SAFTI FIRST -SuperLite II-XL 60 60 Minute Fire Resistive Glazing

DOWNLOADS

Features Maximum fire and impact safety with hose stream and full radiant heat protection. Largest tested and approved sizes up to 4,952 sq. in. for door applications in standard 1-1/8” profile. Fully tested, approved and listed for temperature-rise doors, openings and wall applications. Tint-


Category: fire-rated glazing | insulated glass | sound control glazing...

MasterFormat: Doors and Frames | Door Louvers and Vision Lights | Fire-Rated Glass and Glazing Systems...



SAFTI FIRST
100 N Hill Drive
Suite 12
Brisbane, CA 94005
Tel: (888) 653-3333
Fax: (415) 824-5900

info@safti.com

http://www.safti.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


SuperLite II-XL 60 60 Minute Fire Resistive Glazing


Features

  • Maximum fire and impact safety with hose stream and full radiant heat protection.
  • Largest tested and approved sizes up to 4,952 sq. in. for door applications in standard 1-1/8” profile.
  • Fully tested, approved and listed for temperature-rise doors, openings and wall applications.
  • Tint-free and optically clear. Perfect for property line requirements.
  • Acoustical value of 42 STC.
  • Available in any custom architectural make-up, such as laminated glass and energy-saving insulated units with NFRC certifications when used with GPX Architectural Series Framing.
  • USA manufactured for fast delivery and competitive pricing.
  • Thin 7/8” profile is available up to 1,296 sq. in.
Specifications
  • Thickness: 1-1/8” (29mm) standard and 7/8” (23mm) thin profile
  • Weight: 9 lbs./sq. ft. in 1-1/8” (29mm) standard profile
  • Sound Transmission Rating: STC 42 rating in 1-1/8” (29mm) standard profile
  • Outdoor-Indoor Transmission Class: OITC 39 rating in 1-1/8” (29mm) standard profile
  • Fire Rating: 60 minutes with hose stream Meets ASTM E119 and NFPA 251
  • Impact Safety Rating: CPSC 16 CFR 1201 Cat. I and II
  • NFRC Certifications with GPX Framing:
    0.39 U-Factor when insulated with Solarban 60
    0.31 SHGC when insulated with Solarban 60
    57 Condensation Resistance when insulated with Solarban 60
Listings and warranty

SuperLite II-XL is listed and labeled by Intertek/Warnock-Hersey Inc. and Underwriters Laboratories, nationally recognized testing laboratories approved by OSHA.


Standards

UL 9, UL 10B, UL 10C, UL 263, NFPA 80, NFPA 251, NFPA 252, NFPA 257, ASTM E119, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01, CPSC 16 CFR 1201 Cat. II., ULC CAN4-S101, ULC CAN4-S104, ULC CAN4-S106, NFRC 100, NFRC 200, NFRC 500.


See More


Specifications

Fire RatingApplicationMax CV AreaMax CV WMax CV HStops
60 min.All 60 Minute Applications4,952 in²124"124"5/8"