Why Use PRO Hydronic’s CBV?

Following the PRO Hydronic Specialties’ philosophy of “physics first” designs, our full line of manual balancing venturis are some of the most efficient and easy to commission manual balancing devices in the industry


Category: balancing valves | fittings | piping systems...

MasterFormat: Operation and Maintenance of Plumbing | Common Work Results for Plumbing | Plumbing Piping...



PRO Hydronic Specialties
801 State Highway 64W
Henderson, TX 75652
Tel: (903) 722-9114
Fax: (903) 722-9120

info@prohydronic.com

http://www.prohydronicspecialties.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Manual Balancing

Why Use PRO Hydronic’s CBV?

Following the PRO Hydronic Specialties’ philosophy of “physics first” designs, our full line of manual balancing venturis are some of the most efficient and easy to commission manual balancing devices in the industry. Our designs incorporate features such as proper regain angle and length for low energy loss. Additionally, we have integrated the proper upstream pipe diameters needed for smooth flow and optimal accuracy.

Features and Benefits

  • Extremely low energy loss

  • Flow measurement inherent to design

  • +/- 3% accuracy rate

  • Memory stop included

  • Available in MPT, FPT, and SWT connections

  • Includes (2) ¼” Pressure/Temperature Ports

  • Factory calculated In. W.C. printed on each tag for quick and easy commissioning

  • Forged construction for:

    • Tight tolerances

    • Impeccable Accuracy

    • Smooth, laminar flow

Applications
  • Air Handlers

  • Fan Coil Units

  • Chilled Beams

  • Cooling Towers

  • Water Source Heat Pumps

  • Chillers

  • VAV HW Coils

  • Unit Ventilators

  • Hydronic Heaters

  • Devices shall have a 15° regain chamber for optimal pressure regain and minimal permanent pressure drop

  • The Venturi tube shall be independent of the throttling valve

  • The Venturi tube shall include proper pipe diameters for optimal accuracy

  • The valve shall be designed with a memory stop to limit flow once balanced

  • The Model CBV shall have an accuracy rating of:

  • +/- 1% between 10” W.C. and 70” W.C.

  • +/- 3% between 5” W.C. and 150” W.C.

  • +/- 5% less than 5” W.C. and over 150” W.C.

Why a Venturi with ¼” Turn Valve?

Strainer Effect on Low Flow Manual Balancing Valves

The following illustration will help demonstrate that orifice sizes are often very small for low flow balancing valves. The physical configuration of the gap from the globe or disk design is smaller than the strainer mesh opening for low flow requirements. PRO Hydronics utilizes a ¼” turn valve which allows for optimal orifice size for a manual balancing valve under low flow conditions.

When the orifice gap becomes smaller than the opening of the strainer mesh, clogging is imminent.

How easy is it to limit flow? Easy as 1,2,3!

No calculator wheels or guessing required!

  • Determine the differential pressure in Inches W.C. (pre-printed on tag, Flow Rate Table, or by equation).

  • Attach a differential pressure gauge.

  • Close the valve until the desired differential is achieved.

    • Set the memory stop to limit full open if preferred.


See More


Specifications

The Pro Hydronic’s Advantage
Type of OrificeAdvantagesDisadvantages
Calibrated Variable Orifice
  • Inexpensive
  • Extremely poor flow
  • Estimation of flow, not true measurement
  • Tendency to clog
Orifice Plate
  • Inexpensive
  • High permanent pressure loss
  • Less range of flow signal per throat beta
Truncated Venturi
  • Inexpensive
  • High permanent pressure loss
  • Sensitive to upstream pressure disruptions
  • Loss of accuracy
PRO Hydronic’s True Venturi
  • Lowest pressure loss
  • Optimized 15° pressure regain chamber
  • Wide range of flow signal per throat beta
  • Opportunity for selection of proper
    pressure signal
  • Naturally longer to allow for proper regain
  • Slightly more expensive than other de-featured designs