P-Series Heat Pumps - Indoor Units_PVA Series Model Number: #PVA-A36AA4/PUZ-HA36NHA4 Normal 0 false false false EN-US JA X-NONE MicrosoftInternetExplorer4 Features One inch foam R4.2 insulation provides remarkable resistance to condensation and strong performance in a wide range of environments....


MasterFormat: Decentralized HVAC Equipment | Decentralized Unitary HVAC Equipment



Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



P-Series Heat Pumps - Indoor Units_PVA Series - PVA-A36AA4/PUZ-HA36NHA4

P-Series Heat Pumps - Indoor Units_PVA Series


Model Number: #PVA-A36AA4/PUZ-HA36NHA4

Normal 0 false false false EN-US JA X-NONE MicrosoftInternetExplorer4


Features
  • One inch foam R4.2 insulation provides remarkable resistance to condensation and strong performance in a wide range of environments.
  • Quality constructed cabinet composed of slate gray, powder-coated G60 sheet metal.
  • Unique blow through design provides an easy coil cleaning when blower is removed.
  • Multi-position design allows for various applications and requires no additional kits, including down-flow configuration.
  • Can be fully disassembled and reassembled, allowing an easy fit in closets, attics, equipment rooms and numerous other tight spaces.
  • Quiet operation using a highly efficient, variable speed DC motor with forward curved blower providing constant comfort.
  • RoHS compliant, fiberglass-free insulation that is environmentally friendly.
  • Less than 1% air leakage for a higher standard of Indoor Air Quality.


Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 35000 Btu/h (10.26 kW) *1
Cooling Capacity Range 12000 - 35000 Btu/h (3.5 - 10.3 kW)
Cooling Total Input 4850 W (4.900 kW)
Cooling Energy Efficiency SEER 17.8
Cooling Sensible Heat Factor 0.75
Cooling EER 12.2
Cooling Moisture Removal Pints/H 7.9
Heating at 47° F Rated Capacity 32000 Btu/h (9.37 kW) *2
Heating at 47° F Capacity Range 12000 - 38000 (3.5 - 11.1 kW)
Heating at 47° F Total Input 2990 W
Heating at 47° F HSPF (Region IV) 9.8
Heating at 47° F COP 3.2 Btu/Btu
Heating at 17° F COP 2.6 Btu/Btu
Heating at 17° F Rated Capacity 25000 Btu/h (7.3 kW) *3
Heating at 17° F Total Input 2810 kW
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Charge 3.0 [6 lbs 10oz]
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 244 W
Fan Fan Motor - F.L.A. 2.64 F.L.A
External Static Pressure 0.02 -0.06-0.14 -0.20 In. WG (5 -15-35 -50 Pa)
Airflow Cooling : DRY 847-1024-1201 CFM (24-29-34 m³/min)
Airflow Cooling : WET 777-953-1130 CFM (22-27-32 m³/min)
Sound Pressure Level Cooling 33-38-42 dB(A)
Dimensions H x W x D Height 9-7/8 Inches (250 mm)
Dimensions H x W x D Width 55-1/8 Inches (1400 mm)
Dimensions H x W x D Depth 28-7/8 Inches (732 mm)
Field Drainpipe Size O.D. 1-9/32 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB, 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F (-18°C) DB **
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Voltage Indoor - Outdoor S2-S3 DC24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Galvanized