ROCKFON -Chicago Metallic® 4000 Tempra™ 9/16" Ceiling Grid

DOWNLOADS

Chicago Metallic® 4000 Tempra™ 9/16" Exposed grid ceiling system is available in both intermediate and heavy-duty designs, both non-fire rated and fire rated construction, and is built with HDG 30 steel.


Category: ceiling suspension systems | dropped ceilings | exposed grid ceilings...

MasterFormat: Ceilings | Acoustical Ceiling Suspension Assemblies



ROCKFON
4849 S. Austin Ave
Chicago, IL 60638
Tel: (800) 323-7164
Fax: (800) 222-3744

cs@rockfon.com

https://www.rockfon.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Chicago Metallic® 4000 Tempra™ 9/16" Ceiling Grid

Chicago Metallic® 4000 Tempra™ 9/16" Exposed grid ceiling system is available in both intermediate and heavy-duty designs, both non-fire rated and fire rated construction, and is built with HDG 30 steel.This drop ceiling grid features both seismically approved stab-end cross tees and demountable hook-end cross tees. Chicago Metallic™ grid systems are third party certified to meet ASTM standards and are listed with ICCES Evaluation Services, see report ESR-2631 for more information.

Performance Properties:
-Grid system is available in both intermediate and heavy duty designs, with either stab-end and hook-end cross tees
-Fire rated components are designed with expansion reliefs, making it suitable for fire-rated ceiling assemblies
-Suspension system in (4000) non-fire rated, (4050) fire rated, and in (4000HRC) high recycled content
-Sustainable: Minimum 25% recycled content,100% locally recyclable
-Chicago Metallic® suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E1264-08

Available in the following standard colors, Rockfon® Color-all™ colors, and RAL color options.

Material

ASTM C 635 Heavy Duty (HD) and Intermediate Duty (ID) main tee classifications; commercial quality steel, G30 hot-dip galvanized body and cap, 9/16" width, 1-1/2" and 1-5/8" heights.

Note: A metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed.

Application Areas

Hospitals, hospitality, retail, airports, transit, galleries, and offices.


See More


Specifications

Grid Colors

01 White

08 Black

44 Satin Silver

Color-all

RAL

Component Load Test Data and Material
Main TeeLengthAllowable Load per ASTM C635
Hanger Spacing
4'5'6'
4000144"ID6.43.8
4040144"HD8.85.3
4040 HRC144"HD8.8
4050144"ID
Cross TeeLength2'3'4'5'
402224"24.5 ▲
4022 HRC24"24.5 ▲
403224"24.5 ▲
405224"45.0 ▲
401448"12.9
4014 HRC48"12.9
403448"12.9
405448"12.9
401560"6.5
401772"27.3 •▲
401896"12.5 •▲

To convert data into lb/ft2, divide on center spacing of component into lb/ft.
▲ Limited by safety factor of 2.
• Wire at mid-point of member
Note: For 6’ and 8’ cross tee spans with no hanger support at mid-point of member, please contact Technical Ser

Light Fixture Load Test Data (based on 1/360 span deflection)
DimensionsLight Fixtures
Main & Cross Tees - Allowable Fixture Weight - Pounds
4040CH 4014CZ4040CH 4014HRCZ4000CZ 4015CH4001CH 4015CH4050.01CH 4054.01CH
1’ x 4’42.442.445.6
2’ x 2’38.838.838.8
2’ x 4’49.649.644.0 ▲49.6
20” x 48”35.035.0
20” x 60”35.035.0

▲ Limited by safety factor of 2.

Product Performance
Fire Rated Assemblies Hanger Positions for Fire Rated Situations
This illustrates hanger positions for single fixtures in a field and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area.
Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations
This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures.
Environment Materials and Resources (MR)
-Waste Management Planning
-Interiors Life Cycle Impact Reduction
-Environmental Product Declarations
-Sourcing of Raw Materials
-Material Ingredients
-Waste Management
Indoor Environmental Quality (EQ)
-Low-Emitting Materials
-Interior Lighting
-Acoustic Performance
Accessories
Compatible Tile Edge Types

4000/4050/4000HRC Systems
Main Runners RFN-NA
ComponentLengthHeightFace WidthSlot SpacingFire RatedSeismicRecycled Content PercentageSlotting ClassDutyHDG CoatingHRC
144"1-5/8"9/16"6" OCC, DEF25%6" OC, HDHDG30
120"1-5/8"9/16"10" OCC25%10" OC, IDIDG30
144"1-5/8"9/16"6" OCC25%6" OC, IDIDG30
144"1-5/8"9/16"6" OCFire RatedC25%6" OC, IDIDG30
144"1-5/8"9/16"Slots 6" OCC, DEF65%Slots 6" OC, HDHDG30HRC
Cross Tees RFN-NA
ComponentLengthHeightFace WidthSlot SpacingFire RatedSeismicRecycled Content PercentageSlotting ClassGrid Coupling TypeHDG CoatingHRC
4"1-1/2"9/16"No SlotsC, DEF25%No SlotsStab-EndG30
20"1-1/2"9/16"No SlotsC, DEF25%No SlotsStab-EndG30
48"1-1/2"9/16"24" OCC25%24" OCHook-EndG30
6"1-1/2"9/16"No SlotsC, DEF25%No SlotsStab-EndG30
96"1-1/2"9/16"12" OCC, DEF25%12" OCStab-EndG30
72"1-1/2"9/16"12" OCC, DEF25%12" OCStab-EndG30
24"1-1/2"9/16"No SlotsC, DEF25%No SlotsStab-EndG30
48"1-1/2"9/16"12" OCC, DEF25%12" OCStab-EndG30
60"1-1/2"9/16"10" OCC, DEF25%10" OCStab-EndG30
24"1-1/2"9/16"No SlotsC25%No SlotsHook-EndG30
48"1-3/4"9/16"12" OCFire RatedC, DEF25%12" OCStab-EndG30
24"1-3/4"9/16"No SlotsFire RatedC, DEF25%No SlotsStab-EndG30
48"1-5/8"9/16"Slots 12" OCC, DEF65%Slots 12" OCStab-EndG30HRC
24"1-5/8"9/16"No SlotsC, DEF65%No SlotsStab-EndG30HRC
Wall Angles RFN-NA
ComponentLengthHeightFace WidthSeismicRecycled Content PercentageHRC
144"15/16"15/16"C, DEF25%
144"15/16"15/16"C, DEF25%
144"9/16"15/16"C, DEF25%
144"15/16"15/16"C, DEF65%HRC
144"9/16"15/16"C, DEF65%HRC
Shadow Moldings RFN-NA
ComponentLengthHeightFace WidthSeismicRecycled Content PercentageSlotting Class
120"3/4"3/4"C25%3/8" Reveal
120"3/4"3/4"C25%3/4" Reveal
120"15/16"9/16"C25%3/8" Reveal

Note: Cross tees are override design, with stab-in end detail, unless noted otherwise. Hook end tees are suitable for seismic areas 1 and 2 only. Butt-cut tees are used for true, flat panel installation, i.e., metal panels. Wires required at mid point for loads exceeding weight of Rockfon tile.