Tectum Inc. - Fabri-Tough™ II Wall Panels

Tectum Fabri-Tough II allows designers to use any suitable fabric on sound-deadening Tectum Wall Panels. Custom Fabrics and a 1/8 inch, 18-pound density fiberglass board are laminated to the face of a Tectum Wall Panel. Fabri-Tough II is perfect for offices, conference rooms and any space where...


MasterFormat: Wood Wall Coverings | Fabric-Wrapped Panels | Interior Wall Paneling...



Tectum Inc.
P. O. Box 3002
Newark, OH 43058
Tel: (888) 977-9691
Fax: (800) 832-8869

info@tectum.com

http://www.tectum.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview



Fabri-Tough™ II Wall Panels

Fabri-Tough™ II Wall Panels

Tectum Fabri-Tough II allows designers to use any suitable fabric on sound-deadening Tectum Wall Panels. Custom Fabrics and a 1/8 inch, 18-pound density fiberglass board are laminated to the face of a Tectum Wall Panel. Fabri-Tough II is perfect for offices, conference rooms and any space where noise reduction is needed and designer fabrics are desired. In spaces where even greater sound absorption is needed, Finalé Fabri-Tough II provides an NRC up to .85 without sacrificing style.

Control noise efficiently, economically and attractively in open plan, closed or mixed-use space with the Fabri-Tough II Wall Panel System. Efficiently - Tectum panels are known for sound absorption and abuse-resistance. Economically - these panels are competitively priced and will last longer than ordinary, soft- base panels. Attractively - the designer specifies desired fabric brand and pattern.

Fabri-Tough II Kerfed Wall Panels have the fabric wrapped around the edge to the kerf where a plastic spline is inserted for attachment to the wall. Panel ends are square cut but can be wrapped with the fabric as an option.

Fabri-Tough II Décor Panels have fully wrapped edges and are attached using 20” Z-Clips allowing for panels to be strategically placed in a space as opposed to consecutive attachment. Fabri-Tough II Wall Panels have a flame spread of 25 or less under the ASTM E84 test method. Panel components meet the requirements of the room corner fire test (UBC 8-2 or equivalent) for use in areas not protected by automatic sprinklers.

For panels used in recessed areas, some field adjusting may be necessary.

Technical Data

NRC/Mountings - Noise Reduction
Up to 1.00 NRC can be achieved depending on mounting style. Furring strips installed horizontally (when using vertical panels) are recommended and should be a maximum of 24" o.c. when using 1"-thick panels.

  • Tectum Fabri-Tough II Wall Panels Acoustical (NRC) Data Download
  • "A" Mounting
  • "D-20" Mounting
  • "C-20" Mounting
  • "C-40" Mounting

Installation Instructions

  • I-1 Fabri-Tough II Wall Panel Installation Instructions (Kerfed)
  • I-4 Fabri-Tough II Wall Panel Installation Instructions (Décor) (Coming Soon)

Drawings

  • Fabri-Tough II Wall Spline Attach Detail
  • Tectum Plastic Spline Detail
  • Fabri-Tough II Décor Panel Attachment (24 Wide) Detail
  • Fabri-Tough II Décor Panel Attachment (48 Wide) Detail
  • Finalé Fabri-Tough II Décor Attachment Horizontal
  • Finalé Fabri-Tough II Décor Attachment Vertical

ASTM E-84 - Flame Spread/Smoke Developed
Tectum Fabri-Tough II Wall Panels - Class A\Class 1 (Component Tested)

Fabric Style and Color Selection:

  • Custom Fabrics (Architect Selects)

SIZES, FINISHES
Tectum Fabri-Tough™ II Wall Panels (kerfed) are available in 23 ¾" width and lengths of 4' up to 10'. Tectum Fabri-Tough™ II Décor Wall Panels are available in 23 ¾" and 47 ¾" width and lengths of 4' up to 10'.

Weights

  • 1" - 1.65 lbs./square foot
  • 1½" - 2.55 lbs./square foot
  • 2" - 3.50 lbs./square foot

R-Value

  • 1.75 per inch of thickness

Tolerances
Tectum ceiling and wall panel measurements are plus or minus 1/8 - 1/4". Thicknesses are nominal. Panels that are to be butted must be beveled and will require field fitting or molding can be used to cover edges.

Limitations
Tectum Acoustical Panels can be used over swimming pools and in open construction such as breezeways and open garages. They should not be installed where they will come in direct contact with water or condensation. Reveal edge panels (Tonico) should not be used for this purpose.

1" panels should not be used where the relative humidity will exceed 85%. Panels 1½" or thicker are not restricted by humidity conditions.

In all cases, the plenum must provide cross-ventilation to prevent condensation.

Fabri-Tough II Wall Panel (1 inch)

Fabri-Tough II Wall Panel attached to studs (1 inch)

Fabri-Tough II Wall Panel attached to CMU (1 inch)

Tectum Inc.
P. O. Box 3002
Newark, OH 43058
Tel: (740) 345-9691
Fax: (800) 832-8869
Tollfree: (888) 977-9691
E-mail: info@tectum.com
Web site: http://www.tectum.com





Sweets app for Revit – Learn More