Mitsubishi Electric HVAC-Proposed - MSY-D/MUY-D - M-Series AC-0_MSY-D36NA-8

MSY-D/MUY-D - M-Series AC Model Number: 0_MSY-D36NA-8 INVERTER-driven wall-mounted ductless indoor unit for residential applications. Ideal for applications such as bedrooms, garages, large open rooms, and bonus rooms. Rated capacities range from 9,000 to 34,600 Btu/h. Compact side discharge...


MasterFormat: Central Cooling Equipment | Decentralized HVAC Equipment | Decentralized Unitary HVAC Equipment...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



MSY-D/MUY-D - M-Series AC - 0_MSY-D36NA-8

MSY-D/MUY-D - M-Series AC


Model Number: 0_MSY-D36NA-8

INVERTER-driven wall-mounted ductless indoor unit for residential applications. Ideal for applications such as bedrooms, garages, large open rooms, and bonus rooms. Rated capacities range from 9,000 to 34,600 Btu/h.


Compact side discharge outdoor unit
Zone control
Quiet operation for both indoor and outdoor units
“Powerful Mode” function permits system to temporarily run at a lower/higher temperature with an increased fan speed, which quickly brings the room to the optimum comfort level
Wireless remote controller is included
Indoor unit powered from outdoor unit using A-Control
Automatic restart following a power outage
Self-check function — onboard diagnostics
Dry Mode function is standard




Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 34600 Btu/h (10.14 kW) *1
Cooling Capacity Range 9800 - 34600 Btu/h (2.9 - 10.1 kW)
Cooling Total Input 4240 W (4.2 kW)
Cooling Energy Efficiency SEER 15.1
Cooling Sensible Heat Factor 0.62
Cooling Moisture Removal Pints/H 11.9
Cooling EER 8.2
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 389 - 639 - 848 - 887 CFM (11-18-23-24 m³/min)
Airflow Cooling : WET 350-576-763-798 CFM (10-16-22-23 m³/min)
Sound Pressure Level Cooling 32 - 42 - 49 - 50 dB(A)
Dimensions H x W x D Height 14-3/8 Inches (365 mm)
Dimensions H x W x D Width 46-1/16 Inches (1,170 mm)
Dimensions H x W x D Depth 11-5/8 Inches (295 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (15.88 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (16 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 34600 Btu/h (10.14 kW) *1
Cooling Capacity Range 9800 - 34600 Btu/h (2.9 - 10.1 kW)
Cooling Total Input 4240 W (4.2 kW)
Cooling Energy Efficiency SEER 15.1
Cooling Sensible Heat Factor 0.62
Cooling Moisture Removal Pints/H 11.9
Cooling EER 8.2
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 389 - 639 - 848 - 887 CFM (11-18-23-24 m³/min)
Airflow Cooling : WET 350-576-763-798 CFM (10-16-22-23 m³/min)
Sound Pressure Level Cooling 32 - 42 - 49 - 50 dB(A)
Dimensions H x W x D Height 14-3/8 Inches (365 mm)
Dimensions H x W x D Width 46-1/16 Inches (1,170 mm)
Dimensions H x W x D Depth 11-5/8 Inches (295 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (15.88 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (16 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 30700 Btu/h (9 kW) *1
Cooling Capacity Range 9800 - 30700 Btu/h (2.9 - 9 kW)
Cooling Total Input 3380 W (3.4 kW)
Cooling Energy Efficiency SEER 16
Cooling Sensible Heat Factor 0.64
Cooling Moisture Removal Pints/H 9.9
Cooling EER 9.1
Minimum Circuit Ampacity MCA 21 Ampere
Maximum fuse size (time delay) MOCP 25 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NE022 (29.4)
Refrigerant Charge 4
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCHT
Compressor R.L.A. 16
Compressor L.R.A. 20
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 1941 CFM (55 m³/min)
Sound Pressure Level Cooling 55 dB(A) *1
Dimensions H x W x D Height 33-7/16 Inches (849 mm)
Dimensions H x W x D Width 33-1/16 Inches (840 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (16 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Maximum Refrigerant Pipe Height Difference 50 ft. (15 m)
Maximum Refrigerant Pipe Length 100 ft. (30 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
External Finish Munsell 3Y 7.8/1.1
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC 12-24V

Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 34600 Btu/h (10.14 kW) *1
Cooling Capacity Range 9800 - 34600 Btu/h (2.9 - 10.1 kW)
Cooling Total Input 4240 W (4.2 kW)
Cooling Energy Efficiency SEER 15.1
Cooling Sensible Heat Factor 0.62
Cooling Moisture Removal Pints/H 11.9
Cooling EER 8.2
Minimum Circuit Ampacity MCA 21 Ampere
Maximum fuse size (time delay) MOCP 25 Ampere
Recommended Fuse/Breaker Size 25 Ampere
Refrigerant Type R410A
Refrigerant Oil Type NE022 (29.4)
Refrigerant Charge 4
Refrigerant Control Linear Expansion Valve
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model TNB220FMCHT
Compressor L.R.A. 20
Compressor R.L.A. 16
Fan Fan Motor - F.L.A. 0.93 F.L.A
Airflow Cooling 1941 CFM (55 m³/min)
Sound Pressure Level Cooling 56 dB(A)
Dimensions H x W x D Height 33-7/16 Inches (849 mm)
Dimensions H x W x D Width 33-1/16 Inches (840 mm)
Dimensions H x W x D Depth 13 Inches (330 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (15.88 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Maximum Refrigerant Pipe Height Difference 50 ft. (15 m)
Maximum Refrigerant Pipe Length 100 ft. (30 m)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Munsell 3Y 7.8/1.1