P-Series Heat Pumps - Indoor Units_PKA Model Number: #PKA-A36KA6/PUZ-HA36NHA4 Wall-mounted ductless indoor unit for residential and light commercial applications. Ideal for applications such as churches, classrooms, daycare centers, small offices, and more. Rated capacities range from 12,000 -...


MasterFormat: Decentralized HVAC Equipment | Decentralized Unitary HVAC Equipment



Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



P-Series Heat Pumps - Indoor Units_PKA - PKA-A36KA6/PUZ-HA36NHA4

P-Series Heat Pumps - Indoor Units_PKA


Model Number: #PKA-A36KA6/PUZ-HA36NHA4

Wall-mounted ductless indoor unit for residential and light commercial applications. Ideal for applications such as churches, classrooms, daycare centers, small offices, and more. Rated capacities range from 12,000 - 34,200 Btu/h.


Features
  • Shiny-white–exterior plastic
  • Sleek, slim-line design
  • Ductless installation
  • RedLINK enabled for wall-mounted wireless, hand-held wireless or wired controller
  • Easy-clean, washable filter
  • Wide air flow pattern for better air distribution; independently adjustable vanes
  • Optional i-see sensor for improved temperature sensing
  • Self-check function—integrated diagnostics
  • Hot-start technology
  • Limited warranty: five years on parts and defects and seven years on compressors


Energy Star System X
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *5
Cooling Rated Capacity 33500 Btu/h (9.82 kW) *1
Cooling Capacity Range 18000 - 34200 Btu/h (5.3 - 10 kW)
Cooling Total Input 2790 W (2.800 kW)
Cooling Energy Efficiency SEER 16.2
Cooling Sensible Heat Factor 0.71
Cooling Moisture Removal Pints/H 8.7
Cooling EER 12
Heating at 47° F Rated Capacity 38000 Btu/h (11.1 kW) *2
Heating at 47° F Capacity Range 18000 - 40000 Btu/h (5.3 - 11.7 kW)
Heating at 47° F Total Input 3410 W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 3.27 Btu/Btu
Heating at 17° F Maximum Capacity 38000 Btu/h (11.1 kW)
Heating at 17° F COP 2.2 Btu/Btu
Heating at 17° F Rated Capacity 25000 Btu/h (7.3 kW) *3
Heating at 17° F Total Input 3330 W
Heating at 5° F Maximum Capacity 38000 Btu/h (4.8 kW)
Heating at 5° F COP 1.64 Btu/Btu
Heating at 5° F Total Input 6,760
Minimum Circuit Ampacity MCA 1 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 1.4 (FV50S) [45]
Refrigerant Charge 5.5 [12 lbs]
Refrigerant Control Electronic Expansion Valve
Fan Fan motor output - kW 56
Fan Fan Motor - F.L.A. 0.57 F.L.A
External Static Pressure 0 in.WG (0 Pa)
Airflow DRY 705-810-920 CFM (20-23-26 m³/min)
Airflow WET 635-730-830 (18-21-23 m³/min)
Airflow Cooling 1730 CFM (49 m³/min)
Sound Pressure Level 43-46-49 dB(A)
Dimensions H x W x D Height 14-3/8 Inches (365 mm)
Dimensions H x W x D Width 46-1/16 Inches (1,170 mm)
Dimensions H x W x D Depth 11-5/8 Inches (295 mm)
Field Drainpipe Size O.D. 5/8 Inch (16 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 66°F (19°C) DB, 59°F (15°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 83°F (28°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 63°F (17°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 83°F (28°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB, 59°F (15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB, -13°F (-25°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 59°F (15°C) WB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V