H-Generation WR2-Series - CITY MULTI VRF - Water Source - 0_PQRY-P72YHMU-A

H-Generation WR2-Series - CITY MULTI VRF - Water Source


Model Number: 0_PQRY-P72YHMU-A

W-Series units combine the convenience of water-source systems with VRF technology. These units are easily installed indoors and can be used on a range of closed water loop applications including geothermal.


Modular design up to 20 ton maximum capacity
208/230V, 3-Phase, 60Hz and 460V, 3-Phase, 60Hz options
Designed for closed water loops
Dual heat recovery - from water loop and refrigerant circuit
Self-cooling cabinet design
Inlet water temperature range: 23-113° F
Max. Total Refrigerant Piping Length: up to 2,460 feet based on model
Connects to CITY MULTI indoor units; controlled via CITY MULTI Controls Network (CMCN)
External finish: Acrylic-painted steel
May help qualify for up to a 10% commerical tax credit for the total installed cost of the CITY MULTI geothermal system




Power Source Voltage, Phase, Cycle 208 / 230V, 1-phase, 60Hz
Cooling Capacity (Nominal) 120000 Btu/h (35.2 kW) *1
Cooling Power Input (Nominal) 7.73 kW *1
Cooling Current Input (Nominal) 23.6-21.4 Ampere *1
Heating Capacity (Nominal) 135000 Btu/h (39.6 kW) *1
Heating Power Input (Nominal) 7.62 kW *1
Heating Current Input (Nominal) 23.5-21.3 Ampere *1
Minimum Circuit Ampacity MCA 30/27 Ampere
Maximum fuse size (time delay) MOCP 50/40 Ampere
Recommended Fuse/Breaker Size 30/27 Ampere
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Lubricant MEL32
Compressor Crankcase Heater 0.051 (230V)
Compressor Motor Output 8.5 kW
Compressor Starting method Inverter
Sound Pressure Level (measured in anechoic room) 51 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heatsource unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~30
Refrigerant Pipe Dimensions Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 7/8 Inch (22.2 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 / 290 psi (2 / 2 MPa)
Circulating Water Water Flow Rate 25.4 GPM (5.76m³/h)
Circulating Water Operation Volume Range 19.8 - 31.7 GPM (4.5 - 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Protection Device Compressor Over-heat protection
External Finish Acrylic painted steel plate

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 120000 Btu/h (35.2 kW) *1
Cooling Power Input (Nominal) 7.73 kW *1
Cooling Current Input (Nominal) 10.6 Ampere *1
Heating Capacity (Nominal) 135000 Btu/h (39.6 kW) *1
Heating Power Input (Nominal) 7.62 kW *1
Heating Current Input (Nominal) 10.6 Ampere *1
Minimum Circuit Ampacity MCA 14 Ampere
Maximum fuse size (time delay) MOCP 20 Ampere
Recommended Fuse/Breaker Size 14 Ampere
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Lubricant MEL32
Compressor Crankcase Heater 0.051 (230V)
Compressor Motor Output 8.5 kW
Compressor Starting method Inverter
Sound Pressure Level (measured in anechoic room) 51 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm )
Indoor unit connectable Total capacity 50~150% of heatsource unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~30
Refrigerant Pipe Dimensions Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 7/8 Inch (22.2 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 / 290 psi (2 / 2 MPa)
Circulating Water Water Flow Rate 25.4 GPM (5.76m³/h)
Circulating Water Operation Volume Range 19.8 - 31.7 GPM (4.5 - 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Compressor Over-heat protection
External Finish Acrylic painted steel plate

Power Source Voltage, Phase, Cycle 208 / 230V, 1-phase, 60Hz
Cooling Capacity (Nominal) 145400 Btu/h (42.6 kW) *1
Cooling Power Input (Nominal) 8.18 kW *3
Cooling Current Input (Nominal) 25.9-23.4 Ampere *3
Heating Capacity (Nominal) 160000 Btu/h (46.9 kW) *3
Heating Power Input (Nominal) 7.89 kW *3
Heating Current Input (Nominal) 24.3-22.0 Ampere *3
Set Model With Two PQRY-P72THMU-A
Minimum Circuit Ampacity MCA 16/15 -16/15 Ampere *3
Maximum fuse size (time delay) MOCP 25/20 - 25/20 Ampere *3
Recommended Fuse/Breaker Size 16/15 - 16/15 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 4.5 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 50 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~36
Refrigerant Pipe Dimensions Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 + 25.4 GPM (5.76 + 5.76m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 GPM (4.5 + 4.5 ~ 7.2 + 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Pipe between unit and distributor Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed
Pipe between unit and distributor Gas (Low Pressure mm) -

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 145400 Btu/h (42.6 kW) *1
Cooling Power Input (Nominal) 8.18 kW *3
Cooling Current Input (Nominal) 11.7 Ampere *3
Heating Capacity (Nominal) 160000 Btu/h (46.9 kW) *3
Heating Power Input (Nominal) 7.89 kW *3
Heating Current Input (Nominal) 11 Ampere *3
Set Model With Two PQRY-P72YHMU-A
Minimum Circuit Ampacity MCA 8 - 8 Ampere *3
Maximum fuse size (time delay) MOCP 15 - 15 Ampere *3
Recommended Fuse/Breaker Size 8 - 8 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Lubricant MEL32
Compressor Starting method Inverter
Compressor Motor Output 4.6 kW
Compressor Crankcase Heater 0.051 (230V)
Sound Pressure Level (measured in anechoic room) 50 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm )
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~36
Refrigerant Pipe Dimensions Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 + 25.4 GPM (5.76 + 5.76m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 GPM (4.5 + 4.5 ~ 7.2 + 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Pipe between unit and distributor Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed
Pipe between unit and distributor Gas (Low Pressure mm) -

Power Source Voltage, Phase, Cycle 208 / 230V, 1-phase, 60Hz
Cooling Capacity (Nominal) 169100 Btu/h (49.6 kW) *1
Cooling Power Input (Nominal) 10.02 kW *3
Cooling Current Input (Nominal) 31.4-28.4 Ampere *3
Heating Capacity (Nominal) 188000 Btu/h (55.1 kW) *3
Heating Power Input (Nominal) 10.32 kW *3
Heating Current Input (Nominal) 31.8-28.8 Ampere *3
Set Model With One PQRY-P96THMU-A / and One PQRY-P72THMU-A
Minimum Circuit Ampacity MCA 23/21 - 16/15 Ampere *3
Maximum fuse size (time delay) MOCP 40/30 - 25/20 Ampere *3
Recommended Fuse/Breaker Size 23/21 - 16/15 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor /
Compressor Lubricant MEL32 / MEL32
Compressor Crankcase Heater 0.051 (230V) / 0.051 (230V)
Compressor Motor Output 6.2 / 4.5 kW
Compressor Starting method Inverter / Inverter
Sound Pressure Level (measured in anechoic room) 51 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches / 43-5/16 Inches (551/551 mm )
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~42
Refrigerant Pipe Dimensions Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters) / 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 + 25.4 / GPM (5.76 + 5.76 / m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 / GPM (4.5 + 4.5 ~ 7.2 + 7.2 / m³/h)
Circulating Water Pressure Drop 17 / 17 kPa (2.47 / 2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75°F (15~24°C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81°F (15~27°C) D.B.
Protection Device Compressor Over-heat protection /
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection /
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) /
External Finish Acrylic painted steel plate
Pipe between unit and distributor Gas (Low Pressure mm) 3/4 (19.05 mm) Brazed / 3/4 (19.05 mm) Brazed

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 169100 Btu/h (49.6 kW) *1
Cooling Power Input (Nominal) 10.02 kW *3
Cooling Current Input (Nominal) 14.2 Ampere *3
Heating Capacity (Nominal) 188000 Btu/h (55.1 kW) *3
Heating Power Input (Nominal) 10.32 kW *3
Heating Current Input (Nominal) 14.3 Ampere *3
Set Model With One PQRY-P96YHMU-A / and One PQRY-P72YHMU-A
Minimum Circuit Ampacity MCA 11 - 8 Ampere *3
Maximum fuse size (time delay) MOCP 15 - 15 Ampere *3
Recommended Fuse/Breaker Size 11 - 8 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor /
Compressor Lubricant MEL32 / MEL32
Compressor Crankcase Heater 0.051 (230V) / 0.051 (230V)
Compressor Motor Output 6.3 / 4.6 kW
Compressor Starting method Inverter / Inverter
Sound Pressure Level (measured in anechoic room) 51 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches / 43-5/16 Inches (551/551 mm )
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~42
Refrigerant Pipe Dimensions Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters) / 1.32 Gallons (5 Liters)
Circulating Water Water Flow Rate 25.4 + 25.4 / GPM (5.76 + 5.76 / m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 / GPM (4.5 + 4.5 ~ 7.2 + 7.2 / m³/h)
Circulating Water Pressure Drop 17 / 17 kPa (2.47 / 2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection /
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) /
Protection Device Compressor Over-heat protection /
External Finish Acrylic painted steel plate
Pipe between unit and distributor Gas (Low Pressure mm) 3/4 (19.05 mm) Brazed / 3/4 (19.05 mm) Brazed

Power Source Voltage, Phase, Cycle 208 / 230V, 1-phase, 60Hz
Cooling Capacity (Nominal) 192600 Btu/h (56.4 kW) *1
Cooling Power Input (Nominal) 11.89 kW *3
Cooling Current Input (Nominal) 37.0-33.4 Ampere *3
Heating Capacity (Nominal) 216000 Btu/h (63.3 kW) *3
Heating Power Input (Nominal) 12.74 kW *3
Heating Current Input (Nominal) 39.3-35.5 Ampere *3
Set Model With Two PQRY-P96THMU-A
Minimum Circuit Ampacity MCA 23/21 - 23/21 Ampere *3
Maximum fuse size (time delay) MOCP 40/30 -40/30 Ampere *3
Recommended Fuse/Breaker Size 23/21 - 23/21 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 6.2 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 52 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~48
Refrigerant Pipe Dimensions Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) - / 7/8 Inch (22.2 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 + 25.4 GPM (5.76 + 5.76m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 GPM (4.5 + 4.5 ~ 7.2 + 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Protection Device Compressor Over-heat protection
External Finish Acrylic painted steel plate
Pipe between unit and distributor Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 192600 Btu/h (56.4 kW) *1
Cooling Power Input (Nominal) 11.89 kW *3
Cooling Current Input (Nominal) 16.7 Ampere *3
Heating Capacity (Nominal) 216000 Btu/h (63.3 kW) *3
Heating Power Input (Nominal) 12.74 kW *3
Heating Current Input (Nominal) 17.7 Ampere *3
Set Model With Two PQRY-P96YHMU-A
Minimum Circuit Ampacity MCA 11 - 11 Ampere *3
Maximum fuse size (time delay) MOCP 15 - 15 Ampere *3
Recommended Fuse/Breaker Size 11 - 11 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 6.3 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 52 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~48
Refrigerant Pipe Dimensions Liquid (High Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Circulating Water Water Flow Rate 25.4 + 25.4 GPM (5.76 + 5.76m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 GPM (4.5 + 4.5 ~ 7.2 + 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Pipe between unit and distributor Gas (Low Pressure mm) 3/4 (19.05 mm) Brazed

Power Source Voltage, Phase, Cycle 208/230V, 3-phase, 60Hz
Cooling Capacity (Nominal) 216000 Btu/h (63.3 kW) *1
Cooling Power Input (Nominal) 13.9 kW *3
Cooling Current Input (Nominal) 42.8-38.7 Ampere *3
Heating Capacity (Nominal) 243000 Btu/h (71.2 kW) *3
Heating Power Input (Nominal) 14.22 kW *3
Heating Current Input (Nominal) 43.9-39.7 Ampere *3
Set Model With One PQRY-P120THMU-A / and One PQRY-P96THMU-A
Minimum Circuit Ampacity MCA 30/27 - 23/21 Ampere *3
Maximum fuse size (time delay) MOCP 50/40 - 40/30 Ampere *3
Recommended Fuse/Breaker Size 30/27-23/21 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor /
Compressor Lubricant MEL32 / MEL32
Compressor Crankcase Heater 0.051 (230V) / 0.051 (230V)
Compressor Motor Output 8.5 / 6.3 kW
Compressor Starting method Inverter / Inverter
Sound Pressure Level (measured in anechoic room) 53 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches / 43-5/16 Inches (551/551 mm )
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 2~50 (Connectable branch pipe number is max 48.)
Refrigerant Pipe Dimensions Liquid (High Pressure) 1-1/8 Inches (28.58 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters) / 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 + 25.4 / GPM (5.76 + 5.76 / m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 / GPM (4.5 + 4.5 ~ 7.2 + 7.2 / m³/h)
Circulating Water Pressure Drop 17 / 17 kPa (2.47 / 2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection /
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) /
Protection Device Compressor Over-heat protection /
External Finish Acrylic painted steel plate
Pipe between unit and distributor Gas (Low Pressure mm) 3/4 (19.05 mm) Brazed / 3/4 (19.05 mm) Brazed

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 216000 Btu/h (63.3 kW) *1
Cooling Power Input (Nominal) 13.9 kW *3
Cooling Current Input (Nominal) 19.3 Ampere *3
Heating Capacity (Nominal) 243000 Btu/h (71.2 kW) *3
Heating Power Input (Nominal) 14.22 kW *3
Heating Current Input (Nominal) 19.8 Ampere *3
Set Model With One PQRY-P120YHMU-A / and One PQRY-P96YHMU-A
Minimum Circuit Ampacity MCA 14 - 11 Ampere *3
Maximum fuse size (time delay) MOCP 20 - 15 Ampere *3
Recommended Fuse/Breaker Size 14 - 11 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor /
Compressor Lubricant MEL32 / MEL32
Compressor Crankcase Heater 0.051 (230V) / 0.051 (230V)
Compressor Motor Output 8.5 / 6.3 kW
Compressor Starting method Inverter / Inverter
Sound Pressure Level (measured in anechoic room) 53 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm))
Dimensions H x W x D Depth 21-11/16 Inches / 43-5/16 Inches (551/551 mm )
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 2~50 (Connectable branch pipe number is max 48.)
Refrigerant Pipe Dimensions Liquid (High Pressure) 1-1/8 Inches (28.58 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters) / 1.32 Gallons (5 Liters)
Circulating Water Water Flow Rate 25.4 + 25.4 / GPM (5.76 + 5.76 / m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 / GPM (4.5 + 4.5 ~ 7.2 + 7.2 / m³/h)
Circulating Water Pressure Drop 17 / 17 kPa (2.47 / 2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection /
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) /
Protection Device Compressor Over-heat protection /
Pipe between unit and distributor Gas (Low Pressure mm) 3/4 (19.05 mm) Brazed / 3/4 (19.05 mm) Brazed
External Finish Acrylic painted steel plate

Power Source Voltage, Phase, Cycle 208/230V, 3-phase, 60Hz
Cooling Capacity (Nominal) 240000 Btu/h (70.3 kW) *1
Cooling Power Input (Nominal) 15.93 kW *3
Cooling Current Input (Nominal) 48.7-44.0 Ampere *3
Heating Capacity (Nominal) 270000 Btu/h (79.1 kW) *3
Heating Power Input (Nominal) 15.7 kW *3
Heating Current Input (Nominal) 48.4-43.8 Ampere *3
Set Model With Two PQRY-P120THMU-A
Minimum Circuit Ampacity MCA 30/27 - 30/27 Ampere *3
Maximum fuse size (time delay) MOCP 50/40 - 50/40 Ampere *3
Recommended Fuse/Breaker Size 30/27 - 30/27 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 8.5 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 54 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm )
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 2~50 (Connectable branch pipe number is max 48.)
Refrigerant Pipe Dimensions Liquid (High Pressure) 1-1/8 Inches (28.58 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 + 25.4 GPM (5.76 + 5.76m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 GPM (4.5 + 4.5 ~ 7.2 + 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Pipe between unit and distributor Gas (Low Pressure mm) -
Pipe between unit and distributor Liquid (High Pressure) 3/4 (19.05 mm) Brazed
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 240000 Btu/h (70.3 kW) *1
Cooling Power Input (Nominal) 15.93 kW *3
Cooling Current Input (Nominal) 22 Ampere *3
Heating Capacity (Nominal) 270000 Btu/h (79.1 kW) *3
Heating Power Input (Nominal) 15.7 kW *3
Heating Current Input (Nominal) 21.8 Ampere *3
Set Model With Two PQRY-P120YHMU-A
Minimum Circuit Ampacity MCA 14 - 14 Ampere *3
Maximum fuse size (time delay) MOCP 20 - 20 Ampere *3
Recommended Fuse/Breaker Size 14-14 Ampere *3
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 8.5 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 54 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heat source unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 2~50 (Connectable branch pipe number is max 48.)
Refrigerant Pipe Dimensions Liquid (High Pressure) 1-1/8 Inches (28.58 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 1-1/8 Inches (28.58 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Circulating Water Water Flow Rate 25.4 + 25.4 GPM (5.76 + 5.76m³/h)
Circulating Water Operation Volume Range 19.8 + 19.8 ~ 31.7 + 31.7 GPM (4.5 + 4.5 ~ 7.2 + 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Pipe between unit and distributor Gas (Low Pressure mm) 3/4 (19.05 mm) Brazed

Power Source Voltage, Phase, Cycle 208/230V, 3-phase, 60Hz
Cooling Capacity (Nominal) 72700 Btu/h (21.3 kW) *1
Cooling Power Input (Nominal) 3.97 kW *1
Cooling Current Input (Nominal) 12.6-11.4 Ampere *1
Heating Capacity (Nominal) 80000 Btu/h (23.4 kW) *1
Heating Power Input (Nominal) 3.83 kW *1
Heating Current Input (Nominal) 11.8-10.7 Ampere *1
Minimum Circuit Ampacity MCA 16/15 Ampere
Maximum fuse size (time delay) MOCP 25/20 Ampere
Recommended Fuse/Breaker Size 16/15 Ampere
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Lubricant MEL32
Compressor Crankcase Heater 0.051 (230V)
Compressor Motor Output 4.5 kW
Compressor Starting method Inverter
Sound Pressure Level (measured in anechoic room) 47 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heatsource unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~18
Refrigerant Pipe Dimensions Liquid (High Pressure) 5/8 Inch (15.88 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 3/4 Inch (19.05 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 / 290 psi (2 / 2 MPa)
Circulating Water Water Flow Rate 25.4 GPM (5.76m³/h)
Circulating Water Operation Volume Range 19.8 - 31.7 GPM (4.5 - 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Compressor Over-heat protection
External Finish Acrylic painted steel plate

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 72700 Btu/h (21.3 kW) *1
Cooling Power Input (Nominal) 3.97 kW *1
Cooling Current Input (Nominal) 5.7 Ampere *1
Heating Capacity (Nominal) 80000 Btu/h (23.4 kW) *1
Heating Power Input (Nominal) 3.83 kW *1
Heating Current Input (Nominal) 5.3 Ampere *1
Minimum Circuit Ampacity MCA 8 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Recommended Fuse/Breaker Size 8 Ampere
Refrigerant Type R410A
Compressor Type x Quantity Propeller Fan x 1
Compressor Type Inverter scroll hermetic compressor
Compressor Lubricant MEL32
Compressor Crankcase Heater 0.051 (230V)
Compressor Motor Output 4.6 kW
Compressor Starting method Inverter
Sound Pressure Level (measured in anechoic room) 47 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm )
Indoor unit connectable Total capacity 50~150% of heatsource unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~18
Refrigerant Pipe Dimensions Liquid (High Pressure) 5/8 Inch (15.88 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 3/4 Inch (19.05) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 / 290 psi (2 / 2 MPa)
Circulating Water Water Flow Rate 25.4 GPM (5.76m³/h)
Circulating Water Operation Volume Range 19.8 - 31.7 GPM (4.5 - 7.2m³/h)
Circulating Water Max Water Pressure 6 Ft (3psi)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Compressor Over-heat protection
External Finish Acrylic painted steel plate

Power Source Voltage, Phase, Cycle 208 / 230V, 1-phase, 60Hz
Cooling Capacity (Nominal) 96300 Btu/h (28.2 kW) *1
Cooling Power Input (Nominal) 5.77 kW *1
Cooling Current Input (Nominal) 17.9-16.2 Ampere *1
Heating Capacity (Nominal) 108000 Btu/h (31.7 kW) *1
Heating Power Input (Nominal) 6.18 kW *1
Heating Current Input (Nominal) 19.1-17.2 Ampere *1
Minimum Circuit Ampacity MCA 23/21 Ampere
Maximum fuse size (time delay) MOCP 40/30 Ampere
Recommended Fuse/Breaker Size 23/21 Ampere
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 6.2 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 49 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm)
Indoor unit connectable Total capacity 50~150% of heatsource unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~24
Refrigerant Pipe Dimensions Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed
Refrigerant Pipe Dimensions Gas (Low Pressure) 7/8 Inch (22.2 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 GPM (5.76m³/h)
Circulating Water Operation Volume Range 19.8 - 31.7 GPM (4.5 - 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection

Power Source Voltage, Phase, Cycle 460V, 3-phase, 60Hz
Cooling Capacity (Nominal) 96300 Btu/h (28.2 kW) *1
Cooling Power Input (Nominal) 5.77 kW *1
Cooling Current Input (Nominal) 8.1 Ampere *1
Heating Capacity (Nominal) 108000 Btu/h (31.7 kW) *1
Heating Power Input (Nominal) 6.18 kW *1
Heating Current Input (Nominal) 8.6 Ampere *1
Minimum Circuit Ampacity MCA 11 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Recommended Fuse/Breaker Size 11 Ampere
Refrigerant Type R410A
Compressor Type Inverter scroll hermetic compressor
Compressor Starting method Inverter
Compressor Motor Output 6.3 kW
Compressor Crankcase Heater 0.051 (230V)
Compressor Lubricant MEL32
Sound Pressure Level (measured in anechoic room) 49 dB(A)
Dimensions H x W x D Height 43-5/16 Inches (1100 mm)
Dimensions H x W x D Width 34-11/16 Inches (880 mm)
Dimensions H x W x D Depth 21-11/16 Inches (550 mm )
Indoor unit connectable Total capacity 50~150% of heatsource unit capacity
Indoor unit connectable Model (Quantity) P06~P96 / 1~24
Refrigerant Pipe Dimensions Gas (Low Pressure) 7/8 Inch (22.2 mm) Brazed
Refrigerant Pipe Dimensions Liquid (High Pressure) 3/4 Inch (19.05 mm) Brazed
Water volume in plate 1.32 Gallons (5 Liters)
Water pressure Maximum 290 psi (2 MPa)
Circulating Water Water Flow Rate 25.4 GPM (5.76m³/h)
Circulating Water Operation Volume Range 19.8 - 31.7 GPM (4.5 - 7.2m³/h)
Circulating Water Pressure Drop 17 kPa (2.47psi)
Operating Inlet Water Temp. Range Cooling 50° F (10° C) ~ 113° F (45° C) *
Operating Inlet Water Temp. Range Heating 50° F (10° C) ~ 113° F (45° C) *
Operating Temperature Range Cooling (Outdoor) 59~75° F (15~24° C) D.B.
Operating Temperature Range Heating (Outdoor) 59~81° F (15~27° C) D.B.
External Finish Acrylic painted steel plate
Protection Device Compressor Over-heat protection
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com

Sweets app for Revit – Learn More