Overview



M-Series Heat Pumps - Indoor Units (Multi Zone)_MSZ - MSZ-FE18NA

M-Series Heat Pumps - Indoor Units (Multi Zone)_MSZ


Model Number: #MSZ-FE18NA

Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEV's provide higher efficiency with controlled power usage. The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restored when power returns.


Features
  • Sleek, flat panel design
  • Hot-start technology
  • Quiet operation
  • i-see Sensor technology available
  • Enhanced filtration system available
  • Hand-held wireless remote; optional MHK1 backlit wall-mounted wireless remote controller


Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 18000 Btu/h (5.28 kW) *1
Cooling Capacity Range 8200 - 25200 Btu/h (2.4 - 7.4 kW)
Cooling Total Input 1270 W (1.3 kW)
Cooling Energy Efficiency SEER 20.2
Cooling Sensible Heat Factor 0.84
Cooling Moisture Removal Pints/H 2.7
Cooling EER 14.2
Heating at 47° F Rated Capacity 21600 Btu/h (6.3 kW) *2
Heating at 47° F Capacity Range 7500 - 29700 Btu/h (2.2 - 8.7 kW)
Heating at 47° F Total Input 1540 (520 - 2240) W
Heating at 47° F HSPF (Region IV) 10.5
Heating at 47° F COP 4.11
Heating at 17° F Maximum Capacity 21600 Btu/h (6.3 kW)
Heating at 17° F COP 2.76 Btu/Btu
Heating at 17° F Rated Capacity 11700 Btu/h (3.4 kW) *3
Heating at 17° F Total Input 1240 W
Heating at 5° F Maximum Capacity 21600 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 20 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 162-226-381-410 CFM (4-6-10-11 m³/min)
Airflow Cooling : WET 144-202-350-367CFM (4-6-10-10 m³/min)
Airflow Heating : WET 166-240-399-420 CFM (5-7-11-12 m³/min)
Sound Pressure Level Cooling 22-33-43-45 dB(A)
Sound Pressure Level Heating 22-33-43-44 dB(A)
Dimensions H x W x D Height 12-13/16 Inches (325 mm)
Dimensions H x W x D Width 43-5/16 Inches (1,116 mm)
Dimensions H x W x D Depth 9-3/8 Inches (238 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 5/8 Inch (16 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 3/8 Inch (9.52 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB, -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -13°F (-25°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Defrost Method Reverse Cycle
External Finish Munsell 1.0Y 9.2 / 0.2
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V