SAFTI FIRST - SuperLite II-XLM 60 - 60 Minute Fire Resistive Multilaminate Glazing

DOWNLOADS

Features Fire resistive multilamintate glazing offering maximum fire and safety with hose stream for 60 minute wall and door applications. Meets ASTM E-119 for full radiant heat protection and CPSC Cat. II (400 ft. lbs.) impact safety requirements. Can be used in inte


Category: fire-rated glazing | insulated glass | insulating glass...

MasterFormat: Entrances and Storefronts | Glazing | Glass Glazing...



SAFTI FIRST
100 N Hill Drive
Suite 12
Brisbane, CA 94005
Tel: (888) 653-3333
Fax: (415) 824-5900

info@safti.com

http://www.safti.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


SuperLite II-XLM 60 - 60 Minute Fire Resistive Multilaminate Glazing

Features

  • Fire resistive multilamintate glazing offering maximum fire and safety with hose stream for 60 minute wall and door applications.
  • Meets ASTM E-119 for full radiant heat protection and CPSC Cat. II (400 ft. lbs.) impact safety requirements.
  • Can be used in interior and exterior applications, including clear butt-glazed walls for maximum vision and transparency.
  • Optically clear glazing without wires or tints.
  • Available in custom architectural make-ups including energy-saving insulated units, decorative, security and more.
  • Can be easily incorporated in GPX Architectural Series Framing, GPX SNAPCAP or GPX Builders Series Temperature Rise Framing for a complete fire rated assembly.
  • 5 year manufacturer’s warranty.
  • Fabricated in the U.S.A. for fast lead times.
Specifications
  • Thickness:1 in (25 mm) standard
  • Weight:12.3 lbs./sq.ft. (60 kg/m²) In 1 In. (25 mm) standard
  • Sound Reduction:Rw = 42 dB
  • Fire Rating:60 minutes with hose stream. Meets ASTM E119 and NFPA 251
  • Impact Safety Rating:CPSC 16 CFR 1201 Cat. I and II, ANSI Z97.1
  • Light Transmission:81%
  • R-value:1.14
  • U-value:0.881
Listings and warranty

SuperLite II-XLM is listed and labeled by Intertek and Underwriters Laboratories, nationally recognized testing laboratories approved by OSHA.

Standards

UL 9, UL 10B, UL 10C, UL 263, NFPA 80, NFPA 251, NFPA 252, NFPA 257, ASTM E119, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01, CPSC 16 CFR 1201 Cat. Il, ANSI Z97.1, ULC CAN4-S101, ULC CAN4-S104, ULC CAN4-S106.


See More


Specifications

Fire Rating Application Max CV Area Max CV W Max CV H Stops
60 minute Doors 3,855 in.² (2.49 m²) 87-5/8 in. (2.23 m) 87-5/8 in. (2.23 m) 5/8 in. (16 mm)
60 minute Walls (with framing & butt-glazed) 3,855 in.² (2.49 m²) 87-5/8 in. (2.23 m) 87-5/8 in. (2.23 m) 1 in. (25.4 mm)
Sweets app for Revit – Learn More