Stoebich Fire Protection -Smoke Curtain T

DOWNLOADS

Efficient smoke protection curtain at high pressure levels and smoke temperatures up to 392 °F: The Stoebich Smoke Curtain T smoke protection curtain offers reliable protection against smoke penetration and satisfies the requirements defined for smoke protection closures acc.


Category: fire-rated smoke curtains | smoke containment | smoke containment barriers...

MasterFormat: Smoke Containment Barriers



Stoebich Fire Protection
1941 Savage Road
Suite 200B
Charleston, SC 29407
Tel: (843) 203-4999

info@stoebich.us

https://www.stoebich.com/us/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Smoke Curtain T

Efficient smoke protection curtain at high pressure levels and smoke temperatures up to 392 °F: The Stoebich Smoke Curtain T smoke protection curtain offers reliable protection against smoke penetration and satisfies the requirements defined for smoke protection closures acc. to DIN 18095-1. The system is approved up to a size of 23' x 14.8' - larger dimensions are technical feasible and can be realised on request. The Stoebich Smoke Curtain T can securely seal uneven floors by means of its elastic closure strip. In combination with other compensation measures and the use of fire protection fabric, additional protection goals can be realised. The curtain is closed without power using the force of gravity. In accordance with fire tests the Stoebich Smoke Curtain T smoke protection curtain (if the correct fabric is used) can withstand the effects of the fire for more than 90 minutes and also reduces the radiation heat.

  • construction type - textile smoke protection curtain
  • smoke tightness - RS (smoke-tight and self-closing)
  • fire resistant - 2 hours fire rating according to EN 1634-1
  • fabric - Stoebich Fire & Smoke Fabric E 1100 SA2 • Stoebich Fire & Smoke Fabric P 600 2S A2 • Stoebich Fire & Smoke Fabric H
  • closing direction - from top to bottom
  • proof - UB III/B-08-016 (EI 120) • UB III/B-08-012 (EW 90) • UB III/B-06-15 (EW 30) • UB III/B-06-15 (E 120) • DIN 18095-3 • Z-6.62-2264
  • closing cycle - C self-closing • 10,000 cycles (drive unit)

  • See More


    Specifications

    Fabric

    System width

    Unrolled length t

    t (mm)

    h (mm)

    Note

    Stoebich Fire & Smoke Fabric P / E

    < 32.8'

    ≤ 19.7'

    13.78''

    10.24''

    Stoebich Fire & Smoke Fabric P / E

    < 16.4'

    ≤ 14.8'

    11.22'

    7.87''

    Stoebich Fire & Smoke Fabric P / E

    < 11.5'

    ≤ 11.5'

    7.48''

    11.41''

    Stoebich Fire & Smoke Fabric P / E

    < 23'

    ≤ 16.4'

    11.41''

    14.17''

    Stoebich Fire & Smoke Fabric E

    < 23'

    ≤ 10.5'

    13.78''

    10.24''

    Stoebich Fire & Smoke Fabric E

    < 16.4'

    ≤ 8.2'

    11.22'

    7.87''

    Only
    for ceiling-
    mounting

    Stoebich Fire & Smoke Fabric E

    < 11.5'

    ≤ 6.6'

    7.48''

    11.41''

    Stoebich Fire & Smoke Fabric E

    < 19.7'

    ≤ 9.8'

    11.41''

    14.17''

    Sweetsstakes