PDQ Manufacturing -Exit Devices Electrified Trim

DOWNLOADS

Motorized Locking/Unlocking (Fail Secure/Fail Safe)

FAIL SECURE (Factory Default)- Outside trim is UNLOCKED when power is ON, and LOCKED when power is OFF. Lockset will lock in the event of a power failure.


Category: crash bars | exit device hardware | panic bars...

MasterFormat: Hardware | Door Hardware | Exit Devices*



PDQ Manufacturing
2230 Embassy Drive
Lancaster, PA 17603
Tel: (800) 441-9692
Fax: (717) 656-6892

kimwanamaker@pdqlocks.com

https://www.pdqlocks.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Exit Devices Electrified Trim

Motorized Locking/Unlocking (Fail Secure/Fail Safe)

FAIL SECURE (Factory Default)- Outside trim is UNLOCKED when power is ON, and LOCKED when power is OFF. Lockset will lock in the event of a power failure.

FAIL SAFE - Outside trim is LOCKED when power is ON, and UNLOCKED when power is OFF. Lockset will unlock in the event of a power failure.


See More


Specifications

Features:

  • Motorized locking/unlocking.
    FAIL SECURE (Factory Default)- Outside trim is UNLOCKED when power is ON, and LOCKED when power is OFF. Lockset will lock in the event of a power failure. FAIL SAFE - Outside trim is LOCKED when power is ON, and UNLOCKED when power is OFF. Lockset will unlock in the event of a power failure.
  • Field changeable from FAIL Secure to FAIL SAFE.
  • Built around PDQ’s world class 6 EW Series Exit Device Trim.
  • Designed for AC or DC input voltage. No need to select voltage when specifying or ordering.
  • SMARTSENSE™ control board automatically accepts AC or DC input voltage.

Performance:

  • Motor drive factory tested to over 1.4 million cycles(1.4 times the ANSI/BHMA grade 1 std).

Recommended Power Supply:

  • PDQ Model # 81440.
    - Input: 120VAC, .9A, 50/60Hz 240VAC, .6.A, 50/60Hz
    - Output: 24VDC, 2A, filtered and regulated.
  • Rated for simultaneous operation of 2ea 6 EW 199A assemblies.
  • Power Supply Requirements:
    - AC/DC Output Voltage - 1A min (filtered and regulated).
  • 12-24VDC @ < 1A initial surge (1 sec), 5mA standby after 30 sec.
    - AC Output Voltage.
  • 12-24VAC (60Hz) @ < 1A initial surge (1 sec), 15mA standby after 30 sec

Electrical Specifications:Note: Operating voltage at ± 10% of rated voltage.

  • Input voltage: 12-24VDC or 12-24VAC.
  • Max In-rush current: < 1.0A.
  • Standby current:
    - 12VAC: 12mA.
    - 24VAC: 10mA.
    - 12VDC: 3mA.
    - 24VDC: 5mA.

Certifications, Compliances, Listings:

  • ANSI/UL10C and CAN/ULC-5104 Listed for “Fire Exit Hardware” up to 3 hours for 4’0” x 8’0” maximum single, 8’0” x 8’0” maximum pairs.
  • Assembled in the U.S.A. with U.S. and foreign material. Meets requirements of the Buy American Act.

Additional options:

  • Latch Bolt Monitoring.
  • Alarms.
  • Signal Switches.

Sweetsstakes