Mitsubishi Electric HVAC-Proposed - LGH-F - Energy Recovery Ventilators-0_LGH-F600RX3-E

LGH-F - Energy Recovery Ventilators Model Number: 0_LGH-F600RX3-E Lossnay® energy recovery ventilators provide outdoor air solutions for indoor environmental quality.  Improved sound attenuation makes Lossnay® units quiet enough for places where silence is a must, such as meeting rooms and...


Category: HRV | heat recovery ventilators | heat-recovery ventilation...

MasterFormat: HVAC Air Distribution | Air Terminal Units | Central HVAC Equipment...



Mitsubishi Electric HVAC-Proposed
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



LGH-F - Energy Recovery Ventilators - 0_LGH-F600RX3-E

LGH-F - Energy Recovery Ventilators


Model Number: 0_LGH-F600RX3-E

Lossnay® energy recovery ventilators provide outdoor air solutions for indoor environmental quality.  Improved sound attenuation makes Lossnay® units quiet enough for places where silence is a must, such as meeting rooms and libraries. 


Full enthalpy heat exchange with minimal moving parts
Available with up to .50" external static pressure
Temperature energy recovery efficiencies up to 75% heating
Enthalpy recovery efficiencies as high as 69% heating and 53% cooling
Can be integrated into CITY MULTI Controls Network




Power Source Voltage, Phase, Cycle 208-230V, 1 Phase, 60Hz
Capacity 1,200 ft³/min (34 m³/min)
Power Consumption 0.810-1.290 kW
Current 3.6-5.7 Ampere
Minimum Circuit Ampacity MCA 6.9 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Sound Level (fan speed low-high-extra high) (230V) 32-39-41 dB (A)
Fan Speed (230V) Extra High - High - Low
Dimensions H x W x D Height 65-7/16 Inches (1662 mm)
Dimensions H x W x D Width 48-7/16 Inches (1230 mm)
Dimensions H x W x D Depth 31-1/2 Inches (800 mm)
Enthalpy Recovery Efficiency Heating (%) 67-62-62
Enthalpy Recovery Efficiency Cooling (%) 51-44-44
Blower 9.625 Inches Diameter Centrifugal Fan
Motor Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 units
Filter Type x Quantity Washable fiber x2
External static pressure (in. H2O) High 0.43 (in H2O)
External static pressure (in. H2O) Extra High 0.75 (in H2O)
External static pressure (in. H2O) Low 0.02 (in H2O)
Starting Current Under 14.0 A
Enthalpy recovery efficiency (%) Heating - Low 67
Enthalpy recovery efficiency (%) Heating - High 62
Enthalpy recovery efficiency (%) Heating - Extra High 62
Enthalpy recovery efficiency (%) Cooling - Low 51
Enthalpy recovery efficiency (%) Cooling - High 44
Enthalpy recovery efficiency (%) Cooling - Extra High 44
Temperature recovery efficiency (%) High 69
Temperature recovery efficiency (%) Extra High 69
Temperature recovery efficiency (%) Low 74
Operating Environment 14°F-104°F (-10°C-50°C), RH 80% or less
Minimum Circuit Capacity (MCC) (208/230V) 6.9 Ampere
Control Modes Delayed Operating Mode Time setting from HVAC controller for delayed on or off operation
Control Modes Ventilation Mode Control By-pass Damper/Heat-Cool, By-pass, AUTO
Control Modes Non-interlocked Mode Operates Independently
Control Modes Interlocked Mode Operates with CITY Multi or M and P-Series
Air Volume #N/A
Energy Transfer Heat Exchange Material Partition, spacing plate-cellulose fiber membrane
Energy Transfer Heat Exhange System Ait-to-air total heat (sensible heat + latent heat) exchange, no moving parts
Energy Transfer Lossnay® Core
Temperature Recovery Efficiency % 74-69-69
Operating Environment - Minimum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Operating Environment - Maximum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Heat Exchanger Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts
External Finish Galvanized steel sheet



Power Source Voltage, Phase, Cycle 208-230V, 1 Phase, 60Hz
Capacity 300 ft³/min (8.5 m³/min)
Power Consumption 0.146-0.278 kW
Current 0.6-1.3 Ampere
Minimum Circuit Ampacity MCA 1.7 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Sound Level (fan speed low-high-extra high) (230V) 25-32-36 dB (A)
Fan Speed (230V) Extra High - High - Low
Dimensions H x W x D Height 12-1/2 Inches (318 mm)
Dimensions H x W x D Width 40 Inches (1016 mm)
Dimensions H x W x D Depth 34-15/16 Inches (887 mm)
Enthalpy Recovery Efficiency Heating (%) 69-62-62
Enthalpy Recovery Efficiency Cooling (%) 52-44-44
Blower 9.625 Inches Diameter Centrifugal Fan
Motor Totally enclosed capacitor permanent split-phase 0.21 HP induction motor, 4 poles, 2 units
Filter Type x Quantity Washable x 2
External static pressure (in. H2O) High 0.10 (in H2O)
External static pressure (in. H2O) Extra High 0.65 (in H2O)
External static pressure (in. H2O) Low 0.02 (in H2O)
Starting Current Under 2.5 A
External Finish Galvanized steel sheet
Temperature recovery efficiency (%) Extra High 69
Temperature recovery efficiency (%) High 69
Temperature recovery efficiency (%) Low 74
Enthalpy recovery efficiency (%) Heating - High 62
Enthalpy recovery efficiency (%) Heating - Low 69
Enthalpy recovery efficiency (%) Cooling - Extra High 44
Enthalpy recovery efficiency (%) Cooling - High 44
Enthalpy recovery efficiency (%) Cooling - Low 52
Enthalpy recovery efficiency (%) Heating - Extra High 62
Operating Environment - Maximum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Control Modes Non-interlocked Mode Operates Independently
Control Modes Ventilation Mode Control By-pass Damper/Heat-Cool, By-pass, AUTO
Control Modes Delayed Operating Mode Time setting from HVAC controller for delayed on or off operation
Control Modes External Control Input Mode Accepts input signals from optional control devices or systems to activate Lossnay® unit
Control Modes Interlocked Mode Operates with CITY Multi or M and P-Series
Temperature Recovery Efficiency % 74-69-69
Heat Exchanger Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts
Operating Environment - Minimum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Operating Environment 14°F-104°F (-10°C-50°C), RH 80% or less
Energy Transfer Lossnay® Core
Energy Transfer Heat Exhange System Ait-to-air total heat (sensible heat + latent heat) exchange, no moving parts
Energy Transfer Heat Exchange Material Partition, spacing plate-cellulose fiber membrane
Air Volume #N/A
Minimum Circuit Capacity (MCC) (208/230V) 1.7 Ampere



Power Source Voltage, Phase, Cycle 208-230V, 1 Phase, 60Hz
Capacity 470 ft³/min (13.3 m³/min)
Power Consumption 0.375-0.560 kW
Current 1.6-2.5 Ampere
Minimum Circuit Ampacity MCA 3.7 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Sound Level (fan speed low-high-extra high) (230V) 31.5-37-39 dB (A)
Fan Speed (230V) Extra High - High - Low
Dimensions H x W x D Height 15-11/16 Inches (398 mm)
Dimensions H x W x D Width 39-1/2 Inches (1003 mm)
Dimensions H x W x D Depth 45-13/16 Inches (1164 mm)
Enthalpy Recovery Efficiency Heating (%) 65-62-62
Enthalpy Recovery Efficiency Cooling (%) 48-44-44
Blower 9.625 Inches Diameter Centrifugal Fan
Motor Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 units
Filter Type x Quantity Washable fiber x2
External static pressure (in. H2O) High 0.10 (in H2O)
External static pressure (in. H2O) Extra High 0.65 (in H2O)
External static pressure (in. H2O) Low 0.02 (in H2O)
Starting Current Under 5.0 Ampere
Minimum Circuit Capacity (MCC) (208/230V) 3.7 Ampere
Duct Connecting Flange 9-1/2 Inches (241 mm)
External Finish Galvanized steel sheet
Energy Transfer Heat Exchange Material Partition, spacing plate-cellulose fiber membrane
Energy Transfer Heat Exhange System Ait-to-air total heat (sensible heat + latent heat) exchange, no moving parts
Energy Transfer Lossnay® Core
Operating Environment Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Operating Environment - Maximum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Enthalpy recovery efficiency (%) Cooling - High 46
Enthalpy recovery efficiency (%) Cooling - Extra High 44
Enthalpy recovery efficiency (%) Heating - Low 71
Enthalpy recovery efficiency (%) Heating - High 64
Enthalpy recovery efficiency (%) Heating - Extra High 62
Enthalpy recovery efficiency (%) Cooling - Low 55
Temperature recovery efficiency (%) Low 77
Temperature recovery efficiency (%) High 70
Temperature recovery efficiency (%) Extra High 69
Control Modes Interlocked Mode Operates with CITY Multi or M and P-Series
Control Modes External Control Input Mode Accepts input signals from optional control devices or systems to activate Lossnay® unit
Control Modes Delayed Operating Mode Time setting from HVAC controller for delayed on or off operation
Control Modes Ventilation Mode Control By-pass Damper/Heat-Cool, By-pass, AUTO
Control Modes Non-interlocked Mode Operates Independently
Heat Exchanger Air-to-air total heat
Duct Pitch 10-3/16 Inches (259 mm)
Nominal Diameter 10 Inches (254 mm)
Temperature Recovery Efficiency % 75-72-72
Ceiling Suspension Fixture Pitch Depth 15-11/16 Inches (398 mm)
Ceiling Suspension Fixture Pitch Width 39-1/2 Inches (1003 mm)
Ceiling Suspension Fixture Pitch Height 40-9/16 Inches (1030 mm)
Operating Environment - Minimum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less



Power Source Voltage, Phase, Cycle 208-230V, 1 Phase, 60Hz
Capacity 600 ft³/min (17 m³/min)
Power Consumption 0.390-0.654 kW
Current 1.7-2.9 Ampere
Minimum Circuit Ampacity MCA 3.7 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Sound Level (fan speed low-high-extra high) (230V) 30-37-39 dB (A)
Fan Speed (230V) Extra High - High - Low
Dimensions H x W x D Height 15-11/16 Inches (398 mm)
Dimensions H x W x D Width 39-1/2 Inches (1003 mm)
Dimensions H x W x D Depth 45-13/16 Inches (1164 mm)
Enthalpy Recovery Efficiency Heating (%) 66-62-62
Enthalpy Recovery Efficiency Cooling (%) 50-44-44
Blower 9.625 Inches Diameter Centrifugal Fan
Motor Totally enclosed capacitor permanent split-phase 0.21 HP induction motor, 4 poles, 2 units
Filter Type x Quantity Washable fiber x2
External static pressure (in. H2O) High 0.48 (in H2O)
External static pressure (in. H2O) Extra High 0.80 (in H2O)
External static pressure (in. H2O) Low 0.24 (in H2O)
Starting Current Under 7.0 A
External Finish Galvanized steel sheet
Operating Environment - Maximum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Temperature recovery efficiency (%) Extra High 69
Temperature recovery efficiency (%) High 69
Temperature recovery efficiency (%) Low 73
Enthalpy recovery efficiency (%) Heating - High 62
Enthalpy recovery efficiency (%) Heating - Low 66
Enthalpy recovery efficiency (%) Cooling - Extra High 44
Enthalpy recovery efficiency (%) Cooling - High 44
Enthalpy recovery efficiency (%) Cooling - Low 50
Enthalpy recovery efficiency (%) Heating - Extra High 62
Control Modes Non-interlocked Mode Operates Independently
Control Modes Ventilation Mode Control By-pass Damper/Heat-Cool, By-pass, AUTO
Control Modes Delayed Operating Mode Time setting from HVAC controller for delayed on or off operation
Control Modes External Control Input Mode Accepts input signals from optional control devices or systems to activate Lossnay® unit
Control Modes Interlocked Mode Operates with CITY Multi or M and P-Series
Temperature Recovery Efficiency % 73-69-69
Minimum Circuit Capacity (MCC) (208/230V) 3.7 Ampere
Operating Environment - Minimum Cooling (Outdoor) 14°F-104°F (-10°C-50°C), RH 80% or less
Operating Environment 14°F-104°F (-10°C-50°C), RH 80% or less
Energy Transfer Lossnay® Core
Energy Transfer Heat Exhange System Ait-to-air total heat (sensible heat + latent heat) exchange, no moving parts
Energy Transfer Heat Exchange Material Partition, spacing plate-cellulose fiber membrane
Heat Exchanger Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts



Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com

Sweets app for Revit – Learn More