On-Q® - 3-Way Digital Cable Splitter w/ Coax Network Support

DOWNLOADS

VM2203-V1 On-Q This professional-grade digital cable splitter distributes HDTV Antenna/Digital Cable and coax data network signals to three devices. Ideal for MoCA-capable networks. Exceeds the performance standards set by major cable providers Compatible with existing and future networks such as Mo


Category: coaxial cable distribution systems | communications hardware | data network equipment...

MasterFormat: Data Communications | Data Communications Network Equipment | Audio-Video Communications...



On-Q®
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Tel: (800) 223-4162
Fax: (800) 223-4196

customer.support.lv@legrand.us

http://www.legrand.us/onq.aspx

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


3-Way Digital Cable Splitter w/ Coax Network Support

VM2203-V1 On-Q

This professional-grade digital cable splitter distributes HDTV Antenna/Digital Cable and coax data network signals to three devices. Ideal for MoCA-capable networks.

  • Exceeds the performance standards set by major cable providers
  • Compatible with existing and future networks such as MoCA, VoIP, and DOCSIS 3.0
  • 6kV Surge Protection on all ports
  • Coax networking adapters and splitters are not compatible with satellite television systems


See More


Specifications

Specifications
General Info Cable Type: Coaxial
Color: Black
Connection Type: ANSI/SCTE 01 Compliant ECT F-port
Type: Signal Splitter
Surge Protected: 6 kV ring wave surges per IEEE specification C62.41 Category A3
Listing Agencies/Third Party Certifications UN SPSC: 32101529
Dimensions Depth (Metric): 15.3 mm
Depth (US): 0.60"
Length (Metric): 84.9 mm
Length (US): 3.3"
Width (Metric): 45.1 mm
Width (US): 1.8 in
Technical Information Frequency: 5 MHz - 1525 MHz
OhmValue: 75 Ohm Nominal impedance
Operating Temperature (Celsius): -40°C to 60°C
Supported Standards: Exceeds ANSI/SCTE 143 specifications for corrosion, 1000 hours
Typical Insertion Loss: Freq(MHz) Typical(dB)
5 - 40 3.4/ 6.8
41 - 200 3.6/ 7.1
201 - 550 3.8/ 7.4
551 - 750 4.0/ 7.8
751 - 1002 4.0/ 8.0
1125 - 1325 7.5/13.0
1326 - 1525 10.5/18.0 Typical Return Loss: Input:
Freq(MHz) Typical
5 - 14 25 dB
15 - 40 28 dB
41 - 200 26 dB
201 - 1002 22 dB
Output:
Freq(MHz) Typical
5 - 14 25 dB
15 - 40 38 dB
41 - 200 30 dB
201 - 1002 22 dB
Sweets app for Revit – Learn More