Mitsubishi Electric HVAC-Proposed - SLZ-KA/SUZ-KA - M-Series Heat Pump Systems-0_SLZ-KA15NA

SLZ-KA/SUZ-KA - M-Series Heat Pump Systems Model Number: 0_SLZ-KA15NA Ceiling-recessed cassette (24"x24") ductless heat pump units offer a wide airflow pattern for better air distribution in a less obtrusive style.  Intall SLZ in a hard ceiling (with an access panel for servicing) or in a 2'x2'...


MasterFormat: Central HVAC Equipment | Decentralized Unitary HVAC Equipment | Air-Source Unitary Heat Pumps...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



SLZ-KA/SUZ-KA - M-Series Heat Pump Systems - 0_SLZ-KA15NA

SLZ-KA/SUZ-KA - M-Series Heat Pump Systems


Model Number: 0_SLZ-KA15NA

Ceiling-recessed cassette (24"x24") ductless heat pump units offer a wide airflow pattern for better air distribution in a less obtrusive style.  Intall SLZ in a hard ceiling (with an access panel for servicing) or in a 2'x2' drop ceiling. Rated capacities range from 8,400 to 15,000 Btu/h.


Wide airflow pattern for excellent air distribution
4" ventilation air intake knockout
Built-in drain condensate lift mechanism
Select from MHK1 (preferred), PAR-21MA, or PAR-FL/FA32 remote controllers
Long-life air filter included
Automatic fan speed control
Limited warranty: five years on parts and defects and seven years on compressors




Power Supply Phase, Cycle, Voltage 2 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 8400 Btu/h (2.46 kW) *1
Cooling Capacity Range 3,100-10,900 Btu/h (0.9 - 3.2 kW)
Cooling Total Input 700 W (0.700 kW)
Cooling Energy Efficiency SEER 15
Cooling Sensible Heat Factor 0.84
Cooling Moisture Removal Pints/H 1.2
Cooling EER 12
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 3,100-14,100 Btu/h (0.9 - 4.1 kW)
Heating at 47° F Total Input 930 W
Heating at 47° F HSPF (Region IV) 9.6
Heating at 47° F COP 3.44 Btu/Btu
Heating at 17° F Maximum Capacity 6200 Btu/h (1.8 kW)
Heating at 17° F COP 2.46 Btu/Btu
Heating at 17° F Rated Capacity 13101 Btu/h (3.8 kW) *3
Heating at 17° F Total Input 1351 W
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Compressor Model KNB073FQDHC
Fan Fan Motor - F.L.A. 0.23 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 280-320-350 CFM (8-9-10 m³/min) *1
Airflow Cooling : WET 250-290-320 CFM (7-8-9 m³/min) *1
Airflow Heating : WET 250-290-320 CFM (7-8-9 m³/min) *2
Sound Pressure Level 29-32-38 dB(A)
Dimensions H x W x D Height UNIT : 9-1/4 Inches (235 mm) ; Grille 13/16 Inches (20 mm)
Dimensions H x W x D Width Unit: 22-7/16 Inches (570 mm) ; Grille: 25-5/8 Inches (650 mm)
Dimensions H x W x D Depth Unit: 22-7/16 Inches (570 mm) ; Grille: 25-5/8 Inches (650 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
External Finish Unit: Galvanized sheets with gray heat insulation ; Grille: ABS resin Munsell 6.4Y 8.9/0.4
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 3 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 11100 Btu/h (3.25 kW) *1
Cooling Capacity Range 3,400-13,300 Btu/h (1 - 3.9 kW)
Cooling Total Input 920 W (0.900 kW)
Cooling Energy Efficiency SEER 15.4
Cooling Sensible Heat Factor 0.77
Cooling Moisture Removal Pints/H 2.3
Cooling EER 12
Heating at 47° F Rated Capacity 13600 Btu/h (4 kW) *2
Heating at 47° F Capacity Range 3,100-17,100 Btu/h (0.9 - 5 kW)
Heating at 47° F Total Input 1180 W
Heating at 47° F HSPF (Region IV) 9.6
Heating at 47° F COP 3.38 Btu/Btu
Heating at 17° F Maximum Capacity 8300 Btu/h (2.4 kW)
Heating at 17° F COP 2.62 Btu/Btu
Heating at 17° F Rated Capacity 13102 Btu/h (3.8 kW) *3
Heating at 17° F Total Input 1352 W
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.28 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 280-320-390 CFM (8-9-11 m³/min)
Airflow Cooling : WET 250-290-350 CFM (7-8-10 m³/min)
Airflow Heating : WET 250-290-350 CFM (7-8-10 m³/min)
Sound Pressure Level 30-34-39 dB(A)
Dimensions H x W x D Height UNIT : 9-1/4 Inches (235 mm) ; Grille 13/16 Inches (20 mm)
Dimensions H x W x D Width Unit: 22-7/16 Inches (570 mm) ; Grille: 25-5/8 Inches (650 mm)
Dimensions H x W x D Depth Unit: 22-7/16 Inches (570 mm) ; Grille: 25-5/8 Inches (650 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
External Finish Unit: Galvanized sheets with gray heat insulation ; Grille: ABS resin Munsell 6.4Y 8.9/0.4
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 4 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 15000 Btu/h (4.4 kW) *1
Cooling Capacity Range 3,800-17,700 Btu/h (1.1 - 5.2 kW)
Cooling Total Input 1460 W (1.500 kW)
Cooling Energy Efficiency SEER 16
Cooling Sensible Heat Factor 0.67
Cooling Moisture Removal Pints/H 4.5
Cooling EER 10.2
Heating at 47° F Rated Capacity 18000 Btu/h (5.3 kW) *2
Heating at 47° F Capacity Range 3,100-22,000 Btu/h (0.9 - 6.5 kW)
Heating at 47° F Total Input 1950 W
Heating at 47° F HSPF (Region IV) 9.6
Heating at 47° F COP 2.7 Btu/Btu
Heating at 17° F Maximum Capacity 12000 Btu/h (3.5 kW)
Heating at 17° F COP 2.38 Btu/Btu
Heating at 17° F Rated Capacity 13103 Btu/h (3.8 kW) *3
Heating at 17° F Total Input 1353 W
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.28 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 280-320-390 CFM (8-9-11 m³/min)
Airflow Cooling : WET 250-290-350 CFM (7-8-10 m³/min)
Airflow Heating : WET 250-290-350 CFM (7-8-10 m³/min)
Sound Pressure Level 31-35-40 dB(A)
Dimensions H x W x D Height UNIT : 9-1/4 Inches (235 mm) ; Grille 13/16 Inches (20 mm)
Dimensions H x W x D Width Unit: 22-7/16 Inches (570 mm) ; Grille: 25-5/8 Inches (650 mm)
Dimensions H x W x D Depth Unit: 22-7/16 Inches (570 mm) ; Grille: 25-5/8 Inches (650 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m)
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit - Inches (Meter) 33 ft. (10 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Unit: Galvanized sheets with gray heat insulation ; Grille: ABS resin Munsell 6.4Y 8.9/0.4
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Energy Star System X
Power Supply Phase, Cycle, Voltage 2 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 8400 Btu/h (2.46 kW) *1
Cooling Capacity Range 3,100-10,900 BTU/h (0.9 - 3.2 kW)
Cooling Total Input 700 W (0.700 kW)
Cooling Energy Efficiency SEER 15
Cooling Sensible Heat Factor 0.84
Cooling EER 12
Cooling Moisture Removal Pints/H 1.2
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 3,100-14,100 Btu/h (0.9 - 4.1 kW)
Heating at 47° F Total Input 930 W
Heating at 47° F HSPF (Region IV) 9.6
Heating at 47° F COP 3.44 Btu/Btu
Heating at 17° F Maximum Capacity 6200 Btu/h (1.8 kW)
Heating at 17° F COP 2.46 Btu/Btu
Heating at 17° F Rated Capacity 13101 Btu/h (3.8 kW) *3
Heating at 17° F Total Input 1351 W
Minimum Circuit Ampacity MCA 12 Ampere
Maximum fuse size (time delay) MOCP 12 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Oil Type NE022 (10.8)
Refrigerant Type R410A
Refrigerant Charge 2
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven
Compressor Model KNB073FQDHC
Compressor R.L.A. 6.6
Compressor L.R.A. 8.2
Fan Fan Motor - F.L.A. 0.5 F.L.A
Airflow Cooling 1151 CFM (33 m³/min)
Airflow Heating 1225 CFM (35 m³/min)
Sound Pressure Level Heating 50 dB(A)
Sound Pressure Level Cooling 46 dB(A)
Dimensions H x W x D Height 21-5/8 Inches (550 mm)
Dimensions H x W x D Width 31-1/2 Inches (800 mm)
Dimensions H x W x D Depth 11-1/4 Inches (285 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Height Difference 40 ft. (12 m)
Maximum Refrigerant Pipe Length 65 ft. (19 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Munsell 3Y 7.8/1.1
Defrost Method Reverse Cycle
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Energy Star System X
Power Supply Phase, Cycle, Voltage 3 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 11100 Btu/h (3.25 kW) *1
Cooling Capacity Range 3,400-13,300 BTU/h (1 - 3.9 kW)
Cooling Total Input 920 W (0.900 kW)
Cooling Energy Efficiency SEER 15.4
Cooling Sensible Heat Factor 0.77
Cooling Moisture Removal Pints/H 2.3
Cooling EER 12
Heating at 47° F Rated Capacity 13600 Btu/h (4 kW) *2
Heating at 47° F Capacity Range 3,100-17,100 Btu/h (0.9 - 5 kW)
Heating at 47° F Total Input 1180 W
Heating at 47° F HSPF (Region IV) 9.6
Heating at 47° F COP 3.38 Btu/Btu
Heating at 17° F Maximum Capacity 8300 Btu/h (2.4 kW)
Heating at 17° F COP 2.62 Btu/Btu
Heating at 17° F Total Input 1352 W
Heating at 17° F Rated Capacity 13102 Btu/h (3.8 kW) *3
Minimum Circuit Ampacity MCA 12 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NE022 (10.8)
Refrigerant Charge 2, 9
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven
Compressor Model KNB092FQAHC
Compressor L.R.A. 8.2
Compressor R.L.A. 6.6
Fan Fan Motor - F.L.A. 0.5 F.L.A
Airflow Cooling 1229 CFM (35 m³/min)
Airflow Heating 1172 CFM (33 m³/min)
Sound Pressure Level Cooling 49 dB(A)
Sound Pressure Level Heating 51 dB(A)
Dimensions H x W x D Height 21-5/8 Inches (550 mm)
Dimensions H x W x D Width 31-1/2 Inches (800 mm)
Dimensions H x W x D Depth 11-1/4 Inches (285 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Height Difference 40 ft. (12 m)
Maximum Refrigerant Pipe Length 65 ft. (19 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Defrost Method Reverse Cycle
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Munsell 3Y 7.8/1.1

Power Supply Phase, Cycle, Voltage 4 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 15000 Btu/h (4.4 kW) *1
Cooling Capacity Range 3,800-17,700 BTU/h (1.1 - 5.2 kW)
Cooling Total Input 1460 W (1.500 kW)
Cooling Energy Efficiency SEER 16
Cooling Sensible Heat Factor 0.67
Cooling EER 10.2
Cooling Moisture Removal Pints/H 4.5
Heating at 47° F Rated Capacity 18000 Btu/h (5.3 kW) *2
Heating at 47° F Capacity Range 3,100-22,000 Btu/h (0.9 - 6.4 kW)
Heating at 47° F Total Input 1950 W
Heating at 47° F HSPF (Region IV) 9.6
Heating at 47° F COP 2.7 Btu/Btu
Heating at 17° F Maximum Capacity 12000 Btu/h (3.5 kW)
Heating at 17° F COP 2.38 Btu/Btu
Heating at 17° F Rated Capacity 13103 Btu/h (3.8 kW) *3
Heating at 17° F Total Input 1353 W
Minimum Circuit Ampacity MCA 12 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NEO22 (15.2)
Refrigerant Charge 2, 9
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model SNB130FQBH
Compressor R.L.A. 7.4
Compressor L.R.A. 9.3
Fan Fan Motor - F.L.A. 0.5 F.L.A
Airflow Cooling 1243 CFM (35 m³/min)
Airflow Heating 1229 CFM (35 m³/min)
Sound Pressure Level Heating 51 dB(A)
Sound Pressure Level Cooling 49 dB(A)
Dimensions H x W x D Height 21-5/8 Inches (550 mm)
Dimensions H x W x D Width 31-1/2 Inches (800 mm)
Dimensions H x W x D Depth 11-1/4 Inches (285 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Height Difference 40 ft. (12 m)
Maximum Refrigerant Pipe Length 65 ft. (19 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Defrost Method Reverse Cycle

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com

Sweets app for Revit – Learn More