ENERGY GUARD PERLITE® RECOVER BOARD
Formerly BMCA Permalite®Recover Board
DESCRIPTION
EnergyGuard Perlite Recover Board is a heavier duty 1/2" thick perlite
roof insulation board composed of expanded perlite, cellulose binders,
and waterproofing agents. It is treated for surface retention of bitumen
and available in 2' x 4' (0.61m x 1.22m), 4' x 4' (1.22m x 1.22m) and 4'
x 8' (1.22m x 2.44m), with a nominal thickness of 1/2 " (13mm).
USES
In reroofing as a base for a variety of membranes installed over
failed or worn out roof systems.
As a top layer in two layer systems.
As an overlay board where an existing roof insulation is still functioning
and should be retained.
Where a tear-off would create unwarranted risks to operations or
materials in the building.
To separate a new membrane from a rough or irregular deck.
Properly installed, EnergyGuard Perlite Recover Board roof insulation
is suitable for use under built-up, modified bitumen and some single ply
roofing systems.
BENEFITS
Economical base for reroofing.
Protects new roofs from old roof problems.
Lower installed cost than tear-offs.
Dimensionally stable.
Environmentally friendly. The minimum recycled content is 25% by
weight.
CODE COMPLIANCE
Recover Board is in compliance with:
ASTM Standard C728.
UL Class A construction on combustible or non-combustible roof decks.
Where UL labels are required, customer must order them in advance.
FMRC for fire and wind resistance. Contact the Contractor Services
Department at 1-800-624-6832 for the latest approvals.
Complies with the Environmental Protection Agency Regulation 40 CFR
Part 248, Guideline for Federal Procurement of Building Insulation Products
Containing
Recovered Materials, as a recycled product approved for use on any
project using federal funds.
APPLICATION
Recover Board can be secured by mechanical fastening or hot asphalt.
If the deck is non-nailable, strip mopping is recommended to allow for
moisture pressure release. Solid mopping with asphalt should not be
used for re-roofing applications. Refer to the application specifications
in the current membrane manufacturers Application and Specifications manual
for proper installation procedures.
LIMITATIONS
Old roofing systems must be thoroughly dried and secured before Recover
Board is applied as a part of a new roof system.
Recover Board is not acceptable for applications where it will be
directly exposed to continuous soaking temperatures in excess of 250°F.
EnergyGuard Perlite roof insulation is a non-structural, non-load
bearing material.
EnergyGuard Perlite roof insulation should not be left exposed to
the weather.
No more insulation should be applied than can be completely covered
with finished roofing on the same day.
Do NOT use under fully adhered single ply systems or with direct
torch application of modified bitumen.
If torch grade, modified bitumen roofing is to be installed over
EnergyGuard Perlite, a fiber glass base sheet MUST first be installed.
Do NOT mechanically attach 1/2 inch recover board directly to steel
decks.
THERMAL VALUES (1)
Thickness
(nominal) in mm |
C value
(Conductance) BTU/(hrft2°F) W/m2°C |
R-Value
(Resistance) (hrft2°F)/BTU m2°C/W |
13 | 0.76 4.3 | 1.32 0.23 |
TYPICAL PHYSICAL PROPERTIES (1)
Typical Physical Properties | Value | Test Method |
Water Absorption, % by Volume
2 hrs. |
3.5 max. | ASTM C 209 |
Compression Resistance
5% Consolidation psi (kPa) 10% Consolidation psi (kPa) |
35 (241)
50 (345) |
ASTM C 165 |
Laminar Tensile Strength psi (kPa) | 4.9 (33.8) | ASTM C 209 |
Flexural Strength psi (kPa) | 60 (414) | ASTM C 203 |
Product Density pcf (kg/m3) | 11 - 14 (176 - 224) | ASTM C 209 |
Linear Expansion | 0.5% max. | ASTM C 209/
ASTM D 1037 |