MXZ-C - M-Series Heat Pumps - Outdoor Units (Multi Zone) - 0_MXZ-3C30NA

MXZ-C - M-Series Heat Pumps - Outdoor Units (Multi Zone)


Model Number: 0_MXZ-3C30NA

Total zone control is now available in any climate with the newest addition of the MXZ systems to the M-Series Hyper-Heating INVERTER™ family. Heat and cool from 2 to 8 zones with only one extremely quiet outdoor unit.


A six unit lineup which gives the ability to heat and cool two to eight individual zones with 20kBtu/h – 48kBtu/h.
Heating capacities ranging from 22kBtu/h – 54kBtu/h.
High efficiencies up to 19.0 SEER, 14.0 EER and 13.5 HSPF.
Connection to our new MSZ-FH indoor units, featuring i-see Sensor ™ 3D.
Built-in base pan heaters to prevent ice buildup in the drain pan.
An optional M-NET adapter which allows easy integration into the CMCN systems.
Advanced LEV controls which allow installers to use longer line lengths and increase vertical separations.
ENERGY STAR® qualification for every unit.
A new branch box featuring decreased size, multi-positional mounting, and no need for a drain line. (Required on 4-, 5-, and 8-zone units).




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 18,000 / 20,000 Btu/h (5.3 - 5.9 kW) *1
Cooling Capacity Range 12,600 - 20,000 Btu/h (3.7 - 5.9 kW)
Cooling Rated Total Input 1,334 / 1,819 W
Cooling Energy Efficiency SEER 17.0 / 15.0
Heating at 47° F Rated Capacity 22,000 / 22,000 Btu/h (6.4 / 6.4 kW) *2
Heating at 47° F Capacity Range 11,400 - 25,500 Btu/h (3.3 / 7.5 kW)
Heating at 47° F Rated Total Input 1,450 / 1,588 W
Heating at 47° F HSPF (Region IV) 9.8 / 9.5
Heating at 17° F Maximum Capacity 22,000 / 22,000 Btu/h (6.4 / 6.4 kW)
Heating at 17° F COP 2.77 / 2.53
Heating at 5° F Maximum Capacity 22000 Btu/h (6.4 kW)
Minimum Circuit Ampacity MCA 29 Ampere *4
Maximum fuse size (time delay) MOCP 40 Ampere *4
Recommended Fuse/Breaker Size 40 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 8 Lbs. 14 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 58 dB(A)
Sound Pressure Level Cooling 54 dB(A)
Dimensions H x W x D Height 41-9/32 Inches (1048 mm)
Dimensions H x W x D Width 37-13/32 (950 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A,B: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 164 Ft. (50 m)
Number of Indoor Units 2
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49 ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 22,000 / 23,600 Btu/h (6.4 / 6.9 kW) *1
Cooling Capacity Range 12,600-22,000 / 12,600-25,500 Btu/h (3.7-6.4 / 3.7-7.3 kW)
Cooling Rated Total Input 1620 / 2100 W
Cooling Energy Efficiency SEER 13.6 / 11.2
Heating at 47° F Rated Capacity 25,000 / 24,600 Btu/h (7.3 / 7.2 kW) *2
Heating at 47° F Capacity Range 11,400-30,600 / 11,400-29,400 Btu/h (3.3-9 / 3.3-8.6 kW)
Heating at 47° F Rated Total Input 1750 / 1900 W
Heating at 47° F HSPF (Region IV) 9.8 / 9.2
Heating at 17° F Maximum Capacity 19,600 / 19,600 Btu/h (5.7 / 5.7 kW)
Heating at 17° F COP 2.97 / 2.61
Heating at 5° F Maximum Capacity 18200 Btu/h (5.3 kW)
Minimum Circuit Ampacity MCA 22.1 *4
Maximum fuse size (time delay) MOCP 25 *4
Recommended Fuse/Breaker Size 25
Refrigerant Type R410A
Refrigerant Oil Type 6Lbs. 13oz.
Refrigerant Charge 6Lbs. 13oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 55 dB(A)
Sound Pressure Level Cooling 51 dB(A)
Dimensions H x W x D Height 37-13/32
Dimensions H x W x D Width 31-11/32
Dimensions H x W x D Depth 13
Refrigerant Pipe Size O.D. Gas (Low Pressure) A port:4/8 (12.7) Other:3/8 (9.52)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 2/8 (6.35)
Maximum Refrigerant Pipe Length 230Ft. (70 m)
Number of Indoor Units 3
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49Ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49Ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82Ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 22,000 / 23,600 Btu/h (6.4 / 6.9 kW) *1
Cooling Capacity Range 12,600 - 23,600 Btu/h (3.7 - 6.9 kW)
Cooling Rated Total Input 1,630 / 2,360 W
Cooling Energy Efficiency SEER 19.0 / 15.5
Heating at 47° F Rated Capacity 25,000 / 24,600 Btu/h (7.3 / 7.2 kW) *2
Heating at 47° F Capacity Range 11,400 - 30,600 Btu/h (3.3 / 9 kW)
Heating at 47° F Rated Total Input 1,622 / 1,635 W
Heating at 47° F HSPF (Region IV) 10.0 / 9.0
Heating at 17° F Maximum Capacity 25,000 / 24, 600 Btu/h (7.3 / 7.2 kW)
Heating at 17° F COP 2.53 / 2.51
Heating at 5° F Maximum Capacity 25000 Btu/h (7.3 kW)
Minimum Circuit Ampacity MCA 30 Ampere *4
Maximum fuse size (time delay) MOCP 40 Ampere *4
Recommended Fuse/Breaker Size 40 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 8 Lbs. 14 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 58 dB(A)
Sound Pressure Level Cooling 54 dB(A)
Dimensions H x W x D Height 41-9/32 Inches (1048 mm)
Dimensions H x W x D Width 37-13/32 (950 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A:1/2 Inch (12.7 mm), B,C: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 230 Ft. (70 m)
Number of Indoor Units 3
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49 ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 28,400 / 27,400 Btu/h *1
Cooling Capacity Range 12,600-28,400 / 12,600-27,400 Btu/h (3.7-8.3 / 3.7-8 kW)
Cooling Rated Total Input 2680 / 2840 W
Cooling Energy Efficiency SEER 10.6 / 9.6
Heating at 47° F Rated Capacity 28,600 / 27,600 Btu/h (8.4 / 8.1 kW) *2
Heating at 47° F Capacity Range 11,400-36,000 / 11,400-35,000 Btu/h (3.3-10.5 / 3.3-10.2 kW)
Heating at 47° F Rated Total Input 2150 / 2220 W
Heating at 47° F HSPF (Region IV) 10.6 / 9.6
Heating at 17° F Maximum Capacity 21,000 / 21,000 Btu/h (6.1 / 6.1 kW)
Heating at 17° F COP 2.77 / 2.78
Heating at 5° F Maximum Capacity 18200 Btu/h (5.3 kW)
Minimum Circuit Ampacity MCA 22.1 *4
Maximum fuse size (time delay) MOCP 25 *4
Recommended Fuse/Breaker Size 25
Refrigerant Type R410A
Refrigerant Oil Type 6Lbs. 13oz.
Refrigerant Charge 6Lbs. 13oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 56 dB(A)
Sound Pressure Level Cooling 52 dB(A)
Dimensions H x W x D Height 37-13/32
Dimensions H x W x D Width 31-11/32
Dimensions H x W x D Depth 13
Refrigerant Pipe Size O.D. Gas (Low Pressure) A port:4/8 (12.7) Other:3/8 (9.52)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 2/8 (6.35)
Maximum Refrigerant Pipe Length 230Ft. (70 m)
Number of Indoor Units 3
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49Ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49Ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82Ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 28,400 / 27,400 Btu/h (8.3 / 8 kW) *1
Cooling Capacity Range 12,600 - 28,400 Btu/h (3.7 - 8.3 kW)
Cooling Rated Total Input 2,272 / 2,661 W
Cooling Energy Efficiency SEER 18.0 / 16.0
Heating at 47° F Rated Capacity 28,600 / 27, 600 Btu/h (8.4 / 8.1 kW) *2
Heating at 47° F Capacity Range 11,400 - 36,000 Btu/h (3.3 / 10.5 kW)
Heating at 47° F Rated Total Input 1,991 / 1,993 W
Heating at 47° F HSPF (Region IV) 11.0 / 9.8
Heating at 17° F Maximum Capacity 28,600 / 27, 600 Btu/h (8.4 / 8.1 kW)
Heating at 17° F COP 2.65 / 2.5
Heating at 5° F Maximum Capacity 28600 Btu/h (8.4 kW)
Minimum Circuit Ampacity MCA 30 Ampere *4
Maximum fuse size (time delay) MOCP 40 Ampere *4
Recommended Fuse/Breaker Size 40 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 8 Lbs. 14 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 58 dB(A)
Sound Pressure Level Cooling 54 dB(A)
Dimensions H x W x D Height 41-9/32 Inches (1048 mm)
Dimensions H x W x D Width 37-13/32 Inches (950 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A:1/2 Inch (12.7 mm), B,C: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 230 Ft. (70 m)
Number of Indoor Units 3
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49 ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 35,400 / 34,400 Btu/h *1
Cooling Capacity Range 12,600-36,400 / 12,600-34,800 Btu/h (3.7-10.7/ 3.7-10.2 kW)
Cooling Rated Total Input 3760 / 3940 W
Cooling Energy Efficiency SEER 9.4 / 8.7
Heating at 47° F Rated Capacity 36,000 / 34,400 Btu/h (10.5 / 10.1 kW) *2
Heating at 47° F Capacity Range 11,400-43,000 / 11,400-41,400 Btu/h (3.3-12.6 / 3.3-12.1 kW)
Heating at 47° F Rated Total Input 3020 / 3100 W
Heating at 47° F HSPF (Region IV) 11.0 / 9.8
Heating at 17° F Maximum Capacity 26,600 / 26,600 Btu/h (7.8 / 7.8 kW)
Heating at 17° F COP 2.67 / 2.54
Heating at 5° F Maximum Capacity 18200 Btu/h (5.3 kW)
Minimum Circuit Ampacity MCA 23.1 *4
Maximum fuse size (time delay) MOCP 25 *4
Recommended Fuse/Breaker Size 25
Refrigerant Type R410A
Refrigerant Oil Type 6Lbs. 13oz.
Refrigerant Charge 6Lbs. 13oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 56 dB(A)
Sound Pressure Level Cooling 54 dB(A)
Dimensions H x W x D Height 37-13/32
Dimensions H x W x D Width 31-11/32
Dimensions H x W x D Depth 13
Refrigerant Pipe Size O.D. Gas (Low Pressure) A port:4/8 (12.7) Other:3/8 (9.52)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 2/8 (6.35)
Maximum Refrigerant Pipe Length 230Ft. (70 m)
Number of Indoor Units 4
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49Ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49Ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82Ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 36,000 / 36,000 Btu/h (10.5 / 10.5 kW) *1
Cooling Capacity Range 6,000 - 36,000 Btu/h (1.8 - 10.5 kW)
Cooling Rated Total Input 2,570 / 3,180 W
Cooling Energy Efficiency SEER 19.1 / 15.8
Heating at 47° F Rated Capacity 45,000 / 45,000 Btu/h (13.2 / 13.2 kW) *2
Heating at 47° F Capacity Range 7,200 - 45,000 Btu/h (2.1 - 13.2 kW)
Heating at 47° F Rated Total Input 3,340 / 4,250 W
Heating at 47° F HSPF (Region IV) 11.3 / 10.1
Heating at 17° F Maximum Capacity 45,000 / 45,000 Btu/h (13.2 / 13.2 kW)
Heating at 17° F COP 2.85 / 2.3
Heating at 5° F Maximum Capacity 45000 Btu/h (13.2 kW)
Minimum Circuit Ampacity MCA 42 Ampere *4
Maximum fuse size (time delay) MOCP 52 Ampere *4
Recommended Fuse/Breaker Size 50 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 10 Lbs. 9 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 53 dB(A)
Sound Pressure Level Cooling 49 dB(A)
Dimensions H x W x D Height 13 Inches (330 mm)
Dimensions H x W x D Width 41-11/32 Inches (1050 mm)
Dimensions H x W x D Depth 52-11/16 Inches (1338 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 5/8 Inch (15.88 mm)
Maximum Refrigerant Pipe Length 492 Ft. (150 m)
Number of Indoor Units 2-4
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 131 Ft. (40 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 164 Ft. (50 m)
Maximum Piping Length for Each Indoor Unit 262 Ft. (80 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 40,500 / 37,500 Btu/h (11.9 - 11 kW) *1
Cooling Capacity Range 12,600 - 43,000 Btu/h ( 3.7 - 12.6 kW)
Cooling Rated Total Input 4.435 / 4,167 W
Cooling Energy Efficiency SEER 19.7 / 15.2
Heating at 47° F Rated Capacity 45,000 / 41,000 Btu/h (13 / 12 kW) *2
Heating at 47° F Capacity Range 11,400 - 53,600 Btu/h
Heating at 47° F Rated Total Input 2,943 / 2,869 W
Heating at 47° F HSPF (Region IV) 10.3 / 9.1
Heating at 17° F Maximum Capacity 30,500 / 29,100 Btu/h (9 / 8.5 kW)
Heating at 5° F Maximum Capacity 26000 Btu/h (7.6 kW)
Minimum Circuit Ampacity MCA 32 Ampere *4
Maximum fuse size (time delay) MOCP 40 Ampere *4
Recommended Fuse/Breaker Size 40 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 8 Lbs. 14 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 58 dB(A)
Sound Pressure Level Cooling 56 dB(A)
Dimensions H x W x D Height 41-9/32 Inches (1048 mm)
Dimensions H x W x D Width 37-13/32 (950 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A:1/2 Inch (12.7 mm), B,C,D,E: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 262 Ft. (80 m)
Number of Indoor Units 5
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 49 ft. (15 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 42,000 / 42,000 Btu/h (12.3 / 12.3 kW) *1
Cooling Capacity Range 6,000 - 42,000 Btu/h (1.8 - 12.3 kW)
Cooling Rated Total Input 3,130 / 3,890 W
Cooling Energy Efficiency SEER 19.0 / 15.0
Heating at 47° F Rated Capacity 48,000 / 48,000 Btu/h (14 / 14 kW) *2
Heating at 47° F Capacity Range 7,200 - 48,000 Btu/h (2.1 - kW)
Heating at 47° F Rated Total Input 3,430 / 4,350 W
Heating at 47° F HSPF (Region IV) 11.0 / 10.1
Heating at 17° F Maximum Capacity 48,000 / 48,000 Btu/h (14 / 14 kW)
Heating at 17° F COP 2.85 / 2.5
Heating at 5° F Maximum Capacity 48000 Btu/h (14 kW)
Minimum Circuit Ampacity MCA 42 Ampere *4
Maximum fuse size (time delay) MOCP 52 Ampere *4
Recommended Fuse/Breaker Size 50 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 10 Lbs. 9 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 54 dB(A)
Sound Pressure Level Cooling 50 dB(A)
Dimensions H x W x D Height 13 Inches (330 mm)
Dimensions H x W x D Width 41-11/32 Inches (1050 mm)
Dimensions H x W x D Depth 52-11/16 Inches (1338 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 5/8 Inch (15.88 mm)
Maximum Refrigerant Pipe Length 492 Ft. (150 m)
Number of Indoor Units 2-5
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 131 Ft. (40 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 164 Ft. (50 m)
Maximum Piping Length for Each Indoor Unit 262 Ft. (80 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 48,000 / 48,000 Btu/h (14.1 / 14.1 kW) *1
Cooling Capacity Range 6,000 - 48,000 Btu/h (1.8 - 14.1 kW)
Cooling Rated Total Input 4,000 / 5,050 W
Cooling Energy Efficiency SEER 18.9 / 14.7
Heating at 47° F Rated Capacity 54,000 / 54,000 Btu/h (15.8 / 15.8 kW) *2
Heating at 47° F Capacity Range 7,200 - 54,000 Btu/h (2.1 - 15.8 kW)
Heating at 47° F Rated Total Input 4,220 / 4,990 W
Heating at 47° F HSPF (Region IV) 11.4 / 10.1
Heating at 17° F Maximum Capacity 36,600 / 36,600 Btu/h (10.5 / 10.5 kW)
Heating at 5° F Maximum Capacity 32400 Btu/h (9.5 kW)
Minimum Circuit Ampacity MCA 37 Ampere *4
Maximum fuse size (time delay) MOCP 52 Ampere *4
Recommended Fuse/Breaker Size 40 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 10 Lbs. 9 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 54 dB(A)
Sound Pressure Level Cooling 51 dB(A)
Dimensions H x W x D Height 13 Inches (330 mm)
Dimensions H x W x D Width 41-11/32 Inches (1050 mm)
Dimensions H x W x D Depth 52-11/16 Inches (1338 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 5/8 Inch (15.88 mm)
Maximum Refrigerant Pipe Length 492 Ft. (150 m)
Number of Indoor Units 2-8
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 131 Ft. (40 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 164 Ft. (50 m)
Maximum Piping Length for Each Indoor Unit 262 Ft. (80 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 48,000 / 48,000 Btu/h (14.1 / 14.1 kW) *1
Cooling Capacity Range 6,000 - 48,000 Btu/h (1.8 - 14.1 kW)
Cooling Rated Total Input 4,000 / 5,050 W
Cooling Energy Efficiency SEER 18.9 / 14.7
Heating at 47° F Rated Capacity 54,000 / 54,000 Btu/h (15.8 / 15.8 kW) *2
Heating at 47° F Capacity Range 7200 - 54,000 Btu/h (2.1 - 15.8 kW)
Heating at 47° F Rated Total Input 4,220 / 4,990 W
Heating at 47° F HSPF (Region IV) 11.0 / 10.0
Heating at 17° F Maximum Capacity 54,000 / 54,000 Btu/h (15.8 / 15.8 kW)
Heating at 17° F COP 2.7 / 2.4
Heating at 5° F Maximum Capacity 54000 Btu/h (15.8 kW)
Minimum Circuit Ampacity MCA 42 Ampere *4
Maximum fuse size (time delay) MOCP 52 Ampere *4
Recommended Fuse/Breaker Size 50 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S
Refrigerant Charge 10 Lbs. 9 oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Heating 54 dB(A)
Sound Pressure Level Cooling 51 dB(A)
Dimensions H x W x D Height 13 Inches (330 mm)
Dimensions H x W x D Width 41-11/32 Inches (1050 mm)
Dimensions H x W x D Depth 52-11/16 Inches (1338 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 5/8 Inch (15.88 mm)
Maximum Refrigerant Pipe Length 492 Ft. (150 m)
Number of Indoor Units 2-8
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 131 Ft. (40 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 164 Ft. (50 m)
Maximum Piping Length for Each Indoor Unit 262 Ft. (80 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB
External Finish Munsell No. 3Y 7.8/11