![]() ![]() 1 LATICRETE Park North Bethany, CT 06524-3423 USA Telephone: +1.203.393.0010, ext. 235 Toll Free: 1.800.243.4788, ext. 235 Fax: +1.203.393.1948 E-mail: technicalservices@laticrete.com Web site: http://www.laticrete.com LATICRETE® 9235 Waterproofing Membrane PRODUCT DESCRIPTION LATICRETE 9235 Waterproofing Membrane is a thin, load-bearing waterproofing designed specifically for the special requirements of ceramic tile, stone and brick installations. A self-curing liquid rubber polymer and a reinforcing fabric are quickly applied to form a flexible, seamless waterproofing membrane that bonds to a wide variety of substrates. Uses
* Interior Applications Only; Full Unit: (36 Full Units/pallet) consisting of: Full Unit: 300 ft2 (27.8 m2) Factory sealed containers of this product are guaranteed to be of first quality for two (2) years if stored at temperatures >32°F (0°C) and 110°F (43°C). Limitations
Consult MSDS for more safety information.
![]() VOC/LEED Product Information This product has been GREENGUARD Indoor Air Quality Certified® by the GREENGUARD Environmental Institute under the GREENGUARD Standard for Low Emitting Products in finished form. Total VOC Content pounds/gallon (grams/liter) of product in unused form is 0.02 lb /gal (2.39 g/l ). Applicable Standards
* Tile Council of America Service Rating Categories The following overview provides basic installation information. Refer to Data Sheet WPAF.5 (included in unit) for complete instructions or visit www.laticrete.com. Surface PreparationSurface temperature must be 45–90°F (7–32°C) during application and for 24 hours after installation. All substrates must be structurally sound, clean and free of dirt, oil, grease, loose/peeling paint, laitance, efflorescence, concrete sealers or curing compounds. Make rough or uneven concrete smooth to a wood float or better finish with a LATICRETE® Underlayment. Do not level with gypsum or asphalt based products. Maximum deviation in plane must not exceed 1/4" in 10 ft (6 mm in 3 m) with no more than 1/16" in 1 ft (1.5 mm in 0.3 m) variation between high spots. Dampen hot, dry surfaces and sweep off excess waterâinstallation may be made on a damp surface. New concrete slabs shall be damp cured and a minimum of 14 days old before application. Maximum amount of moisture in the concrete substrate should not exceed 5 lbs./1000 square feet (2.26 kg/92.9 m2) 24 hrs. per ASTM F-1869 or 75% relative humidity as measured with moisture probes.
Apply a liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid approximately 8" (200 mm) wide over substrate cracks, cold joints, control joints and board joints using a paint brush or roller (heavy napped roller cover). Place 6" (150 mm) wide LATICRETE Waterproofing/Anti-Fracture Fabric into the wet LATICRETE 9235 Waterproofing Membrane Liquid. Press down on LATICRETE Waterproofing/Anti-Fracture Fabric with brush or roller until the LATICRETE 9235 Waterproofing Membrane Liquid "bleeds" through from below. Then apply another liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid over the entire surface of the LATICRETE Waterproofing/Anti-Fracture Fabric. Pre-Treat Coves, Corners & SeamsApply a liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid approximately 8" (200 mm) wide over substrate coves, corners, seams, joints and changes in plane using a paint brush or roller (heavy napped roller cover). Fold 6" (15 cm) wide LATICRETE Waterproofing/Anti-Fracture Fabric in half and place it into the coat^^ of wet LATICRETE 9235 Waterproofing Membrane Liquid. Flash LATICRETE Waterproofing/Anti-Fracture Fabric 3" (75 mm) up walls and other vertical surfaces. Press down on LATICRETE Waterproofing/Anti-Fracture Fabric with brush or roller until the LATICRETE 9235 Waterproofing Membrane Liquid "bleeds" through from below. Then apply another liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid over the entire surface of the LATICRETE Waterproofing/Anti-Fracture Fabric. When using LATICRETE WPM Fabric Inside Corners and LATICRETE WPM Fabric Outside Corners apply a liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid approximately 8" (200 mm) wide over substrate corners using a paint brush. Place LATICRETE WPM Fabric Inside Corner or LATICRETE WPM Fabric Outside Corner into the wet coat of LATICRETE 9235 Waterproofing Membrane Liquid. Press down on LATICRETE WPM Fabric Inside Corner or LATICRETE WPM Fabric Outside Corner with a brush until the LATICRETE 9235 Waterproofing Membrane Liquid "bleeds" through from below. Then apply another liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid over the entire surface of the LATICRETE WPM Fabric Inside Corner or LATICRETE WPM Fabric Outside Corner. Pre-Treat DrainsDrains must be of the clamping ring type, with weepers and as per ASME A112.6.3. Cut a square of LATICRETE Waterproofing/Anti-Fracture Fabric approximately 38" x 38" (965 mm x 965 mm). In the center of the LATICRETE Waterproofing/Anti-Fracture Fabric square, cut a hole that matches the diameter of the drain throat as closely as possible. Apply a liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid around and over the bottom half of drain clamping ring. Center the circular cutout over the drain throat and imbed the LATICRETE Waterproofing/Anti-Fracture Fabric square into the LATICRETE 9235 Waterproofing Membrane Liquid, encircling the drain throat as closely as possible. Cover with a second coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid. When dry, apply a LATICRETE Latasil™ bead where the LATICRETE Waterproofing/Anti-Fracture Fabric square cutout meets the drain throat. Install top half of drain clamping ring. Pre-Treat PenetrationsPack any gaps around pipes, lights or other penetrations with a compressible backer rod and LATICRETE Latasil. Apply a liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid around penetration opening. Imbed pieces of 6" (150 mm) wide LATICRETE Waterproofing/Anti-Fracture Fabric into LATICRETE 9235 Waterproofing Membrane Liquid. Cover with a second coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid. When dry, seal flashing with LATICRETE Latasil. Main ApplicationAllow any pre-treated areas to dry to the touch. Apply a liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid with brush or roller over substrate including pre-treated areas. Lay LATICRETE Waterproofing/Anti-Fracture Fabric into wet LATICRETE 9235 Waterproofing Membrane Liquid and smooth out any wrinkles. Press LATICRETE Waterproofing/Anti-Fracture Fabric with brush or roller until LATICRETE 9235 Waterproofing Membrane Liquid "bleeds" through to surface. Lap seams approximately 2" (50 mm). Flash LATICRETE 9235 Waterproofing Membrane up over pre-treated coves and corners, so such areas have two layers of LATICRETE Waterproofing/Anti-Fracture Fabric. Apply another liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid over LATICRETE Waterproofing/Anti-Fracture Fabric to saturate it. Let topcoat dry to the touch, approximately 1–3 hours @ 70°F (21°C) and 50% RH. Make another liberal coat^^ of LATICRETE 9235 Waterproofing Membrane Liquid to seal entire surface. When last coat has dried to the touch, inspect final surface for pinholes, voids, thin spots or other defects. Use additional LATICRETE 9235 Waterproofing Membrane Liquid to seal defects. Interior CBU and Gypsum WallboardLATICRETE 9235 Waterproofing Membrane Reinforcing Fabric and the third coat of LATICRETE 9235 Waterproofing Membrane Liquid may be omitted from main applications over interior walls and other vertical surfaces made with cementitious backer units (CBU) or gypsum wallboard. However, coves, corners, seams and board joints must be pre-treated as described above. Expansion JointsApply a liberal coat^^ of LATICRETE® 9235 Waterproofing Membrane Liquid around and down into substrate expansion joints. Loop 6" (150 mm) wide LATICRETE 9235 Waterproofing Membrane Reinforcing Fabric down into joint. Cover with a second layer of LATICRETE 9235 Waterproofing Membrane Liquid^^. ^ Refer to Limitations section for unacceptable cracks; Provide protection for newly installed membrane, even if covered with a thin bed ceramic tile, stone or brick installation, againstexposure to rain or other water for a minimum of 5 days @ 70°F (21°C)and 50% RH. Flood TestingAllow membrane to cure fully before flood testing, typically 7 days @ 70°F (21°C) and 50% RH. Cold and/or wet conditions will require a longer curing time. Installing FinishesOnce LATICRETE 9235 Waterproofing Membrane has dried to the touch, ceramic tile, stone or brick may be installed by the thin bed method with a LATICRETE Latex Thin-Set Mortar. Allow LATICRETE 9235 Waterproofing Membrane to cure 7 days at 70°F (21°C) and 50% RH before covering with concrete, thick bed mortar, screeds, toppings, coatings, epoxy adhesives, terrazzo or moisture sensitive resilient or wood flooring. DO NOT use solvent-based adhesives directly on LATICRETE 9235 Waterproofing Membrane. Drains & PenetrationsAllow for a minimum 1/4" (6 mm) space between drains, pipes, lights or other penetrations and surrounding ceramic tile, stone or brick. Use LATICRETE Latasil™ and foam backer rod to seal space–do not use a grout or joint filler mortar. Control JointsCeramic tile, stone and brick installations must include sealant filled joints over any control joints in the substrate. However, the sealant filled joints can be offset horizontally, by as much as one tile width from the substrate control joint location, to coincide with the grout joint pattern. Expansion JointsCeramic tile, stone and brick installations must include expansion joints at coves, corners, other changes in substrate plane and over any expansion joints in the substrate. Expansion joints in ceramic tile, stone or brickwork are also required at perimeters, at restraining surfaces, at penetrations and at the intervals described in Tile Council of North America, Inc. (TCNA) Handbook Installation Method EJ171. Use LATICRETE Latasil and backer rod. CleaningWhile wet, LATICRETE 9235 Waterproofing Membrane Liquid can be washed from tools with water. ![]() Availability LATICRETE and LATAPOXY® materials are available worldwide. Contact a LATICRETE/LATAPOXY Distributor in your area. WARRANTYSee 10. FILING SYSTEM MAINTENANCELATICRETE and LATAPOXY grouts require routine cleaning with a neutral pH soap and water. All other LATICRETE and LATAPOXY materials require no maintenance but installation performance and durability may depend on properly maintaining products supplied by other manufacturers. TECHNICAL SERVICESTechnical assistance Information is available by calling: To acquire technical and safety literature, please visit our website at www.laticrete.com. FILING SYSTEMAdditional product information is available on our website at www.laticrete.com. The following is a list of related documents:
|