Rapid Floor® Systems - Maxxon® DPM (Damp Proof Membrane)

Maxxon ® DPM (Damp Proof Membrane) is a unique 2-component, moisture tolerant, extremely high density, chemically enhanced epoxy based product which prevents the passage of water vapor and moisture through slabs or walls on or below grade, thus eliminating delamination of adhesives, floor...


Category: water proofing

MasterFormat: Sheathing | Underlayment | Dampproofing...



Rapid Floor® Systems
920 Hamel Road
P.O. Box 253
Hamel, MN 55340
Tel: (800) 356-6720
Fax: (763) 478-9695

info@rapidfloor.com

http://www.rapidfloor.com

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview



Maxxon® DPM (Damp Proof Membrane)

Maxxon® DPM (Damp Proof Membrane)

Maxxon® DPM (Damp Proof Membrane) is a unique 2-component, moisture tolerant, extremely high density, chemically enhanced epoxy based product which prevents the passage of water vapor and moisture through slabs or walls on or below grade, thus eliminating delamination of adhesives, floor coverings and coatings. It also prevents capillary infiltration of oil or other chemicals from the ground and can be used to treat oil contaminated slabs.

  • Reduces moisture vapor emission
  • 1-coat application
  • Underlayment system installed next day
  • Applied to moist or dry concrete
  • High alkalinity barrier


Maxxon® DPM Technical Data Sheet


Material
2-component epoxy
Color
White
Density
15.49 lbs/gal (1.86 kg/L)
VOC Content, mixed
.5 lbs/gal (55 g/L)
Flash Point
                                Part A:
                                Part B:

>212°F (>100° C)
170°F (77° C)
Volume Solids
97%

Pot Life, approx
60 Minutes at 75°F (24° C)
30 Minutes at 85°F (30° C)
Open to Foot Traffic
after 12 hrs at 73°F (23° C)
Curing Temperature
minimum 46°F (8° C)
Full Strength
after 7 days
Compressive Strength
(ASTM D-695)
>11,000 psi (>80 MPa)
Flexural Strength
(ASTM D-790)
>4,300 psi (>30 MPa)
Adhesion to:
                            -new concrete (5 days):
                             -moist concrete (28 d):
                            -dry concrete (28 d):
(ASTM D-4541)

110 psi (0.8 MPa)
550 psi (3.8 MPa)
580 psi (4.0 MPa)
Temperature Resistance
                                Continuous:
                                -dry heat:
                                -humid:
                                Intermittent:
                         -high pressure water:

                                -dry heat:


140° F (60° C)
113° F (45° C)

185° F (85° C)
248° F briefly (120° C)
149-185° F (65-68° C)
All data are average values obtained under laboratory conditions.
In practical use temperatures, humidity and absorbance of the substrate may influence the above given values.

Rapid Floor® Systems
920 Hamel Road
P. O. Box 253
Hamel, MN 55340
Tel: (763) 478-9655
Fax: (763) 478-9695
Tollfree: (800) 356-6720
E-mail: info@rapidfloor.com
Web site: http://www.rapidfloor.com





Sweets app for Revit – Learn More