Mitsubishi Electric HVAC-Proposed - SEZ - M-Series Heat Pumps - Indoor Units (Multi Zone)-0_SEZ-KD18NA4

SEZ - M-Series Heat Pumps - Indoor Units (Multi Zone) Model Number: 0_SEZ-KD18NA4 Concealed horizontal ducted unit for applications with short duct runs.  SEZ units provide comfort and efficiency while staying hidden either in the ceiling or beneath the floor. Rated capacities range from...


MasterFormat: Central HVAC Equipment | Decentralized Unitary HVAC Equipment | Air-Source Unitary Heat Pumps...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



SEZ - M-Series Heat Pumps - Indoor Units (Multi Zone) - 0_SEZ-KD18NA4

SEZ - M-Series Heat Pumps - Indoor Units (Multi Zone)


Model Number: 0_SEZ-KD18NA4

Concealed horizontal ducted unit for applications with short duct runs.  SEZ units provide comfort and efficiency while staying hidden either in the ceiling or beneath the floor. Rated capacities range from 8,100-17,200 Btu/h.


Quiet operation as low as 23 dBA
Ultra thin body: 7-7/8" high
Built-in drain mechanism for condensate removal; lifts to 21-11/16"
Air filter is included with indoor unit
Automatic fan speed control
PAR-21MAA wired remote controller is included
Indoor unit powered from outdoor unit using A-Control
Automatic fan speed control
Auto restart following a power outage
Limited warranty: five years on parts and defects and seven years on compressors




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 8100 Btu/h (2.37 kW) *1
Cooling Capacity Range 3800 - 10900 BTU/h (1.1 - 3.2 kW)
Cooling Total Input 670 W (0.700 kW)
Cooling Energy Efficiency SEER 15
Cooling Sensible Heat Factor 0.8
Cooling EER 12
Cooling Moisture Removal Pints/H 1.5
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 4800 - 14100 Btu/h (1.4 - 4.1 kW)
Heating at 47° F Total Input 1020 W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.14 Btu/Btu
Heating at 17° F Maximum Capacity 6700 Btu/h (2 kW)
Heating at 17° F COP 2.42 Btu/Btu
Heating at 17° F Rated Capacity 6700 Btu/h (2 kW) *3
Heating at 17° F Total Input 810 W
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.51 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 194-247-317 CFM (5-7-9 m³/min)
Airflow Cooling : WET 174-222-285 CFM (5-6-8 m³/min)
Airflow Heating : WET 174-222-285 CFM (5-6-8 m³/min)
Sound Pressure Level 23-26-30 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 39 Inches (990 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized-Steel Sheets
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 11500 Btu/h (3.37 kW) *1
Cooling Capacity Range 3800 - 13300 BTU/h (1.1 - 3.9 kW)
Cooling Total Input 920 W (0.900 kW)
Cooling Energy Efficiency SEER 16
Cooling Sensible Heat Factor 0.76
Cooling Moisture Removal Pints/H 2.4
Cooling EER 12.5
Heating at 47° F Rated Capacity 13600 Btu/h (4 kW) *2
Heating at 47° F Capacity Range 4800 - 16400 Btu/h (1.4 - 4.8 kW)
Heating at 47° F Total Input 1140 W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.5 Btu/Btu
Heating at 17° F Maximum Capacity 9000 Btu/h (2.6 kW)
Heating at 17° F COP 2.88 Btu/Btu
Heating at 17° F Total Input 920 W
Heating at 17° F Rated Capacity 9000 Btu/h (2.6 kW) *3
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.57 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 247-317-388 CFM (7-9-11 m³/min)
Airflow Cooling : WET 222-285-349 CFM (6-8-10 m³/min)
Airflow Heating : WET 222-285-349 CFM (6-8-10 m³/min)
Sound Pressure Level 23-28-33 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 39 Inches (990 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
External Finish Galvanized-Steel Sheets
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 14100 Btu/h (4.13 kW) *1
Cooling Capacity Range 3800 - 17000 BTU/h (1.1 - 5 kW)
Cooling Total Input 1170 W (1.200 kW)
Cooling Energy Efficiency SEER 15.5
Cooling Sensible Heat Factor 0.8
Cooling Moisture Removal Pints/H 2.6
Cooling EER 12
Heating at 47° F Rated Capacity 18000 Btu/h (5.3 kW) *2
Heating at 47° F Capacity Range 4800 - 21100 Btu/h (1.4 - 6.2 kW)
Heating at 47° F Total Input 1500 W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.52 Btu/Btu *2
Heating at 17° F Maximum Capacity 11900 Btu/h (3.5 kW)
Heating at 17° F COP 2.92 Btu/Btu
Heating at 17° F Rated Capacity 11900 Btu/h (3.5 kW) *3
Heating at 17° F Total Input 1200 W
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.74 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 353-441-529 CFM (10-12-15 m³/min)
Airflow Cooling : WET 317-396-476 CFM (9-11-13 m³/min)
Airflow Heating : WET 317-396-476 CFM (9-11-13 m³/min)
Sound Pressure Level 30-34-37 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 39 Inches (990 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized-Steel Sheets
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 17200 Btu/h (5.04 kW) *1
Cooling Capacity Range 3800 - 19000 BTU/h (1.1 - 5.6 kW)
Cooling Total Input 1380 W (1.400 kW)
Cooling Energy Efficiency SEER 17.5
Cooling Sensible Heat Factor 0.79
Cooling Moisture Removal Pints/H 3.4
Cooling EER 12.5
Heating at 47° F Rated Capacity 21600 Btu/h (6.3 kW) *2
Heating at 47° F Capacity Range 4800 - 24900 Btu/h (1.4 - 7.3 kW)
Heating at 47° F Total Input 1700 W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.72 Btu/Btu
Heating at 17° F Maximum Capacity 13100 Btu/h (3.8 kW)
Heating at 17° F COP 2.84 Btu/Btu
Heating at 17° F Total Input 1350 W
Heating at 17° F Rated Capacity 13100 Btu/h (3.8 kW) *3
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.74 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 423-529-635 CFM (12-15-18 m³/min)
Airflow Cooling : WET 381-476-572 CFM (11-13-16 m³/min)
Airflow Heating : WET 381-476-572 CFM (11-13-16 m³/min)
Sound Pressure Level 30-34-38 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 46-7/8 Inches (1,190 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -4°F (-20°C) DB, -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -5°F (-21°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -4°F (-20°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Galvanized-Steel Sheets