MSZ-D/MUZ-D - M-Series Heat Pump Systems - 0_MUZ-D36NA-1

MSZ-D/MUZ-D - M-Series Heat Pump Systems


Model Number: 0_MUZ-D36NA-1

Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEV's provide higher efficiency with controlled power usage. The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restored when power returns.


Complete individual Zone/Room control for exceptional comfort
High capacity with good performance allows maximum comfort with controlled capacity and power consumption in larger rooms
INVERTER driven compressor and LEV provide high efficiency comfort while using only the energy needed to maintain maximum performance
Choice of fan speeds: Low, Medium 1, Medium 2, and High, ; Auto fan speed feature also included
Wide Vane / Swing Mode increases horizontal vane travel for up to 150 degree air flow pattern
Advanced microprocessor technology and control
Equipped with standard Wireless, IR, Handheld, Remote Controller also offers optional Wireless, RFI-RedLINK™, Full Function, Wall-mount, Remote Controller - MHK1 or Wired Full Function Wall-mount Remote Controller - PAR-21MA
Hot-start technology - no cold air rush at start-up or re-start after defrost
Indoor unit powered from outdoor unit using A-Control
Automatic restart following a power outage




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 30700 Btu/h (9 kW) *1
Cooling Capacity Range 9800 - 30700 Btu/h (2.9 - 9 kW)
Cooling Total Input 3850 W (3.9 kW)
Cooling Energy Efficiency SEER 14.5
Cooling Sensible Heat Factor 0.64
Cooling Moisture Removal Pints/H 9.9
Cooling EER 8
Heating at 47° F Rated Capacity 32600 Btu/h (9.6 kW) *2
Heating at 47° F Capacity Range 8700 - 34000 Btu/h (2.6 - 10 kW)
Heating at 47° F Total Input 3360 (520 - 3600) W
Heating at 47° F HSPF (Region IV) 8.2
Heating at 47° F COP 2.84
Heating at 17° F Maximum Capacity 20800 Btu/h (6.1 kW)
Heating at 17° F COP 2.33 Btu/Btu
Heating at 17° F Rated Capacity 19500 Btu/h (5.7 kW) *3
Heating at 5° F Maximum Capacity 16305 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 389-639-848-887 CFM (11-18-23-24 m³/min)
Airflow Cooling : WET 350-390-420-490CFM (10-11-12-14 m³/min)
Airflow Heating : WET 445-639-848-887 CFM (13-18-24-25 m³/min)
Sound Pressure Level Cooling 32-42-49-51 dB(A)
Sound Pressure Level Heating 34-42-49-50 dB(A)
Dimensions H x W x D Height 14-3/8 Inches (365 mm)
Dimensions H x W x D Width 46-1/16 Inches (1,170 mm)
Dimensions H x W x D Depth 11-5/8 Inches (295 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (16 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 14°F (-10°C) DB, 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 14°F (-10°C) DB
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
External Finish Munsell 1.0Y 9.2 / 0.2

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 33200 Btu/h (9.73 kW) *1
Cooling Capacity Range 9800 - 33200 BTU/h (2.9 - 9.7 kW)
Cooling Total Input 4360 W (4.4 kW)
Cooling Energy Efficiency SEER 14.5
Cooling Sensible Heat Factor 0.62
Cooling Moisture Removal Pints/H 11.3
Cooling EER 7.6
Heating at 47° F Rated Capacity 35200 Btu/h (10.3 kW) *2
Heating at 47° F Capacity Range 8700 - 36000 Btu/h (2.6 - 10.6 kW)
Heating at 47° F Total Input 3840 (520 - 4100) W
Heating at 47° F HSPF (Region IV) 8.2
Heating at 47° F COP 2.69
Heating at 17° F Maximum Capacity 22800 Btu/h (6.7 kW)
Heating at 17° F COP 2.23 Btu/Btu
Heating at 17° F Rated Capacity 21800 Btu/h (6.4 kW) *3
Heating at 5° F Maximum Capacity 19090 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 389-639-848-887 CFM (11-18-23-24 m³/min)
Airflow Cooling : WET 350-576-763-798 CFM (10-16-22 m³/min)
Airflow Heating : WET 445-639-848-887 CFM (13-18-24-25 m³/min)
Sound Pressure Level Heating 34-42-49-50 dB(A)
Sound Pressure Level Cooling 32-42-49-51 dB(A)
Dimensions H x W x D Height 14-3/8 Inches (365 mm)
Dimensions H x W x D Width 46-1/16 Inches (1,170 mm)
Dimensions H x W x D Depth 11-5/8 Inches (295 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (16 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (16 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 14°F (-10°C) DB, 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 30700 Btu/h (9 kW) *1
Cooling Capacity Range 9800 - 30700 BTU/h (2.9 - 9 kW)
Cooling Total Input 3850 W (3.9 kW)
Cooling Energy Efficiency SEER 14.5
Cooling Sensible Heat Factor 0.64
Cooling Moisture Removal Pints/H 9.9
Cooling EER 8
Heating at 47° F Rated Capacity 32600 Btu/h (9.6 kW) *2
Heating at 47° F Capacity Range 8700 - 34000 Btu/h (2.6 - 10 kW)
Heating at 47° F Total Input 3360 (520 - 3600) W
Heating at 47° F HSPF (Region IV) 8.2
Heating at 47° F COP 2.84
Heating at 17° F Maximum Capacity 20800 Btu/h (6.1 kW)
Heating at 17° F COP 2.33 Btu/Btu
Heating at 17° F Rated Capacity 19500 Btu/h (5.7 kW) *3
Heating at 5° F Maximum Capacity 16305 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 21 Ampere
Maximum fuse size (time delay) MOCP 25 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NE022 (29.4)
Refrigerant Charge 4, 10
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCHT
Compressor R.L.A. 16
Compressor L.R.A. 20
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 1941 CFM (55 m³/min)
Sound Pressure Level Heating 57 dB(A)
Sound Pressure Level Cooling 55 dB(A)
Dimensions H x W x D Height 33-7/16 Inches (849 mm)
Dimensions H x W x D Width 33-1/16 Inches (840 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Height Difference 50 ft. (15 m)
Maximum Refrigerant Pipe Length 100 ft. (30 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 14°F (-10°C) DB, 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Defrost Method Reverse Cycle

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 33200 Btu/h (9.73 kW) *1
Cooling Capacity Range 9800 - 33200 BTU/h (2.9 - 9.7 kW)
Cooling Total Input 4360 W (4.4 kW)
Cooling Energy Efficiency SEER 14.5
Cooling Sensible Heat Factor 0.62
Cooling Moisture Removal Pints/H 11.3
Cooling EER 7.6
Heating at 47° F Rated Capacity 35200 Btu/h (10.3 kW) *2
Heating at 47° F Capacity Range 8700 - 36000 Btu/h (2.6 - 10.6 kW)
Heating at 47° F Total Input 3840 (520 - 4100) W
Heating at 47° F HSPF (Region IV) 8.2
Heating at 47° F COP 2.69
Heating at 17° F Maximum Capacity 22800 Btu/h (6.7 kW)
Heating at 17° F COP 2.23 Btu/Btu
Heating at 17° F Rated Capacity 21800 Btu/h (6.4 kW) *3
Heating at 5° F Maximum Capacity 19090 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 21 Ampere
Maximum fuse size (time delay) MOCP 25 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Oil Type NE022 (29.4)
Refrigerant Type R410A
Refrigerant Charge 4, 10
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCHT
Compressor L.R.A. 20
Compressor R.L.A. 16
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 1941 CFM (55 m³/min)
Sound Pressure Level Cooling 56 dB(A)
Sound Pressure Level Heating 57 dB(A)
Dimensions H x W x D Height 33-7/16 Inches (849 mm)
Dimensions H x W x D Width 33-1/16 Inches (840 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 1/2 Inch (12.7 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Maximum Refrigerant Pipe Height Difference 50 ft. (15 m)
Maximum Refrigerant Pipe Length 100 ft. (30 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 14°F (-10°C) DB, 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 13°F (-11°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Defrost Method Reverse Cycle
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com

Sweets app for Revit – Learn More