Mitsubishi Electric HVAC - P-Series Heat Pumps - Indoor Units_PKA-PKA-A30KA6/PUZ-A30NHA6

P-Series Heat Pumps - Indoor Units_PKA Model Number: #PKA-A30KA6/PUZ-A30NHA6 Wall-mounted ductless indoor unit for residential and light commercial applications. Ideal for applications such as churches, classrooms, daycare centers, small offices, and more. Rated capacities range from 12,000 -...


MasterFormat: Decentralized HVAC Equipment | Decentralized Unitary HVAC Equipment



Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



P-Series Heat Pumps - Indoor Units_PKA - PKA-A30KA6/PUZ-A30NHA6

P-Series Heat Pumps - Indoor Units_PKA


Model Number: #PKA-A30KA6/PUZ-A30NHA6

Wall-mounted ductless indoor unit for residential and light commercial applications. Ideal for applications such as churches, classrooms, daycare centers, small offices, and more. Rated capacities range from 12,000 - 34,200 Btu/h.


Features
  • Shiny-white–exterior plastic
  • Sleek, slim-line design
  • Ductless installation
  • RedLINK enabled for wall-mounted wireless, hand-held wireless or wired controller
  • Easy-clean, washable filter
  • Wide air flow pattern for better air distribution; independently adjustable vanes
  • Optional i-see sensor for improved temperature sensing
  • Self-check function—integrated diagnostics
  • Hot-start technology
  • Limited warranty: five years on parts and defects and seven years on compressors


Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 30000 Btu/h (8.79 kW) *1
Cooling Capacity Range 12000 - 30000 BTU/h (3.5 - 8.8 kW)
Cooling Total Input 4130 W (4.100 kW)
Cooling Energy Efficiency SEER 15.5
Cooling Sensible Heat Factor 0.7
Cooling EER 7.3
Cooling Moisture Removal Pints/H 8.1
Heating at 47° F Rated Capacity 32000 Btu/h (9.4 kW) *2
Heating at 47° F Capacity Range 12000 - 34000 Btu/h (3.5 - 10 kW)
Heating at 47° F Total Input 3150 W
Heating at 47° F HSPF (Region IV) 8.9
Heating at 47° F COP 2.9 Btu/Btu
Heating at 17° F COP 2.2 Btu/Btu
Heating at 17° F Rated Capacity 23000 Btu/h (6.7 kW) *3
Heating at 17° F Total Input 2850 W
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 30 Ampere
Refrigerant Type R410A
Refrigerant Oil Type 0.87 (FV50S) [28]
Refrigerant Charge 3.0 [6 lbs 10 oz]
Refrigerant Control Linear Expansion Valve
Fan Fan motor output - kW 56 W
Fan Fan Motor - F.L.A. 0.036 F.L.A
External Static Pressure 0
Airflow Cooling : DRY 635-705-775 CFM (18-20-22 m³/min)
Airflow Cooling : WET 570-635-700 CFM (16-18-20 m³/min)
Sound Pressure Level 39-42-45 dB(A)
Dimensions H x W x D Height 37-1/8 Inches (943 mm)
Dimensions H x W x D Width 37-3/8 Inches (950 mm)
Dimensions H x W x D Depth 13 + 7/8 Inches (330 + 23 mm)
Field Drainpipe Size O.D. 5/8 Inch (16 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 95°F (35°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 71°F (22°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 70°F (21°C) DB, 59°F (15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB 12°F (-11°C) DB, 10°F (-12°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 0°F** (-18°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 70°F (21°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 59°F (15°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB 12°F (-11°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB 10°F (-12°C) WB
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
Voltage Indoor - Outdoor S2-S3 DC24V

Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee,  GA USA 30024 
Tel: (800) 687-1966
Fax: (800) 658-1458
Website: http://www.mehvac.com