panel ends shall have corners with minimum 1-1/2" radius. Modesty
panels are segmented with 1/2" space between panels in conjunction with table
joints. Modesty panels shall be secured to the table top with L-shaped brackets
and screws (furnished). Optional continuous modesty panels are available. Optional
Perforated Dteel or Dimpled Steel Modesty panels shall be constructed of 14-gauge
steel with .75" hems on horizontal edges. Straight or curved configurations
are available in non-continuous panels. Perforated steel panels shall have .25"
holes on .75" spacing. Dimpled steel panels shall have .08" deep dimples
recessed on 1.5" spacing. Finish shall be clear coat or powdercoat in 5
standard colors.
Optional Perforated Wood Veneer Modesty Panels shall be available as continuous
panels in straight or curved configurations. Finish shall be Clear Oak, Clear
Maple, Cherry stain on Maple, Mahogany Stain on Maple, or Walnut stain on Maple.
Fixed Bases For Seminar Tables
Fixed pedestal bases for Seminar
tables are furnished in a standard 27-3/4" height to be used with 1-1/4"
thick tops for a 29" overall table height. Bases shall be cantilever-type
pedestal, rectangular-fabricated steel column, 11-gauge, 2" x 4" tubular
steel, welded to an 11-gauge, 6" x 8" stamped-steel floor flange and topped
with a support arm, 11-gauge, 13-3/4" x 1-1/2" to support the top. Each
arm shall have four tabs pierced with holes to secure the top to the base
with four screws (furnished) and shall have a notched section on both sides
to allow for electrical components and data wires to pass through. Bases
shall be specified with a 2" x 4" cutout on the back side of the base at
the bottom to allow for power or communication/data cable access. Clear
opening space within base is 1-13/16" x 3-13/16" to allow for power or
communication/data cables. Cutout shall have a metal cover painted to match
the base. Four 7/16" holes are provided in the floor plate for anchoring
to the floor.
Escutcheon plates are furnished on
all table pedestals. Nonstandard table base heights are available (contact
factory). Sloped floor from 0-8 degrees can be accommodated. Floor mounting
anchors are not included.
PowerUp
PowerUp Module - The PowerUp module shall be 6-1/4"
long x 3" wide x 2-1/2" high. The module shall be constructed of polycarbonate
with a textured finish, meeting UL-VO minimum requirements. The module shall
have one duplex receptacle (110 volts) and two ports for data connectors (not
furnished). The standard module will accommodate various connectors. The data
connectors and wires shall be provided by the customer. The module shall have
a positive-locking device in the open position to allow the unit to remain open
when in use and shall be able to close when not in use. The power receptacles
shall be located on a vertical plane when in use to avoid accidental spills
into the receptacle. The data connectors shall remain in a stationary position
in the module. A cord with a three-prong plug, 22" long, shall plug into the
8-wire harness.
8-Wire Harness - The 8-wire harness
of flexible conduit shall distribute power between the power/data modules
and the power infeed. The harness shall be enclosed in a plastic trough
with a metal divider to separate power and communication or data cables.
The trough shall be constructed of rigid PVC approximately .06" thick.
The trough shall be attached to the underside of the surface (by the installer)
with wood screws provided. The trough shall measure 1.34" deep x 6.2" wide
overall with an interior dimension of 5.5 cubic inches. The trough shall
include a 24-gauge L-shaped metal divider measuring 1-1/4" x 1-1/4" and
shall be attached to a groove in the trough. The trough shall be available
in black only.
Receptacle Shroud Cover - The receptacle
shroud cover shall be made of PVC meeting UL 94-HB, 12" x 14" x 2" vacuum-formed
to house the connection of the 8-wire harnesses and the cord from the PowerUp
module. A 1-13/16" x 3" opening in the shroud shall allow access to the
duplex receptacle. A 1¼" radiused slot shall allow access for removal
of the PowerUp module. Black only.
All electrical components shall be
installed on site with hardware provided. A licensed electrician is required
to connect the power infeed to the building power source.
All PowerUp components are UL Listed
for use on Seminar tables.
Colors
Frame finishes - Powder-coated finish
is standard on all frames in a choice of black, sand, warm grey, and blue
grey. Plastic trim components match the four standard powder-coated colors
unless otherwise specified. Vinyl bullnose edge on tops and modesty panels
is available in black, sand, blue grey, and warm grey.
Optional Top Features - Accent strips,
name card slots, bookrails, wire management, PowerUp power/data electrical
system, multi-level continuous tops and PVC, self-edge or wood edge with
square or radius corners are available at additional costs. Contrasting
colors between table tops and modesty panel can be specified.
Optional Top Depth and Modesty Panels depth -
Minimum top depth is 18". Maximum top depth 24" (without additional support).
Minimum modesty panel depth 9", maximum full height with additional bracketry.
Note: Floor-mounting anchors are
not provided.
INSTALLATION SECTION
FLOOR MOUNTING REQUIREMENTS
Minimum Construction Required
for Upright Installation
Wood Floors
� Minimum two layers of 3/4" thickness
tongue & groove
� APA rated grade plywood
� Allow minimum embedment 1-1/2"
with lag screws
� Use toggle bolt if less than 1-1/2"
embedment
Concrete Floors
� 3000 psi Concrete compressive
strength
� 3" thick free of obstructions
for 1-1/2"
� 4" thick for riser mount free
of obstructions for 2-1/2"
� Riser to be plumb within 1/8 degree
� Minimum anchor embedment 1-1/2"
Note: Warranty null and void if KI
product is installed on flooring not meeting minimum structural requirements
stated above.
Floor Fastener Requirements
Wood Floors
� 5/16" x 1-3/4" lag bolts; grade
5
� 5/16" flat washers
� 3/8" toggle bolts
� All hardware to be plated
� Four bolt assemblies required
per base
Concrete Floors
� 5/16"-18 or 3/8"-16 grade 5 expansion
anchors
� Standard flat washers, plated
� LockTite (red) thread lock or
equal
� Four screw assemblies required
per base
Note: Floor mounting fasteners are
not
provided.
|