REDI-ROOF Standing Seam & Batten Seam Metal Roofing

Redi-Roof is an architectural metal roofing system available exclusively from Petersen Aluminum Corporation. It may be specified in either a batten or standing seam profile and is intended for application over a solid substrate with a minimum 3:12 roof pitch. Typical underlayments include plywood, nailboard insulation or equal. Panels are to be factory roll-formed in continuous lengths (minimum panel length is 4 feet).

Redi-Roof Panels feature an offset profile which adds strength and allows room for a hex head fastener. The clip, with its button punched design, insures an extra-snug fit. RediRoof panels are Herr-Voss corrective leveled to provide superior flatness. The one-piece design of the Redi-Roof Standing Seam allows for ease of installation.

SNAP-ON Panels are available with:

  • Stiffener beads
  • Factory eave notching
  • With or without offsets

Batten Seam
REDI-ROOF Panels are available with a Batten Seam.

Installation
PAC-CLAD Redi-Roof shall be installed over solid decking with an underlayment of 30# (min.) roofing felt applied horizontally from eave to ridge. Panels shall be fastened using Petersen non-penetrating clips, fastening on 18" centers (max.). Minimum slope at 3:12 pitch.

Redi-Roof Batten panels cannot be lapped in the field. Consult a local architect/engineer for requirements of local codes and conditions.

Curved Panels
The Redi-Roof Batten Panel is the industry's only batten panel which can be radiused concave or convex with a minimum radius of 9 ft. This panel is ideal for barrel vaults and cornices. Curved panels must be installed over a waterproofed solid substrate.

UL Designations
Steel Redi-Roof Panels carry a UL-90 classification for wind uplift when fastened to an underlayment assembly including 5/8" plywood or OSB (oriented strand board) laminated to rigid insulation (UL Construction No. 350 & 353)). For further details contact Petersen Aluminum Corporation.

  • UL-580 Class 90 rated over solid substrate
  • UL-790 Class A fire rated
  • UL-263 fire resistance rated
  • UL-2218 impact resistance rated
ASTM Testing
Petersen Redi-Roof Panels meet the full performance requirements of the ASTM E 283 air infiltration test and the ASTM E 331 water penetration test when applied over a solid substrate. For complete test results, contact Petersen Aluminum Corporation.

Materials

  • 24 ga. G-90 hot dipped galvanized steel
  • .032 3105-H14 aluminum or equal
  • 16 oz. cold rolled copper (standing seam only)
Finishes

  • 24 Gauge Steel: 42 Standard Colors
  • Aluminum: 37 Standard Colors
  • Smooth and stucco embossed textures
  • 20-year non-prorated finish warranty
  • Galvalume Plus available on indicate panel types
Trim
All flashing and trim will be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032-.080 gauge as specified) or PAC-CLAD steel (22 ga. or 24 ga. as specified). A 20 year warranty shall be supplied covering finish performance.


Petersen Aluminum Corporation
1005 Tonne Road
Elk Grove Village, IL 60007
Toll-Free: 800-PAC-CLAD
Fax: 800-722-7150 or 847-956-7968
Web site: http://www.pac-clad.com