Overview



MXZ-B - M-Series Heat Pumps - Outdoor Units (Multi Zone) - 0_MXZ-5B42NA

MXZ-B - M-Series Heat Pumps - Outdoor Units (Multi Zone)


Model Number: 0_MXZ-5B42NA

Total zone control: individually controlled rooms (up to 8) with a single outdoor system


Individual zone control
Mix and match flexibility of indoor unit styles and combinations
A wide range of indoor unit capacities that match the room size and requirements
Flexible design options to tackle the most challenging multi-room installations
Simple, quick, and cost–effective installation keeps install costs down on new construction and disruption to a minimum on renovations and refits
Efficient systems, including multiple options that meet ENERGY STAR requirements




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 18000 / 20000 Btu/h (5.3 / 5.9 kW) *1
Cooling Capacity Range 7800 - 20000 Btu/h (2.3 - 5.9 kW)
Cooling Total Input 2190 W (2.2 kW)
Cooling Energy Efficiency SEER 18
Cooling EER 12.5
Heating at 47° F Rated Capacity 22000 / 22000 Btu/h (6.4 / 6.4 kW) *2
Heating at 47° F Capacity Range 8500 - 25500 Btu/h (2.5 - 7.5 kW)
Heating at 47° F Total Input 2620 (520 - 2620) W
Heating at 47° F HSPF (Region IV) 8.9
Heating at 47° F COP 3.9
Heating at 17° F Maximum Capacity 14500 / 12500 Btu/h (4.2 / 3.7 kW)
Heating at 17° F COP 2.7 Btu/Btu
Heating at 17° F Total Input 1350 / 1430 W
Heating at 17° F Rated Capacity 12500 / 12500 Btu/h (3.7 / 3.7 kW) *3
Heating at 5° F Maximum Capacity 11113 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 15 Ampere *4
Maximum fuse size (time delay) MOCP 20 Ampere *4
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Oil Type NEO22 (23.7)
Refrigerant Type R410A
Refrigerant Charge 5 Lbs., 15 Oz.
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model SNB130FQBH1
Compressor L.R.A. 15
Compressor R.L.A. 10.1
Fan Fan Motor - F.L.A. 0.96 F.L.A
Airflow Cooling 1485 CFM (42 m³/min)
Airflow Heating 1640 CFM (46 m³/min)
Sound Pressure Level Cooling 49 dB(A)
Sound Pressure Level Heating 51 dB(A)
Dimensions H x W x D Height 27-15/16 Inches (710 mm)
Dimensions H x W x D Width 33-1/16 Inches (840 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A,B: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 164 ft. (50 m)
Number of Indoor Units 2
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 33 ft. (10 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 6°F (-14°C) DB, 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 6°F (-14°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Defrost Method Reverse Cycle
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Munsell 3Y 7.8/1.1

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 22000 / 23600 Btu/h (6.4 / 6.9 kW) *1
Cooling Capacity Range 12600 - 25500 Btu/h (3.7 - 7.5 kW)
Cooling Total Input 2460 W (2.5 kW)
Cooling Energy Efficiency SEER 17.5
Cooling EER 12.5
Heating at 47° F Rated Capacity 25000 / 24600 Btu/h (7.3 / 7.2 kW) *2
Heating at 47° F Capacity Range 11400 - 30600 Btu/h (3.3 - 9 kW)
Heating at 47° F Total Input 1900 (740 - 2600) W
Heating at 47° F HSPF (Region IV) 9.3
Heating at 47° F COP 4.2
Heating at 17° F Maximum Capacity 18800 / 17000 Btu/h (5.5 / 5 kW)
Heating at 17° F COP 2.98 Btu/Btu
Heating at 17° F Total Input 1380 / 1570 W
Heating at 17° F Rated Capacity 14000 / 14000 Btu/h (4.1 / 4.1 kW) *3
Heating at 5° F Maximum Capacity 13336 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 18 Ampere *4
Maximum fuse size (time delay) MOCP 20 Ampere *4
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Oil Type NEO22 (29.4)
Refrigerant Type R410A
Refrigerant Charge 7, 11
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCH
Compressor L.R.A. 15
Compressor R.L.A. 11
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 2068 CFM (59 m³/min)
Airflow Heating 1605 CFM (45 m³/min)
Sound Pressure Level Cooling 54 dB(A)
Sound Pressure Level Heating 49 dB(A)
Dimensions H x W x D Height 35-7/16 Inches (900 mm)
Dimensions H x W x D Width 35-7/16 Inches (900 mm)
Dimensions H x W x D Depth 12-5/8 Inches (321 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A: 1/2 Inch (12.7 mm) ; B,C: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 230 ft. (70 m)
Number of Indoor Units 2, 3
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 33 ft. (10 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 6°F (-14°C) DB, 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 6°F (-14°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Defrost Method Reverse Cycle

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 28400 Btu/h (8.32 kW) *1
Cooling Capacity Range 12600 - 28400 Btu/h (3.7 - 8.3 kW)
Cooling Total Input 3330 W (3.3 kW)
Cooling Energy Efficiency SEER 17.5
Cooling EER 9.1
Heating at 47° F Rated Capacity 28600 / 27600 Btu/h (8.4 / 8.1 kW) *2
Heating at 47° F Capacity Range 11400 - 36000 Btu/h (3.3 - 10.6 kW)
Heating at 47° F Total Input 2220 (740 - 2820) W
Heating at 47° F HSPF (Region IV) 10.5
Heating at 47° F COP 3.9
Heating at 17° F Maximum Capacity 18800 / 18000 Btu/h (5.5 / 5.3 kW)
Heating at 17° F COP 2.78 Btu/Btu
Heating at 17° F Rated Capacity 16000 / 15100 Btu/h (4.7 / 4.4 kW) *3
Heating at 17° F Total Input 2120 / 2140 W
Heating at 5° F Maximum Capacity 15407 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 18 Ampere *4
Maximum fuse size (time delay) MOCP 20 Ampere *4
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NEO22 (29.4)
Refrigerant Charge 7, 11
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCH
Compressor R.L.A. 11
Compressor L.R.A. 15
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 1365 CFM (39 m³/min)
Airflow Heating 1605 CFM (45 m³/min)
Sound Pressure Level Cooling 49 dB(A)
Sound Pressure Level Heating 49 dB(A)
Dimensions H x W x D Height 35-7/16 Inches (900 mm)
Dimensions H x W x D Width 35-7/16 Inches (900 mm)
Dimensions H x W x D Depth 12-5/8 Inches (321 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A: 1/2 Inch (12.7 mm) ; B,C,D: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 230 ft. (70 m)
Number of Indoor Units 2, 3
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 33 ft. (10 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 6°F (-14°C) DB, 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 6°F (-14°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Defrost Method Reverse Cycle
External Finish Munsell 3Y 7.8/1.1

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 35400 Btu/h (10.38 kW) *1
Cooling Capacity Range 12600 - 36400 Btu/h (3.7 - 10.7 kW)
Cooling Total Input 3940 W (3.9 kW)
Cooling Energy Efficiency SEER 18
Cooling EER 9.4
Heating at 47° F Rated Capacity 36000 / 34400 Btu/h (10.6 / 10.1 kW) *2
Heating at 47° F Capacity Range 11400 - 43000 Btu/h (3.3 - 12.6 kW)
Heating at 47° F Total Input 3100 (740 - 3940) W
Heating at 47° F HSPF (Region IV) 9.3
Heating at 47° F COP 3.5
Heating at 17° F Maximum Capacity 24600 / 25400 Btu/h (7.2 / 7.4 kW)
Heating at 17° F COP 2.68 Btu/Btu
Heating at 17° F Rated Capacity 22200 / 20300 Btu/h (6.5 / 5.9 kW) *3
Heating at 17° F Total Input 2430 / 2430 W
Heating at 5° F Maximum Capacity 18671 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 23 Ampere *4
Maximum fuse size (time delay) MOCP 25 Ampere *4
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NEO22 (29.4)
Refrigerant Charge 8, 13
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCH
Compressor R.L.A. 14.4
Compressor L.R.A. 15
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 2068 CFM (59 m³/min)
Airflow Heating 2068 CFM (59 m³/min)
Sound Pressure Level Heating 57 dB(A)
Sound Pressure Level Cooling 54 dB(A)
Dimensions H x W x D Height 35-7/16 Inches (900 mm)
Dimensions H x W x D Width 35-7/16 Inches (900 mm)
Dimensions H x W x D Depth 12-5/8 Inches (321 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A: 1/2 Inch (12.7 mm) ; B,C,D: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 230 ft. (70 m)
Number of Indoor Units 2, 3, 4
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 33 ft. (10 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 6°F (-14°C) DB, 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 5°F (-15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 6°F (-14°C) DB
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Defrost Method Reverse Cycle

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *8
Cooling Rated Capacity 40,800 / 37,200 Btu/h (11.9 / 10.9 kW) *1
Cooling Capacity Range 12,600 - 43,000 Btu/h ( 3.7 - 12.6 kW)
Cooling Total Input 4,800 W (4.8 kW)
Cooling Energy Efficiency SEER 18.4
Heating at 47° F Rated Capacity 45,200 / 41,200 Btu/h (13.24 - 12 kW) *2
Heating at 47° F Capacity Range 11,400 - 53,600 Btu/h (3.3 - 15.7 kW)
Heating at 47° F Total Input 3,780 W (3.7 kW)
Heating at 47° F HSPF (Region IV) 9.8
Heating at 17° F Maximum Capacity 30,500 / 29,100 Btu/h (8.9 - 8.5 kW)
Heating at 17° F COP 2.44 Btu/Btu
Heating at 5° F Maximum Capacity 26,000 Btu/h (7.6 kW)
Minimum Circuit Ampacity MCA 36.2 Ampere *4
Maximum fuse size (time delay) MOCP 40 Ampere *4
Recommended Fuse/Breaker Size 40 Ampere
Refrigerant Type R410A
Refrigerant Oil Type FV50S (36.2)
Refrigerant Charge 10 Lbs. 9 Oz.
Compressor Type DC INVERTER-driven Twin Rotary
Sound Pressure Level Cooling 58 dB(A)
Sound Pressure Level Heating 58 dB(A)
Dimensions H x W x D Height 35-7/16 Inches (900 mm)
Dimensions H x W x D Width 12-19/32 Inches (320 mm)
Dimensions H x W x D Depth 42-1/8 Inches (1070 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) A: 1/2 Inch (12.7 mm) ; B,C,D,E: 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Length 262 Ft. (80 m)
Number of Indoor Units 2,3,4,5
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 49 ft. (15 m) *9
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit 33 ft. (10 m)
Maximum Piping Length for Each Indoor Unit 82 ft. (25 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared/Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 6°F (-14°C) DB, 5°F (-15°C) WB
External Finish Munsell No. 3.0Y 7.8 / 1.1

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V
Cooling Rated Capacity 48000 / 48000 Btu/h (14 / 14 kW) *1
Cooling Capacity Range 48000 - 54000 Btu/h (14.1 - 15.8 kW)
Cooling Total Input 5780 / 6470 Btu/h (1.69 / 1.89 kW)
Cooling Energy Efficiency SEER 15
Cooling EER 8.3
Heating at 47° F Rated Capacity 54000 / 54000 Btu/h (15.8 / 15.8 kW) *2
Heating at 47° F Total Input 4820 / 5270 W
Heating at 47° F HSPF (Region IV) 8.7
Heating at 47° F COP 3.32
Heating at 17° F Maximum Capacity 36600 / 36500 Btu/h (10.7 / 10.69 kW)
Heating at 17° F COP 2.3 Btu/Btu
Heating at 17° F Total Input 2950 W
Heating at 17° F Rated Capacity 33000 / 34700 Btu/h (9.7 / 10.16 kW) *3
Heating at 5° F Maximum Capacity 32400 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 32 Ampere
Recommended Fuse/Breaker Size 50 Ampere
Refrigerant Oil Type FV50S (73)
Refrigerant Type R410A
Refrigerant Charge 18, 11.2
Refrigerant Control Linear Expansion Valve
Compressor Type INVERTER-driven Scroll Hermetic
Compressor Model ANB33FDSMT
Airflow Cooling 3530 CFM (100 m³/min)
Airflow Heating 3530 CFM (100 m³/min)
Sound Pressure Level Cooling 54 dB(A)
Sound Pressure Level Heating 55 dB(A)
Dimensions H x W x D Height 53-3/16 Inches (1,350 mm)
Dimensions H x W x D Width 37-7/16 Inches (950 mm)
Dimensions H x W x D Depth 13 + 1-3/16 Inches (330 + 30 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (15.88 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Maximum Refrigerant Pipe Length 377 ft. (115 m)
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit 66 ft. (20 m) *4
Maximum Refrigerant Pipe Height Difference If Indoor Unit is Below Outdoor Unit - Inches (Meter) 98 ft. (30 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V