Mitsubishi Electric HVAC-Proposed - PEA/PEAD - P-Series AC-0_PEA-A18AA4/PUY-A18NHA4

PEA/PEAD - P-Series AC Model Number: 0_PEA-A18AA4/PUY-A18NHA4 Ceiling concealed horizontal ducted unit for applications with short duct runs. Rated capacities range from 12,000-42,000 Btu/h. Drain Drain lift for condensate removal (21-11/16" PEA, 27-9/16" PEAD lift) Air filter is included with...


MasterFormat: Central Cooling Equipment | Decentralized HVAC Equipment | Decentralized Unitary HVAC Equipment...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



PEA/PEAD - P-Series AC - 0_PEA-A18AA4/PUY-A18NHA4

PEA/PEAD - P-Series AC


Model Number: 0_PEA-A18AA4/PUY-A18NHA4

Ceiling concealed horizontal ducted unit for applications with short duct runs. Rated capacities range from 12,000-42,000 Btu/h.


Drain Drain lift for condensate removal (21-11/16" PEA, 27-9/16" PEAD lift)
Air filter is included with indoor unit
Outside air intake capability
Auto fan mode
Multiple controller options available
Auto restart following a power outage
Self-check function—integrated diagnostics
Limited warranty: five years on parts and defects and seven years on compressors




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 12000 Btu/h (3.52 kW) *1
Cooling Capacity Range 6000 - 12000 Btu/h (1.8 - 3.5 kW)
Cooling Total Input 1240 W (1.200 kW)
Cooling Energy Efficiency SEER 13.6
Cooling Sensible Heat Factor 0.77
Cooling Moisture Removal Pints/H 2.47
Cooling EER 9.7
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.65 (MEL 56) [20]
Refrigerant Charge 1.3 [2lbs 14oz]
Refrigerant Control Linear Expansion Valve
Fan Fan Motor - F.L.A. 0.57 F.L.A
Fan Fan motor output - kW 96 W
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 247-317-388 CFM (7-9-11 m³/min)
Airflow Cooling : WET 222-285-349 CFM (6-8-10 m³/min)
Sound Pressure Level Cooling 23-28-33 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 39 Inches (990 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Voltage Indoor - Outdoor S2-S3 DC24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Galvanized

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 18000 Btu/h (5.28 kW) *1
Cooling Capacity Range 8000 - 18000 Btu/h (2.3 - 5.3 kW)
Cooling Total Input 2150 W (2.200 kW)
Cooling Energy Efficiency SEER 14.3
Cooling Sensible Heat Factor 0.8
Cooling EER 8.4
Cooling Moisture Removal Pints/H 3.26
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.65 (MEL 56) [20]
Refrigerant Charge 1.7 [3lbs 12oz]
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 96 W
Fan Fan Motor - F.L.A. 0.74 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 423-529-635 CFM (11-15-18 m³/min)
Airflow Cooling : WET 381-476-572 CFM (11-13-16 m³/min)
Sound Pressure Level Cooling 30-34-38 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 46-7/8 Inches (1190 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 18000 Btu/h (5.28 kW) *1
Cooling Capacity Range 8000 - 18000 Btu/h (2.3 - 5.3 kW)
Cooling Total Input 2150 W (2.200 kW)
Cooling Energy Efficiency SEER 14.3
Cooling Sensible Heat Factor 0.8
Cooling EER 8.4
Cooling Moisture Removal Pints/H 3.26
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Oil Type 0.65 (MEL 56) [20]
Refrigerant Type R410A
Refrigerant Charge 1.7 [3lbs 12oz]
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 96 W
Fan Fan Motor - F.L.A. 0.74 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 423-529-635 CFM (11-15-18 m³/min)
Airflow Cooling : WET 381-476-572 CFM (11-13-16 m³/min)
Sound Pressure Level Cooling 30-34-38 dB(A)
Dimensions H x W x D Height 7-7/8 Inches (200 mm)
Dimensions H x W x D Width 46-7/8 Inches (1190 mm)
Dimensions H x W x D Depth 27-9/16 Inches (700 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 24000 Btu/h (7.03 kW) *1
Cooling Capacity Range 12000 - 24000 Btu/h (3.5 - 7 kW)
Cooling Total Input 2400 W (2.400 kW)
Cooling Energy Efficiency SEER 16
Cooling Sensible Heat Factor 0.68
Cooling EER 10
Cooling Moisture Removal Pints/H 6.9
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Charge 3.0 [6 lbs 10oz]
Refrigerant Control Linear Expansion Valve
Fan Fan Motor - F.L.A. 2.1 F.L.A
Fan Fan motor output - kW 121 W
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 512-636-742 CFM (14.5-18-21 m³/min)
Airflow Cooling : WET 494-600-671 CFM (14-17-19 m³/min)
Sound Pressure Level Cooling 30-33-37 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 43-5/16 Inches (1100 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Voltage Indoor - Outdoor S2-S3 DC24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Galvanized

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 24000 Btu/h (7.03 kW) *1
Cooling Capacity Range 12000 - 24000 Btu/h (3.5 - 7 kW)
Cooling Total Input 2400 W (2.400 kW)
Cooling Energy Efficiency SEER 16
Cooling Sensible Heat Factor 0.68
Cooling EER 10
Cooling Moisture Removal Pints/H 6.9
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Charge 6 lbs 10 oz
Refrigerant Control Linear Expansion Valve
Fan Fan Motor - F.L.A. 0.75 F.L.A
External Static Pressure 0.14-0.20-0.28-0.40-0.60 In.WG (35-50-70-100-150 Pa)
Airflow Cooling : DRY 512-636-742 CFM (14.5-18-21 m³/min)
Airflow Cooling : WET 494-600-671 CFM (14-17-19 m³/min)
Sound Pressure Level Cooling 30-33-37 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 43-5/16 Inches (1100 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB -20°F** (-29°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S2-S3 DC24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 30000 Btu/h (8.79 kW) *1
Cooling Capacity Range 12000 - 30000 Btu/h (3.5 - 8.8 kW)
Cooling Total Input 3850 W (3.900 kW)
Cooling Energy Efficiency SEER 15.5
Cooling Sensible Heat Factor 0.68
Cooling EER 7.7
Cooling Moisture Removal Pints/H 8.6
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Charge 3.0 [6 lbs 10oz]
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 121 W
Fan Fan Motor - F.L.A. 2.18 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 618-742-883 CFM (17.5-21-25 m³/min)
Airflow Cooling : WET 565-671-812 CFM (16-19-23 m³/min)
Sound Pressure Level Cooling 30-34-39 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 43-5/16 mm Inches (1100 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 30000 Btu/h (8.79 kW) *1
Cooling Capacity Range 12000 - 30000 Btu/h (3.5 - 8.8 kW)
Cooling Total Input 3850 W (3.900 kW)
Cooling Energy Efficiency SEER 15.5
Cooling Sensible Heat Factor 0.68
Cooling EER 7.7
Cooling Moisture Removal Pints/H 8.6
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Charge 6 lbs 10 oz
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 121 W
Fan Fan Motor - F.L.A. 2.18 F.L.A
External Static Pressure 0.14-0.20-0.28-0.40-0.60 In.WG (35-50-70-100-150 Pa)
Airflow Cooling : DRY 618-742-883 CFM (17.5-21-25 m³/min)
Airflow Cooling : WET 565-671-812 CFM (16-19-23 m³/min)
Sound Pressure Level Cooling 30-34-39 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 43-5/16 Inches (1100 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB -20°F** (-29°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 35000 Btu/h (10.26 kW) *1
Cooling Capacity Range 12000 - 35000 Btu/h (3.5 - 10.3 kW)
Cooling Total Input 4850 W (4.900 kW)
Cooling Energy Efficiency SEER 15
Cooling Sensible Heat Factor 0.75
Cooling Moisture Removal Pints/H 7.9
Cooling EER 7.2
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Type R410A
Refrigerant Charge 3.0 [6 lbs 10oz]
Refrigerant Control Linear Expansion Valve
Fan Fan Motor - F.L.A. 2.64 F.L.A
Fan Fan motor output - kW 244 W
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 847-1024-1201 CFM (24-29-34 m³/min)
Airflow Cooling : WET 777-953-1130 CFM (22-27-32 m³/min)
Sound Pressure Level Cooling 33-38-42 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 55-1/8 Inches (1400 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S2-S3 DC24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 35000 Btu/h (10.26 kW) *1
Cooling Capacity Range 12000 - 35000 Btu/h (3.5 - 10.3 kW)
Cooling Total Input 4850 W (4.900 kW)
Cooling Energy Efficiency SEER 15
Cooling Sensible Heat Factor 0.75
Cooling Moisture Removal Pints/H 7.9
Cooling EER 7.2
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Type R410A
Refrigerant Charge 6 lbs 10 oz
Refrigerant Control Linear Expansion Valve
Fan Fan Motor - F.L.A. 2.64 F.L.A
Fan Fan motor output - kW 244 W
External Static Pressure 0.14-0.20-0.28-0.40-0.60 In.WG (35-50-70-100-150 Pa)
Airflow Cooling : DRY 847-1024-1201 CFM (24-29-34 m³/min)
Airflow Cooling : WET 777-953-1130 CFM (22-27-32 m³/min)
Sound Pressure Level Cooling 33-38-42 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 55-1/8 Inches (1400 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB -20°F** (-29°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S2-S3 DC24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 42000 Btu/h (12.31 kW) *1
Cooling Capacity Range 18000 - 42000 Btu/h (5.3 - 12.3 kW)
Cooling Total Input 5350 W (5.400 kW)
Cooling Energy Efficiency SEER 13.8
Cooling Sensible Heat Factor 0.76
Cooling Moisture Removal Pints/H 9
Cooling EER 7.8
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 1.4 (FV50S) [45]
Refrigerant Charge 4.5 [10lbs]
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 244 W
Fan Fan Motor - F.L.A. 2.8 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 1042-1254-1483 CFM (29.5-35.5-42 m³/min)
Airflow Cooling : WET 953-1165-1412 CFM (27-33-40 m³/min)
Sound Pressure Level Cooling 36-40-44 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 55-1/8 Inches (1400 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 42000 Btu/h (12.31 kW) *1
Cooling Capacity Range 18000 - 42000 Btu/h (5.3 - 12.3 kW)
Cooling Total Input 5350 W (5.400 kW)
Cooling Energy Efficiency SEER 14.0
Cooling Sensible Heat Factor 0.76
Cooling Moisture Removal Pints/H 9
Cooling EER 7.8
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 1.4 (FV50S) [45]
Refrigerant Charge 6 lbs 10 oz
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 244 W
Fan Fan Motor - F.L.A. 2.8 F.L.A
External Static Pressure 0.14-0.20-0.28-0.40-0.60 In. WG (35-50-70-100-150 Pa)
Airflow Cooling : DRY 1042-1254-1483 CFM (29.5-35.5-42 m³/min)
Airflow Cooling : WET 953-1165-1412 CFM (27-33-40 m³/min)
Sound Pressure Level Cooling 36-40-44 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 55-1/8 Inches (1400 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
External Finish Galvanized
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com

Sweets app for Revit – Learn More